1.  The  installation,  combustion  and  ventilation  air 

must conform with local codes or, in the absence of 

local codes, with the National Fuel Gas Code, ANSI 

Z223.1.

2.  This unit complies with 

ANSI Z21.60 • CSA 2.26

 Dec-

orative  Gas Appliance  for  Installation  in  Solid-Fuel 

Burning Fireplace. 

3.  Installation and repair should be done by a qualified 

service person. Vermont Castings Group Vented Gas 

Logs must be installed only in a solid-fuel (wood) burn-

ing fireplace which can only be constructed of non-com-

bustible material, with minimum venting requirements, 

see installation section.

4.  To prevent malfunction, gas log set and flue should 

be cleaned at least annually by a professional service 

person.  More frequent cleaning may be required due 

to excessive lint from carpeting, etc. It is imperative 

that control compartments, burners and circulating air 

passageways be kept clean.

5.  Correct  installation  of  the  ceramic  fiber  logs,  and 

annual cleaning are necessary to minimize problems 

with sooting. See log placement instructions for proper 

installation.

6.  A damper clamp must be installed to provide the min-

imum permanent vent opening to vent flue products, 

See installation instructions.

7.  Never burn solid fuels in a fireplace where a gas log 

set is installed.

8. 

This appliance must not be used with glass doors 

in the closed position. 

Provisions for adequate com-

bustion air must be provided, adequate combustion air 

usually results in all flames curling into the fireplace 

away from screen and up the flue.

9.  Keep  room  area  clear  and  free  from  combustible 

materials, gasoline and other flammable vapors and 

liquids.

10. Children and adults should be alerted to the hazard 

of high surface temperature and should stay away to 

avoid burns or clothing ignition.

11.  Young children should be carefully supervised when 

they are in the same room with the gas log set in opera-

tion.

IMPORTANT SAFETY INFORMATION

12. Do not place clothing or other flammable material near 

the fireplace when the gas logs are in use.

13. Do not use this gas log set if any part has been under-

water.  Immediately call a qualified service technician 

to inspect the gas logs and replace any part of the 

control system and any gas control which has been 

under water.

14. The gas log set and its individual shutoff valve must be 

disconnected from the gas supply piping system during 

any pressure testing of the gas supply piping system 

at test pressures in excess of 1/2 psig (3.5kPa).

15. The gas log set must be isolated from the gas supply 

piping system by closing its individual manual shutoff 

valve during any pressure testing of the gas supply 

piping system at test pressures equal to or less than 

1/2 psig (3.5kPa).

16.

 FOR MASSACHUSETTS RESIDENTS ONLY:

   

Installation of this vented gas log in the Commonwealth 

of Massachusetts requires the damper be permanently 

removed or welded in the full open position. In addi-

tion, a naturally vented gas log may not be installed 

in a bedroom or bathroom in the commonwealth of 

Massachusetts. 

INSTALLER

Please leave these instructions with the appliance.

OWNER

Please retain these instructions for future reference.

W

ARNING

  Any  change  to  this  gas  log  set  or  its 

controls can be dangerous.

  Improper  installation  or  use  of  the  gas 

log set can cause serious injury or death 

from  fire,  burns,  explosion  or  carbon 

monoxide poisoning.

IMPORT

ANT

Read these instructions carefully before 

installing or trying to operate this vent-free 

gas heater.

W

ARNING

This  appliance  is  for  installation  only  in 

a  solid  fuel  burning  fireplace  (masonry 

fireplace or manufactured fireplace)

Nous recommandons que nos 
appareils de chauffage au gaz 
soient installés et entretenus par 
des professionnels qui ont été 
accrédités aux È.U. par le National 
Fireplace Institute ® (NFI) comme 
étant des spécialistes du NFI en 
matièred’appareils de chauffage 
au gaz.

Содержание DUZY VDY24/18

Страница 1: ...e Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your ga...

Страница 2: ...r Placement 12 Decorative Volcanic Rock Placement 12 Fireplace Draft Test 12 contents Flame Appearance 13 Initial Startup 13 Operating Instructions 14 For Your Safety Read Before Lighting 14 Millivolt...

Страница 3: ...zard of high surface temperature and should stay away to avoid burns or clothing ignition 11 Young children should be carefully supervised when they are in the same room with the gas log set in opera...

Страница 4: ...hutoff valve Piping which complies with local codes Pipe wrench Tee joint Pipe sealant approved for use with propane L P G Resistant to sulfur compounds Drill with masonry bit for mounting to the floo...

Страница 5: ...re of the fireplace damper blade and provide a minimum flue opening per table below Should the clamp not fit or provide the required permanent opening from the table have the damper blade cut to pro v...

Страница 6: ...in the homeowner s manual must not be exceeded NOTE If the log set is equipped with a remote receiver a restrictive barrier may reduce the battery life by increasing the ambient temperature inside th...

Страница 7: ...pe Internally tinned copper or copper tubing can be used per National Fuel Code section 2 6 3 providing gas meets hydrogen sulfide limits and where permitted by local codes Gas piping system must be s...

Страница 8: ...cause improper and dan gerous operation Verify proper operation after servicing WARNING The Millivolt thermopile is a self powered combination gas control that does not require 110VAC to operate See F...

Страница 9: ...k covering The remote receiver is attached but does not physi cally fit inside the fireplace with 2 clearance to the side wall install remote receiver Connect wires according to remote receiver instru...

Страница 10: ...e 8 LG1000 VDY2418D5 BACK LOG Back Log 1 LG1000 Figure 9 LG1001 VDY2418D5 bottom logs Bottom Left Log 3 Bottom Right Log 2 LG1001 Figure 10 2 Placed bottom right log 2 on right side of grate Figure 10...

Страница 11: ...d middle right log Figure 11 5 Place middle right log 5 on top of bottom right log Figure 11 6 Rest top right log 6 on back log and bottom right log Figure 12 7 Place top left log 7 on bottom left log...

Страница 12: ...is important to periodically clean and inspect the logs per the cleaning and ser vicing section of the manual FIREPLACE DRAFT TEST FIREPLACE DRAFT TEST METHOD To determine if your fireplace is draftin...

Страница 13: ...pilot flame must always be present when appliance is in operation It should touch the thermocouple or ther mopile body Initial Startup During manufacturing fabricating and shipping various components...

Страница 14: ...pplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never...

Страница 15: ...ntrol knob in for a further 60 seconds to prevent the flame detector from shut ting off the gas while the probe is warming up Release the control knob 9 Turn gas control knob counterclockwise to the O...

Страница 16: ...lure to keep air intake holes clean will result in sooting and poor combustion If embers rock wool have turned a rust color and become brittle remove old embers rock wool from log set Replace with new...

Страница 17: ...2 Pilot is partially clogged 3 Defective thermopile 1 Gas leak 2 Control valve defective 1 Gas supply turned off or manual shutoff valve closed 2 Control knob not in PILOT position 3 Control knob not...

Страница 18: ...s clogged or dam aged 2 Burner is damaged 3 Gas regulator is defective 1 Vapors from paint or curing process of logs 1 Turning control knob to HIGH posi tion when burner is cold 2 Air in gas line 3 Di...

Страница 19: ...07 2 Control Knob 18D0603 18D0603 3 Millivolt Control Valve w Pilot 27D8006 27D8005 4 Pilot 27D8974 27D8973 5 Thermocouple Thermopile 28D0566 28D0566 ACCESSORIES Flex Connector Flexcon30 Wall Kit Swit...

Страница 20: ...2418D5 logs REPLACEMENT PARTS DUZY V LOG SERIES Ref Description Qty VDY24 18D5 1 Back Log 1 32D3121 2 Bottom Right Log 1 32D3122 3 Bottom Left Log 1 32D3123 4 Middle Left Log 1 32D3124 5 Middle Right...

Страница 21: ...21 Duzy Gas Log Sets The Look and Feel of a Real Wood Fire 20304949...

Страница 22: ...days to comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents...

Страница 23: ...s The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox b...

Страница 24: ...Technical Service Costco Bilingual 1 800 463 3783 Vermont Castings Group 1 866 500 5670 Vermont Castings Group 149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgroup com...

Отзывы: