The pilot will resist lighting on new installations 
due to air in the  gas supply line.  It may take sev-
eral minutes to bleed air completely out of the gas 
plumbing system through the pilot line.

This appliance has a pilot which is lit by a spark igni-
tion device (piezo).  If the piezo fails, then light the pilot 
using matches following the 

Match Lighting

 instruc-

tions below.

 

1)  STOP! Read the safety information above.
2)  Push in gas control knob slightly and turn clockwise 

 to “OFF”.

3) 

NOTE: Knob cannot be turned from “PILOT” to 
“OFF” unless knob is pushed in slightly. Do not 
force.

4)  Wait five (5) minutes to clear out any gas.  If you 

then smell gas, 

STOP

!  Follow the safety information 

above.  If you don’t smell gas, go on to the next step.

5)  Turn the control knob counterclockwise 

 to “PI-

LOT” and push in. Continue to hold the

 

control knob 

in and push the piezo igniter button in until the pilot 
lights. 

6)  Continue to hold the control knob in for about one (1) 

minute after the pilot is lit. Release the knob and it 
will pop back up. Pilot should remain lit. If it goes out, 
repeat steps 3 and 4.

7)  If the knob does not pop out when released, stop and 

call your service technician or gas supplier. If the pilot 
will not stay lit after several tries, turn the gas control 
knob to “OFF’ and call your service technician or gas 
supplier.

8)  Turn gas control knob counterclockwise 

 to 

“ON”. CAUTION: Be sure ON/OFF/RS switch is in the 
off (middle) position. Also, the GWSK should be in 
the “OFF” position and/or the remote should be in the 
“OFF” position before turning the control knob “ON”. 
If pilot goes out, repeat steps 4 and 5.

9)  Turn ON/OFF/RS switch to “ON” or remote position. 

Turn remote switch to “ON”.

10) Flame is adjustable by rotating the “HI/LO” knob.

Lighting the Pilot

Before operating, smell all around the appliance area for gas odor.  Be sure to smell near the floor because 
some gases (propane) are heavier than air and will “pool” on the floor. 

Use only your hand to push or turn the gas control dial.  

NEVER USE TOOLS. 

 If the knob will not push in 

or turn by hand, don’t try to repair it, call a qualified technician.  Force or attempted repair may result in a 
fire or explosion.

WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance
•  Do not touch any electrical switch, do not use any phone in your building
•  Immediately call your gas supplier from a neighbor’s phone.  Follow the 
 

gas supplier’s instructions

•  If  you cannot reach your gas supplier, call the fire department

For Your Safety Read Before Lighting

WARNING: If you do not follow these directions exactly, a fire or explosion may result 
causing property damage, personal injury, or loss of life.

Leak Test Procedures

Create a mixture of equal parts soap and water.  Apply to all the joints of the pipe fittings from the gas supply 
pipe to the burner.  Turn on the gas supply valve for no longer than 3-5 seconds.  If bubbles appear in the soap 
solution applied to the joints, there is a leak.  Turn off the gas supply valve and tighten those fittings.  Repeat the 
above procedure until no bubbles appear in the soap solution.  Remember to test all joints.

WARNING: DO NOT USE AN OPEN FLAME TO TEST FOR LEAKS!
NOTE: Always perform a leak test any time the appliance has been moved or disconnected from the 
gas supply line.

Содержание A18CFLRN

Страница 1: ...T CAUSING PROPERTY DAMAGE INJURY OR LOSS OF LIFE ATTENTION INSTALLATION AND SERVICE MUST BE PER FORMED BY A QUALIFIED AGENCY INDI VIDUAL FIRM CORPORATION OR COMPANY EXPERIENCED IN THE INSTALLATION REP...

Страница 2: ...fuel or fuel combustion which are known to the state of California to cause can cer birth defects or other reproductive harm Do not use this appliance or any part that has been under water Immediately...

Страница 3: ...place supply tanks inside any structure G Never use sand or other dense pan material with propane gas use vermiculite only H Be sure to apply pipe joint compound to all non ared threaded connections...

Страница 4: ...uali ed installer must install one Have you checked local building codes Check with your local Building Dept Does you replace have a wire mesh screen in place Propane Gas Units Minimum Clearances Spec...

Страница 5: ...a template to drill two 2 1 8 holes in the Damper Locking Bracket to mount the Damper Stop NOTE Your gas log set is assembled at the factory to be installed in a replace plumbed with the gas on the ri...

Страница 6: ...the vent is prop erly drawing it up the chimney If the smoke is drawn back into the room extinguish the ame and remove any obstruction until proper venting is achieved If that fails check with a quali...

Страница 7: ...bers and place them on top of the Silica Sand evenly across the Burner Pan Be sure to separate the Glowing Embers into very small pieces before placing them onto the Silica Sand Remote Installation Co...

Страница 8: ...mes should come up directly between these two logs 4 Next place the smaller top logs diagonally onto the bottom logs The top logs can be arranged to achieve your desired ame pattern Refer to Figures 1...

Страница 9: ...FF position before turning the control knob ON If pilot goes out repeat steps 4 and 5 9 Turn ON OFF RS switch to ON or remote position Turn remote switch to ON 10 Flame is adjustable by rotating the H...

Страница 10: ...re coming into the replace does not ex ceed the maximum pressure allowed with this gas set refer to tables on Page 4 Match Lighting Burner is Excessively Noisy Please note The movement and combustion...

Страница 11: ...the Piezo wire is not loose call our customer service line Incorrect Pilot Ori ce Make sure the correct Pilot Ori ce is installed green for Natural Gas red for propane Incorrect gas supply pressure Ma...

Страница 12: ...any time without notice A18 24 30CFL DragonFire with Remote Pilot Ref Description A18CFLR A24CFLR A30CFLR 1 Complete Log Set 20004307 20004308 20004309 1a Outside Left Cross Log NNS2 n a n a 20004600...

Страница 13: ...304045 4304045 16 Flexible Gas Connector 3304176 3304176 3304176 17 Ori ce Wrench LP units 3309025 3309025 3309025 18a Pan and Extension Assembly 20003840 20003841 20003842 18b Burner Tube 3 8 2000382...

Страница 14: ...14 20003903...

Страница 15: ...anties speci ed in paragraphs A and B below with respect to its Vermont Castings Decorative Gas Appliances the Gas Ap pliance including CFM Specialty Home Products supplied accessories and components...

Страница 16: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com CFM Specialty Home Products...

Отзывы: