Pub. # OM20-MSP3-3D
4-26
Mapping with SoilViewer
Attach the pH serial communication cable to an available COM port on your computer. Connect EC
signal cable and power cords to ports on rear of VSense Controller, connect the GPS to the GPS
in of the OM Comm. cable, then connect the serial output of the OM Comm. to any available COM
port on your computer using a standard serial cable. If serial port is not available on PC, then a
USB to Serial converter can be used with the VSense Controller provided the drivers for the
converter are installed and functioning properly.
SoilViewer startup display
Figure 52
Figure 53
To acquire EC, OM and
pH data select Acquisition
Select either 3150 (2
depth EC Systems) or
3210 (3 Depth EC
Systems)