9
Separate the inner rail from the other rail components in the rack.
10
Attach the inner rail to the left and the right sides of the chassis at the four
attachment locations.
The rails click into place when properly installed.
Installing the compute node into a rack
After the storage shelves and the compute node rails have been installed, you can
install the compute node into the rack.
To install the compute node into the rack
1
Verify that the rails are securely attached.
■
Verify that the outer rail is securely attached to the rack.
■
Pull the intermediate rail forward. Ensure that the ball bearing retainer is
locked forward.
■
Verify that the inner rail is securely attached to the compute node.
2
Place the hardware in the front of the rack.
46
Hardware installation procedures
Installing the compute node into a rack