OWNER’S MANUAL
52
VERLINDE reserves the right to alter or amend the above information without notice
11/2018
Adjusting limitation (current) using the frequency drive:
1/ Winch switched on displays
0000
, press save button
2/ Press browse button
several times until
C001
is displayed
3/ Press up button
until
C041
is displayed
4/ Press save button
5/ A value in amperes is displayed: increase to the maximum using the up button
, then press
save
6/ Press the browse button
until
D001
is displayed
7/ Press the up button
until
D002
is displayed (current reading in ampere)
8/ Press save button
0000
is displayed (Load winch at the required stop value)
9/ Activate lifting (direct ampere reading). For example, 5 A at XX kg stop required.
10/ Return to
C041
using the save button
then browse
, save
and press up
. Adjust to 5A (for example) using the up
or down
button and save
.
11/ Press browse
D001
then save
and use.
To reset to the default setting E12 press the stop reset button
or the ignition key on the AE