background image

3

20003903

Before You Begin -- ATTENTION!

 

A.

  The appliance should be inspected before use and at least annually by a professional    

 

 

service person.  More frequent cleaning may be required due to excessive lint from    

 

 

carpeting, bedding material, etc.  It is imperative that control  compartments, burners and  

 

 

 

circulating air passageways of the appliance be kept clean. 

 
 

B.

  Your fireplace must include a chain mesh or similar screen.  The screen must remain  

 

 

 

fully closed while operating your log set.  Any safety screen or guard removed for 

 

 

servicing this appliance must be replaced prior to operation.   

 

 

C.

  If your fireplace includes glass doors, they must remain 

fully open

 to allow for combustion  

 

 

air during operation, and to prevent overheating of the gas valve.

 

D.

  Your log set must be installed in a solid fuel burning fireplace constructed of 

 

 

noncombustible material with a working flue.

 

E.

  Solid fuels shall not be burned in the fireplace where your gas log set is installed.

 

F.

  If this log set is to be used with propane gas, your propane supply tank MUST include a 

 

 

high to low gas pressure regulator, and must be located outside.  DO NOT place supply   

 

 

tanks inside any structure .

 

G.

  Never use sand or other dense pan material with propane gas: use vermiculite only.  

 

H.

  Be sure to apply pipe joint compound to all non-flared, threaded connections involved in this  

 

 

installation to avoid possible gas leaks.  Compounds used in liquid propane 

 

 

applications must be resistant to the action of that gas.

 

I.

  Always test for leaks using a soapy solution.  NEVER USE OPEN FLAME.

 

J.

  The manufacture and shipping of your log set involves compounds which may cause  

 

 

 

detectable yet harmless odors during initial operation.  Provide extra ventilation to the  

 

 

 

room for the initial 2-3 hour break-in period.

 

K.

  This gas log set may be installed in the approved fireplace in an aftermarket* manufactured  

 

 

(mobile) home where not prohibited by state or local codes. 

 

 

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.

     L.

  The fireplace damper

 MUST 

be fully open when operating this log set.

Fireplace Specifications

 

Before installation, the chimney flue, venting system, and firebox must be cleaned of all soot,    

creosote, ashes and loose paint, by a qualified chimney cleaner.

Your Fireplace Must Include:

•   A working flue and venting system with the minimum openings indicated on Page

 

.

•   A gas supply shut off valve.  If your fireplace does not have such a valve,  one must be installed.

Содержание A18CFLRN

Страница 1: ...T CAUSING PROPERTY DAMAGE INJURY OR LOSS OF LIFE ATTENTION INSTALLATION AND SERVICE MUST BE PER FORMED BY A QUALIFIED AGENCY INDI VIDUAL FIRM CORPORATION OR COMPANY EXPERIENCED IN THE INSTALLATION REP...

Страница 2: ...fuel or fuel combustion which are known to the state of California to cause can cer birth defects or other reproductive harm Do not use this appliance or any part that has been under water Immediately...

Страница 3: ...place supply tanks inside any structure G Never use sand or other dense pan material with propane gas use vermiculite only H Be sure to apply pipe joint compound to all non ared threaded connections...

Страница 4: ...uali ed installer must install one Have you checked local building codes Check with your local Building Dept Does you replace have a wire mesh screen in place Propane Gas Units Minimum Clearances Spec...

Страница 5: ...a template to drill two 2 1 8 holes in the Damper Locking Bracket to mount the Damper Stop NOTE Your gas log set is assembled at the factory to be installed in a replace plumbed with the gas on the ri...

Страница 6: ...the vent is prop erly drawing it up the chimney If the smoke is drawn back into the room extinguish the ame and remove any obstruction until proper venting is achieved If that fails check with a quali...

Страница 7: ...bers and place them on top of the Silica Sand evenly across the Burner Pan Be sure to separate the Glowing Embers into very small pieces before placing them onto the Silica Sand Remote Installation Co...

Страница 8: ...mes should come up directly between these two logs 4 Next place the smaller top logs diagonally onto the bottom logs The top logs can be arranged to achieve your desired ame pattern Refer to Figures 1...

Страница 9: ...FF position before turning the control knob ON If pilot goes out repeat steps 4 and 5 9 Turn ON OFF RS switch to ON or remote position Turn remote switch to ON 10 Flame is adjustable by rotating the H...

Страница 10: ...re coming into the replace does not ex ceed the maximum pressure allowed with this gas set refer to tables on Page 4 Match Lighting Burner is Excessively Noisy Please note The movement and combustion...

Страница 11: ...the Piezo wire is not loose call our customer service line Incorrect Pilot Ori ce Make sure the correct Pilot Ori ce is installed green for Natural Gas red for propane Incorrect gas supply pressure Ma...

Страница 12: ...any time without notice A18 24 30CFL DragonFire with Remote Pilot Ref Description A18CFLR A24CFLR A30CFLR 1 Complete Log Set 20004307 20004308 20004309 1a Outside Left Cross Log NNS2 n a n a 20004600...

Страница 13: ...304045 4304045 16 Flexible Gas Connector 3304176 3304176 3304176 17 Ori ce Wrench LP units 3309025 3309025 3309025 18a Pan and Extension Assembly 20003840 20003841 20003842 18b Burner Tube 3 8 2000382...

Страница 14: ...14 20003903...

Страница 15: ...anties speci ed in paragraphs A and B below with respect to its Vermont Castings Decorative Gas Appliances the Gas Ap pliance including CFM Specialty Home Products supplied accessories and components...

Страница 16: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com CFM Specialty Home Products...