STLDV FRAMING
INSTALLATION INFORMATION
8
20306750
Designer Series Direct Vent Gas Fireplace
48
³⁄₁₆
”
(1224 mm)
CL
27
³⁄₈
” (695
mm)
50
¹⁄₁₆
” (1272
mm)
23" (1/2" Drywall)
or Adjustable to
22
³⁄₄
” (5/8” Drywall)
FP2848
See thru framing
22
¹¹⁄₁₆
” (576
mm)
8
¹¹⁄₁₆
”
(221
mm)
Min.
7”
(178
mm)
Min.
4”
(102
mm)
Min.
Remove box and
Insulation for Top
Vent Configurations
Noncombustible
Material
Fold Outer Tabs
and Nail to Framing
Members
If using 5/8" drywall, remove
framing tabs and re-install
on 2nd set of holes
positioned slightly inwards
Figure 5 -
STLDV (See-thru) Framing
If using 5/8" drywall, remove
noncombustible supports,
rotate 180° and reinstall to
achieve 5/8" depth
The fireplace must be secured to the floor and/or to framing
studs as shown in
Figure 5
. Use four (4) wood screws or
masonry/ concrete screws to secure fireplace to the floor.
Use four (4) screws to attach fireplace to framing. The side
brackets or nailing flanges are designed to accommodate
two wall boards thicknesses, 1/2" or 5/8".
NOTE
Never install combustible materials over
front face of fireplace.
NOTE
The area above and on the sides of the
fireplace must be a noncombustible material.
Figures 5, 6, 7
NOTE:
Glass cen-
terline is off center
from rought framing
dimensions.