background image

20306750

3

Designer Series Direct Vent Gas Fireplace

4.   Never install the fireplace 

 

•  

in a recreational vehicle

 

•  

where curtains, furniture, clothing, or other flam

-

mable objects are less than 42" from the front, top, 

or sides of the fireplace

 

•  

in high traffic areas

 

•  

in windy or drafty areas 

5.  This fireplace reaches high temperatures. Keep children 

and adults away from hot surfaces to avoid burns or 

clothing ignition. Fireplace will remain hot for a time after 

shutdown. Allow surfaces to cool before touching. 

6.  Young children should be carefully supervised when 

they are in the same room as the appliance. Toddlers, 

young children and others may be susceptible to acci-

dental contact burns. A physical barrier is recommended 

if there are at risk individuals in the house. To restrict 

access  to  a  fireplace  or  stove,  install  an  adjustable 

safety gate to keep toddlers, young children and other 

at risk individuals out of the room and away from hot 

surfaces. 

7.  Do not modify fireplace under any circumstances. Any 

parts removed for servicing must be replaced prior to 

operating fireplace. 

8.  Turn fireplace off and let cool before servicing, install

-

ing, or repairing. Only a qualified service person should 

install,  service,  or  repair  the  fireplace.  Have  burner 

system inspected annually by a qualified service 

person. 

9.  You must keep control compartments, burners, and 

circulating air passages clean. More frequent cleaning 

may be needed due to excessive lint and dust. Turn off 

the gas valve and pilot light before cleaning fireplace. 

10. Have venting system inspected annually by a qualified 

service person. If needed, have venting system cleaned 

or repaired. Refer to 

Cleaning and Maintenance

Page 

48.

11.  Keep the area around your fireplace clear of combus

-

tible materials, gasoline, and other flammable vapor and 

liquids. Do not run fireplace where these are used or 

stored. Do not place items such as clothing or decora-

tions on or around fireplace. 

INSTALLER

Please leave these instructions with the appliance.

OWNER

Please retain these instructions for future reference.

IMPORTANT SAFETY INFORMATION

This fireplace is a vented product. This fireplace must be 

properly installed by a qualified service person. The glass 

door must be properly seated and sealed. If this unit is not 

properly installed by a qualified service person with glass 

door properly seated and sealed, combustion leakage can 

occur. 

CARBON MONOXIDE POISONING:

 Early signs of carbon 

monoxide poisoning are similar to the flu with headaches, 

dizziness and/or nausea. If you have these signs, the fire

-

place may not have been installed properly. Get fresh air 

at once! Have the fireplace inspected and serviced by a 

qualified service person. Some people are more affected 

by carbon monoxide than others. These include pregnant 

women,  people  with  heart  or  lung  disease  or  anemia, 

those  under  the  influence  of  alcohol,  and  those  at  high 

altitudes. 
Propane/LP gas and natural gas are both odorless. An 

odor-making agent is added to each of these gases. The 

odor helps you detect a gas leak. However, the odor added 

to these gases can fade. Gas may be present even though 

no odor exists.

Make certain you read and understand all warnings. Keep 

this manual for reference. It is your guide to safe and proper 

operation of this fireplace.
1.  This  appliance  is  only  for  use  with  the  type  of  gas 

indicated on the rating plate. This appliance is not 

convertible for use with other gases unless a certified 

kit is used. 

2.  For  propane/LP  fireplace,  do  not  place  propane/LP 

supply tank(s) inside any structure. Locate propane/LP 

supply tank(s) outdoors. To prevent performance prob-

lems, do not use propane/LP fuel tank of less than 100 

lbs. capacity. 

3.  If you smell gas

  shut off gas supply.

  do not try to light any appliance.

•  

do not touch any electrical switch; do not use any 

phone in your building .

•  

immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions.

• 

Read this owner’s manual carefully and completely before trying to assemble, operate, or service this 

fireplace. 

• 

Any change to this fireplace or its controls can be dangerous.

• 

Improper  installation  or  use  of  this  fireplace  can  cause  serious  injury  or  death  from  fire,  burns, 

explosions, electrical shock and carbon monoxide poisoning.

W

ARNING

Содержание CLLDVNSCSB

Страница 1: ...ation service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier Thisappl...

Страница 2: ...lation 34 Wall Switch Installation 34 Signature Command Wiring Diagram 35 Optional Fan Blower Systems 36 Signature Command Single Blower BLOTSTSC 36 Automatic Dual Thermostat Blower BLOTBLDV 37 Automa...

Страница 3: ...ctions for future reference IMPORTANT SAFETY INFORMATION This fireplace is a vented product This fireplace must be properly installed by a qualified service person The glass door must be properly seat...

