Replacing or Servicing Damper Tabs and Torsion Bar Clip
Tools Required
•
Ratchet Handle, ¼” drive
•
7/16” Socket, ¼” drive
•
2” Extension, ¼” drive
•
Screwdriver, Phillips, # 2 tip
•
7/16” Combination Wrench (box and open)
STEP 1:
Remove the flue collar.
STEP 2:
Replace and/or service the damper tabs and torsion bar clip. Reassemble
and check damper operation for a good damper seal and ease of
movement.
STEP 3:
Replace the flue collar. If the flue collar gasket is dried out and/or
compressed to the point where metal to metal contact is noted between the
flue collar and the stove back, replace the flue collar gasket. Refer to the
gasketing section of this manual for instructions.
Replacing or Servicing the Refractory Assembly
Tools Required
•
7/16” Combination Wrench (box
& open)
•
Cold Chisel, ½”
•
Hammer, Ball Peen, 12 oz.
•
Caulking Gun Frame
•
Thermocement, 11 oz. tube
•
Masking Tape
•
Tape Measure, 6”
•
Shears, 10”- 12”
•
Safety Goggles
STEP 1:
Remove the 6 screws that fasten the stove back to the right and left stove
ends.
STEP 2:
Tap the cold chisel into the seam where the bottom flange of the stove
back joins the stove bottom to break the cement seal.
STEP 3:
Lift the stove back up out of its cement groove in the stove bottom and
pull the back from the stove, bottom first.
STEP 4:
Replace and/or replace service the refractory package, catalyst block, heat
exchanger, heat deflectors and refractory cover. Clean the catalyst block
and refractory package with low pressure air.
STEP 5:
Reassemble the refractory assembly. Tape the heat exchanger, catalyst
block access panel and refractory cover in place with masking tape.