20304949
"Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire
4
MAkE SURE YOU HAVE RECEIVED ALL
PARTS:
Check your packing list to verify that all listed parts have
been received. You should have the following:
BURNER - GRATE ASSEMBLY 24/18
•
Burner and Grate Weldment Assembly
•
Lava Rocks (2)
•
Glowing Embers (Rock Wool)
•
Damper Clamp
•
Installation /Operating Instructions
•
Masonry Screws (2)
•
3/8" Aluminum tube with 3/8" 90° elbow, 1/2" to 3/8"
tube fitting
CERAMIC FIBER OR REFRACTORY CE-
MENT LOGS 24/18
•
Individual Logs
•
Installation Instructions
Carefully inspect the contents for shipping damage. If any
parts are missing or damaged, immediately inform the
dealer from whom you purchased the appliance.
Do not
attempt to install any part of the appliance unless you
have all parts in good condition.
ITEMS REQUIRED FOR INSTALLATION
Ensure that the following items are available before pro-
ceeding with installation:
•
External regulator (for propane/L.P.G. only)
•
Manual shutoff valve
•
Piping which complies with local codes
•
Pipe wrench
•
Tee joint
•
Pipe sealant approved for use with propane/L.P.G.
(Resistant to sulfur compounds)
•
Drill with masonry bit (for mounting to the floor)
FEATURES & SPECIFICATIONS
GAS PRESSURES
Natural *Propane (LP)
Inlet Minimum
6.0” w.c.
11.0” w.c.
Inlet Maximum
10.5” w.c.
13.0” w.c.
Regulator Pressure
4.0” w.c.
10.0” w.c.
*NOTE:
An external regulator is required to reduce supply pres-
sure to a maximum of 13” w.c.
CAUTION
•
Handle the gas log burner assembly by
the grate only. Do not pick the unit up by
the burner.
•
Gloves are recommended when handling
ceramic fiber logs to prevent skin irritation
from loose fibers. Logs are fragile —
handle with care.
GAS SPECIFICATIONS
Gas Rate
Min. Input
Model
Fuel
Control
BTU/h
VDY24/18NVP Nat. Millivolt (thermopile)
50,000
VDY24/18PVP
LP Millivolt (thermopile)
50,000
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of
matches or batteries.
Millivolt control with pilot has three (3) positions:
OFF
- All gas to the gas logs is shut off at the valve.
IGN
- Valve position to light/maintain a standing pilot.
ON
- Valve position to light/maintain the gas burner.