Страница 4: ...ect Vent type appliances draw all combustion air from outside of the dwelling through the vent pipe These appliances have been tested by CSA and found to comply with the established standards for DIRE...

Страница 5: ...ut deration for elevations up to 4 500 feet 1 370 m above sea level For elevations above 4 500 feet 1 370 m in USA installations must be in accordance with the current ANSI Z223 1 NFPA 54 and or local...

Страница 6: ...84 mm 35 903 mm 28 718 mm 25 654 mm 33 840 mm 1 32 mm 34 864 mm 11 298 mm 3 95 mm 24 610 mm 27 705 mm 46 1178 mm 38 979 mm 7 200 mm FP2852 LDV corner dims 12 305 mm 47 1216 mm 41 1064 mm 37 962 mm 23...

Страница 7: ...m 18 470 mm 28 718 mm 25 654 mm 7 200 mm 5 130 mm 1 29 mm 33 840 mm 38 979 mm 46 1178 mm 7 200 mm 12 305 mm 47 1216 mm 41 1064 mm 37 962 mm 23 584 mm Fp2853 LDV Penin dims 35 903 mm 28 718 mm 1 32 mm...

Страница 8: ...TLDV See thru Framing If using 5 8 drywall remove noncombustible supports rotate 180 and reinstall to achieve 5 8 depth The fireplace must be secured to the floor and or to framing studs as shown in F...

Страница 9: ...positioned slightly inwards If using 5 8 drywall remove framing tabs and re install on 2nd set of holes positioned slightly inwards The fireplace must be secured to the floor and or to framing studs a...

Страница 10: ...ustible Material Fold Outer Tabs and Nail to Framing Members Figure 7 PFDV Peninsula Framing If using 5 8 drywall remove framing tabs and re install on 2nd set of holes positioned slightly inwards The...

Страница 11: ...elow top of standoffs NOTE When planning your framing and installation keep in mind that the gas line and electric power come in on the same end of the fireplace Refer to Figures 2 3 4 for fireplace d...

Страница 12: ...rom appli ance Y B C Y X LU586 Locating unit D A Island C and Room Divider D installation is possible as long as the horizontal portion of the vent system X does not exceed 20 610cm See details in Ven...

Страница 13: ...stible material other than wood flooring If installed on carpet or vinyl flooring the appliance shall be installed on a metal wood or noncombustible material panel extending full width and depth of th...

Страница 14: ...instructions completely and thoroughly before attempting installation Failure to do so could result in serious injury property damage or loss of life Operation of improperly installed and maintained v...

Страница 15: ...ox and remove the pipe and gasket Figure 13 5 Replace the flue pipe to top of firebox Ensure the gasket is in place and undamaged Secure with six 6 screws Figure 14 6 Place the flue pipe cover and gas...

Страница 16: ...pipe penetrates outside wall A minimum 1 clearance to combustibles permitted all around flue at outside wall FP2819 WARNING Horizontal sections of this vent system require a minimum of 3 clearances t...

Страница 17: ...combustible material Maintain proper clearances to all combustible materials WARNING Alwaysmaintainminimumclearancesaround vent systems The minimum clearances to combustibles for horizontal vent pipe...

Страница 18: ...BTU h 30kW 36 91cm for appliances 100 000 BTU h 30kW 6 15cm for appliances 10 000 BTU h 3kW 9 23cm for appliances 10 000 BTU h 3kW and 50 000 BTU h 15kW 12 30cm for appliances 50 000 BTU h 15kW C Clea...

Страница 19: ...ions in Feet 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 2 4 6 8 10121416 1820 eg A FP2132 sidewall vent graph 323 4 to Center of Horizontal Pipe Outside Corner Inside Corner Termination C...

Страница 20: ...ructions for further instructions 3 Locate and cut the vent opening in the wall For com bustible walls first frame in opening Combustible Interior Walls Cut a 121 2 x 101 2 hole through the interior w...

Страница 21: ...on HOT FP1955 horizontal vent cap Cut Vinyl Siding Away to Fit Standoff Standoff 1250 or 5DT VS Not required for Vermont Castings Group termination Termination Bolt Wood Screw Nut Apply Mastic to all...

Страница 22: ...lbow to the face of the finished outside wall or the mounting flange of the termination The maximum number of 90 elbows per side wall installation is three 3 Figure 25 If a 90 elbow is fitted directly...

Страница 23: ...or wall frame Figure 25 Noncombustible Walls Hole opening should be 81 2 216 mm in diameter 2 The center of the hole should line up with the center line of the horizontal rigid vent pipe end Allow 1 4...

Страница 24: ...minimum 24 vertical rise is nec essary The maximum horizontal run with the 24 vertical pipe is 36 This measurement is taken from the collar of the fireplace or transition elbow to the face of the exte...

Страница 25: ...and bottom until the flue penetrates the outside wall A minimum 1 clearance all around the flue is acceptable at this point of penetration Unless the vertical run is 71 2 feet or higher form floor of...

Страница 26: ...969 offset w wallstrap Figure 37 Offset with Wall Strap and 45 Elbows Roof Flashing Wall Strap 45 Elbows Ceiling Firstop FP1669 FLAT CEILING INSTALLATION 1 Cut a 101 2 267 mm square hole in the ceilin...

Страница 27: ...o Page 26 Figure 37 Whenever possible use 45 elbows instead of 90 elbows The 45 elbow offers less restriction to the flow of the flue gases and intake air 5 Place the flashing over the pipe section s...

Страница 28: ...xible vent pipe and push out of the way 3 Pull and extend the inner flexible vent 4 Slide the inner vent onto the adapter collar for a minimum 13 4 overlap 5 Locate the clamp at approximately 3 4 from...

Страница 29: ...nation ring as in Figure 45 3 Review Figure 45 for proper overlap and clamp placement 4 Three each self penetrating screws are drilled opposite one another and below the gear lamp 5 Use only listed an...

Страница 30: ...4 x 7 Rigid Pipe Length Flex to Pipe Adapter DVFFA 8 Gear Clamp 13 4 Flexible Pipe and Adapter Outer Collar Overlap UL1777 Flex Vent Figure 48 Typical Pipe Connection Gear Clamp FP1976 horizontal flex...

Страница 31: ...alternative to test gauge connection Purchase the CSA design certified equip ment shutoff valve from your dealer For propane LP connections only the installer must supply an external regulator The ex...

Страница 32: ...UTION A manual shutoff valve must be installed upstream of the appliance Union tee and plugged 1 8 NPT pressure tapping point should be installed upstream of the appliance Figure 51 CAUTION Use pipe j...

Страница 33: ...ower supply Four 4 AA batteries are used for back up during power outages 2 The Signature Command System can also be operated without A C power The system can run on four 4 AA batteries for approximat...

Страница 34: ...ll Do not extend beyond the 15 ft wire cable provided If a longer distance is required the 15 ft may be extended up to 30 ft maximum by using two 2 SCSWEK cables plugged together Route the wire from j...

Страница 35: ...Black Optional Aux Green Plug in Connector Connector Pin To Control Board Input 300 Watt Max Each Optional A C Module Replaces 6V Adapter When Used 6V AC Adapter Control Board RF Receiver ON OFF Butto...

Страница 36: ...ctions should only be performed by a qualified licensed electrician Main power supply must be turned off before connecting the fan to the main electrical power supply or performing service BLOTSTSC SI...

Страница 37: ...gure 56 BLOTBLDV Blower Wiring Diagram FP2685 Before installing the blower wire the receptacle into an electrical circuit This should be done before framing the fireplace Wire with minimum 60 C wire i...

Страница 38: ...ifting up and out 2 Release two clamps on bottom of fireplace Figure 58 3 Tilt glass frame out and lift glass frame up until it clears three tabs on top of fireplace 4 Set glass frame aside DANGER HOT...

Страница 39: ...t place embers over the burner slots To better enable the gas to permeate the rock wool apply the rock wool in light dime size fluffy pieces WARNING Do not use the entire bag of rock wool to cover the...

Страница 40: ...toward the nearest glass The other end of the log rests on the second tine from the end closest to the pilot Figure 63 LG965 designer BV log 1 LOG PLACEMENT 1 Hold log 1 with the rounded end opposite...

Страница 41: ...lace FIREPLACE INSTALLATION LG969 Designer DV log 5 5 Place log 5 on the key provided on log 4 Rest the other end of the log on the false bottom hearth just outside of the grate It should be almost to...

Страница 42: ...ec cet appareil et doit tre install DANGER CERTIFIED SAFETY BARRIER Install the Large Screen Figure 65 1 Remove screen from packaging 2 Align the three 3 slots in the top of the screen with the three...

Страница 43: ...phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your finger to push in the master switch Never use tools If the switch will not f...

Страница 44: ...r If you smell gas STOP Follow B in the safety information on Page 43 If you do not smell gas go to next step 4 Press the master switch to the ON position Within eight 8 seconds it will beep once This...

Страница 45: ...itter X X X X X Child Proof Lock out X X X X X LCD Backlight X X X X X Security Codes 16 X X X X X Countdown 6 hr Timer X X X Standard Thermostatic Control Mode X X X Smart Mode Thermostat Auto Flame...

