OWNER’S MANUAL
50
VERLINDE reserves the right to alter or amend the above information without notice
11/2018
Grooved drum
Facilitates correct winding of the rope on the first layer. Essential
when installing a two-way system.
Electronic load limiter
With CROUZET limiter
The winch is adjusted in the factory with the electrical voltage indicated on the test report
enclosed with this instruction manual. If this voltage is different in the place of use, the
setting must be readjusted.
In the event of overloading of the winch, a load limitation by motor current measurement cuts the lift
control.
Once you have identified and eliminated the cause of the load limiter activation, use the key-activated
turning button on the right of the unit to reset the load limiter and use the winch again.
Adjust the sensitivity of the load limiter by adjusting the "
I value
" on the limiter using a small flat
screwdriver:
the load limiter is adjusted in the factory to the value of about 110% of its MCU.
IMPORTANT!
Setting the threshold too high may lead to major risks both for the equipment and the
operators.
I value