4
20003903
CAUTION: If you answered “NO” to any item, or have any questions regarding your installation,
please contact your dealer/distributor for assistance.
Pre-Installation Check List
YES NO
Is the gas supply inlet pressure correct?
NG: Min. 5.0” w.c./ Max. 10.5” w.c.
LP: Min. 11.0” w.c.;Max. 14.0” w.c.
Does the firebox meet the minimum size dimensions below?
Is your fireplace plumbed with gas on the right side (facing) of the fireplace? If not, see
page 10.
Is the gas supply line sized properly (Minimum 1/2” Iron Pipe)?
Do you have a solid fuel (wood burning) fireplace with a vented flue?
Do you have a manual gas supply valve installed at your fireplace? If not, a licensed
plumber, gas company technician or other qualified installer must install one.
Have you checked local building codes? (Check with your local Building Dept.)
Does you fireplace have a wire mesh screen in place?
Propane Gas Units -- Minimum Clearances & Specifications
Set
Input
Width
Flue
Pressure
Manifold
Size
Btu/hr
Back Front Depth Height
Size
Minimum Maximum
Pressure
18”
40,000
19” 27”
15”
18”
51 sq.in.
11” w.c. 14” w.c.
11” w.c.
24”
45,000
23” 33”
15”
18”
51 sq.in.
11” w.c. 14” w.c.
11” w.c.
30”
60,000
30” 39”
18”
18”
79 sq.in.
11” w.c. 14” w.c.
11” w.c.
Min. Firebox Dimensions
Minimum
Gas Fuel Line
Natural Gas Units -- Minimum Clearances & Specifications
Set
Input
Width
Flue
Pressure
Manifold
Size
Btu/hr
Back Front Depth Height
Size
Minimum Maximum
Pressure
18”
54,000
19” 27”
15”
18”
51 sq.in.
5” w.c.
10.5” w.c.
3.5” w.c.
24”
75,000
23” 33”
15”
18”
51 sq.in.
7” w.c.
10.5” w.c.
3.5” w.c.
30”
75,000
30” 39”
18”
18”
79 sq.in.
7” w.c.
10.5” w.c.
3.5” w.c.
Min. Firebox Dimensions