Страница 46: ...nds when the master switch Shutoff on the main burner is off RF Remote Receiver Push the RF receiver On Off button on the control board RF OFF On Off Beep once for ON and beep twice for OFF Learn Remo...

Страница 47: ...ame height 2 Press the OFF button to decrease flame height The first two presses will decrease the flame height to medium and low Self Diagnostics Chart The Command Center has a self diagnostic LED en...

Страница 48: ...int or foreign material with a brush or vacuum BURNER FLAME The flames from the burner should be visually checked as soon as the heater is installed and periodically during normal operation In normal...

Страница 49: ...teri als may be used Handle glass door with care to avoid striking or scratch ing it on hard objects To clean glass door follow Glass Removal procedure outlined in the Final Installation section Film...

Страница 50: ...o through Battery polarity wrong LED on the Command Center does not show solid green The 5 pin connector on the AC board broken or bent AC plug is plugged to AC mains Battery voltage low Using battery...

Страница 51: ...1 20302401 2 Access Panel 2 2 1 20302126 3 Glass Frame Assembly Short 1 1 20302151 4 Access Panel Short 1 1 20302127 5 Grate 1 1 1 20301124 6 Large Safety Barrier Assembly 2 2 1 20307088 7 Small Safe...

Страница 52: ...52 20306750 Designer Series Direct Vent Gas Fireplace REPLACEMENT PARTS SIGNATURE COMMAND SYSTEM 1 12 2 3 4 15 13 7 16 11 5 9 6 8 2381 LDV SCS burner parts...

Страница 53: ...18 w Shutoff Valve 1 69D0030 69D0030 12 Pilot SCS 1 80D0006 13 Grommet 1 73D0189 73D0189 14 Sealant 1 28D0149 28D0149 15 Control Board SCS 1 80D0018 80D0019 16 Command Center SCS 1 80D0005 80D0005 17...

Страница 54: ...302434 4 Log 4 1 20302435 5 Log 5 1 20302436 LOGS 2381 Designer LDV logs 5 1 2 3 4 BRICK 2381 LDV brick parts 1 2 3 4 Herringbone Brick Traditional Brick Ref Description Cottage Red Olde English Vinta...

Страница 55: ...20306750 55 Designer Series Direct Vent Gas Fireplace REPLACEMENT PARTS VENT COMPONENTS HOT 1 2 3 4 5 6 9 7 8 11 10 0004 MLDV vent parts...

Страница 56: ...DT 09 3 6 12 Pipe Length galvanized 46DVA 12 906 4DT 1 3 6 24 Pipe Length galvanized 46DVA 24 904 4DT 4 3 6 36 Pipe Length galvanized 46DVA 36 903 4DT 36 3 6 48 Pipe Length galvanized 46DVA 48 902 4DT...

Страница 57: ...24 1204 5DT 24 5D24 3 4 36 Pipe Length 58DVA 36 1203 5DT 36 5D36 3 4 48 Pipe Length 58DVA 48 1202 5DT 48 5D48 4 4 81 2 Pipe Extension 58DVA 08A 5DT AJ 4 4 16 Pipe Extension 58DVA 16A 5 4 45 Elbow 58DV...

Страница 58: ...7TDVP1218 35 64 Adjustable Vent Length 7TDVP3564 8 Vent Pipe 4 pack 7TDVP8 4 12 Vent Pipe 4 pack 7TDVP12 4 24 Vent Pipe 4 pack 7TDVP24 4 36 Vent Pipe 7TDVP36 36 Vent Pipe 30 pack 7TDVP36 30 48 Vent Pi...

Страница 59: ...0 pack 7TDVP36 30 48 Vent Pipe 7TDVP48 48 Vent Pipe 30 pack 7TDVP48 30 5 x 8 to 4 x 7 Adapter 7TDVP58 Flex Adapter Starter Kit DVFFA 8 Twist Lock Elbows 45 Elbow for Vertical Horizontal Offset 7TDV45...

Страница 60: ...thirty 30 days to comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed MASSACHUSETTS...

Страница 61: ...Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly...

Страница 62: ...62 20306750 Designer Series Direct Vent Gas Fireplace This page left blank...

Страница 63: ...20306750 63 Designer Series Direct Vent Gas Fireplace This page left blank...

Страница 64: ...que de rendement nerg tique de foyer au gaz nerguide Selon CSA P 4 1 09 149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgroup com EFFICIENCY RATINGS MODEL ENERGUIDE RATINGS FIREPLACE EFFIC...

Отзывы: