background image

www.venuelightingeffects.com

7

Mounting orientation
The lightweight ThinPar 64 may be mounted in any position.
 
rigging
Be sure that the structure can support the weight of the fixture. Please see the “Technical Specifications” section of this 
manual for a detailed weight listing. Mount the fixture securely. This may be done with a screw, nut and bolt, or a hanging 
clamp (not included). The hole in each bracket can fit a 13mm screw or bolt. When rigging, consider routine maintenance 
and back panel access. Please see the following steps for installation.

 

• 

If the power link out is intended to be used with multiple fixtures, take into account the length of each power 

 

 

cable, and mount the fixtures close enough to one another to account for this.

 

• 

When aiming the fixtures, you may use the bracket angle knob. Loosen the knob, adjust to the desired angle,  

 

and then tighten the knob by turning clockwise. Do not use tools for this step, as it may cause damage.

 

• 

There is a secondary bracket, which may be used primarily for floor standing positions.

 

• 

Safety cables must always be used.

BRACKET ANGLE KNOB

Note: Do not use a tool on 

the bracket angle knob. 

Tighten or loosen by hand.

MOUNTING BRACKET

SECONDARY BRACKET

(use primarily for floor standing position)

Содержание Thinpar 38

Страница 1: ...thinpar 64 OWNER S MANUAL www venuelightingeffects com...

Страница 2: ...DMX OPERATION 11 Configuring the starting address 11 Master slave standalone operating modes 11 7 Ch mode DMX operation 12 3 Ch mode DMX operation 12 8 Appendix 13 DMX primer 13 General troubleshootin...

Страница 3: ...xt CONVENTION MEANING Menu Key to be pressed on the fixture s Control Display 1 512 Range of values 50 60 Set of values of which only one can be chosen Settings Menu option not to be modified for exam...

Страница 4: ...ed in a location with adequate ventilation at least 20 50 cm from adjacent surfaces Be sure that no ventilation slots are blocked Always disconnect from the power source before servicing or replacing...

Страница 5: ...sound activated programs via master slave or DMX Pulse effect with adjustable speed 3 or 7 channel DMX 512 operation Additional Features 2 5 low profile design Power linking 40 units 120V 60 units 230...

Страница 6: ...g indicates its average current draw under normal conditions Always connect the fixture to a switched circuit Never connect the fixture to a rheostat variable resistor or dimmer circuit even if the rh...

Страница 7: ...lowing steps for installation If the power link out is intended to be used with multiple fixtures take into account the length of each power cable and mount the fixtures close enough to one another to...

Страница 8: ...CTIONS Control Panel BUTTONS Access these functions using the four buttons located directly underneath the LED Control Display BUTTON FUNCTION MENU Scrolls through the current operating mode as well a...

Страница 9: ...ound Active Use the Audio Sensi tivity Adjustment knob located on the back of the fixture Select between 2 sound active programs P6 3 Color Sound Active DMX CONTROL 3 CH d 1 d512 Select 3 channel DMX...

Страница 10: ...static color presets These are accessed via the Control Display page 5 1 Press MENU until C appears on the LED screen 2 Press ENTER 3 Using UP and DOWN select the desired color preset C1 C7 4 Press E...

Страница 11: ...the starting address selected for future reference The Thinpar 64 uses seven or three DMX channels If this is your first time using DMX we recommend reading the DMX Primer section in the Appendix Mast...

Страница 12: ...6 000 031 032 063 064 095 096 127 128 159 160 191 192 223 224 255 Mode RGB mode Pulse effect 0 100 using RGB faders Pulse effect 100 0 using RGB faders Pulse effect 100 0 100 using RGB faders Auto fad...

Страница 13: ...ot important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted...

Страница 14: ...a link distance 500 m 1640 ft Maximum recommended number of fixtures on a serial data link 32 DMX Data Cable Use a cable which meets the specifications for EIA RS 485 applications Standard microphone...

Страница 15: ...requency As a general rule fixtures should be cleaned at least twice a month Dust reduces performance and can cause overheating This can lead to reduced lamp life and increased mechanical wear Be sure...

Страница 16: ...rmal use and service for one 1 year ninety 90 days on lamps to the original owner from the date of purchase Retailer and manufacturer shall not be liable for damages based upon inconvenience loss of u...