background image

11

20003903

Troubleshooting

Pilot Will Not Light

Upon initial installation, the pilot may be difficult to light, due to air in the gas line, valve, and pilot tub-

ing.  If the pilot does not light for several minutes, try using a match to ignite it for the first few times.  
Initialing lighting the pilot may take up to five minutes of bleeding the line.

Piezo Igniter Out of Position:  

First make sure that, when the igniter button is pushed in, the igniter 

electrode at the Pilot Assembly is sparking.  If it is, make sure the Igniter Electrode’s tip sits directly over 
the pilot’s hood.  If it doesn’t, adjust it carefully into position.

Piezo Igniter Not Sparking: 

 If the electrode is not sparking, first make sure the wire which connects 

the electrode to the Piezo Push Button is not loose on either side.  If the Piezo wire is not loose, call our 
customer service line.

Incorrect Pilot Orifice:

  Make sure the correct Pilot Orifice is installed: green for Natural Gas, red for 

propane.

Incorrect gas supply pressure:  

Make sure your gas pressure meets the specifications outlined on 

Page 4.

Flames at the Air Mixer (Flashback)--Propane Gas Only

Correct Orifice used

: Be sure you only used the Orifices that came with this pilot kit.  

Do not use the 

Orifice that came with your gas log set!

Incorrect gas supply pressure:  

Make sure your gas line meets the specifications outlined on Page 4.

  

Burner Flame is too High (8-12” Above Top Logs) or too Low:

Incorrect gas supply, pressure, or burner orifice used:

 Make sure the gas pressure coming into the 

fireplace falls between the minimum and maximum pressures allowed with this gas set (refer to tables 
on Page 4).  Make sure you installed the correct orifice into the set.

Blocked ports (low flame only):

 Free the main burner orifice and burner bar ports of any burrs, paint, 

or other blockage.

Содержание A18CFLRN

Страница 1: ...T CAUSING PROPERTY DAMAGE INJURY OR LOSS OF LIFE ATTENTION INSTALLATION AND SERVICE MUST BE PER FORMED BY A QUALIFIED AGENCY INDI VIDUAL FIRM CORPORATION OR COMPANY EXPERIENCED IN THE INSTALLATION REP...

Страница 2: ...fuel or fuel combustion which are known to the state of California to cause can cer birth defects or other reproductive harm Do not use this appliance or any part that has been under water Immediately...

Страница 3: ...place supply tanks inside any structure G Never use sand or other dense pan material with propane gas use vermiculite only H Be sure to apply pipe joint compound to all non ared threaded connections...

Страница 4: ...uali ed installer must install one Have you checked local building codes Check with your local Building Dept Does you replace have a wire mesh screen in place Propane Gas Units Minimum Clearances Spec...

Страница 5: ...a template to drill two 2 1 8 holes in the Damper Locking Bracket to mount the Damper Stop NOTE Your gas log set is assembled at the factory to be installed in a replace plumbed with the gas on the ri...

Страница 6: ...the vent is prop erly drawing it up the chimney If the smoke is drawn back into the room extinguish the ame and remove any obstruction until proper venting is achieved If that fails check with a quali...

Страница 7: ...bers and place them on top of the Silica Sand evenly across the Burner Pan Be sure to separate the Glowing Embers into very small pieces before placing them onto the Silica Sand Remote Installation Co...

Страница 8: ...mes should come up directly between these two logs 4 Next place the smaller top logs diagonally onto the bottom logs The top logs can be arranged to achieve your desired ame pattern Refer to Figures 1...

Страница 9: ...FF position before turning the control knob ON If pilot goes out repeat steps 4 and 5 9 Turn ON OFF RS switch to ON or remote position Turn remote switch to ON 10 Flame is adjustable by rotating the H...

Страница 10: ...re coming into the replace does not ex ceed the maximum pressure allowed with this gas set refer to tables on Page 4 Match Lighting Burner is Excessively Noisy Please note The movement and combustion...

Страница 11: ...the Piezo wire is not loose call our customer service line Incorrect Pilot Ori ce Make sure the correct Pilot Ori ce is installed green for Natural Gas red for propane Incorrect gas supply pressure Ma...

Страница 12: ...any time without notice A18 24 30CFL DragonFire with Remote Pilot Ref Description A18CFLR A24CFLR A30CFLR 1 Complete Log Set 20004307 20004308 20004309 1a Outside Left Cross Log NNS2 n a n a 20004600...

Страница 13: ...304045 4304045 16 Flexible Gas Connector 3304176 3304176 3304176 17 Ori ce Wrench LP units 3309025 3309025 3309025 18a Pan and Extension Assembly 20003840 20003841 20003842 18b Burner Tube 3 8 2000382...

Страница 14: ...14 20003903...

Страница 15: ...anties speci ed in paragraphs A and B below with respect to its Vermont Castings Decorative Gas Appliances the Gas Ap pliance including CFM Specialty Home Products supplied accessories and components...

Страница 16: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com CFM Specialty Home Products...

Отзывы: