background image

thinpar 64 users Manual

16

9. TECHNICAL SPECIFICATIONS

Weight & dimensions
Length ................................................................................................................................ 9.7” (246mm)
Width ................................................................................................................................11.1” (282mm)
Height ...................................................................................................................................2.5” (63mm)
Weight.............................................................................................................................. 2.8 lbs (1.3 kg)

power
Auto-ranging power supply ................................................................................10.0.~240. VAC, 50./60. Hz
Power Consumption @ 120 V ...........................................................................18 W max, 0..25 A inrush
Power Consumption @ 230 V ...........................................................................16 W max, 0..14 A inrush
Power output ........................................................... 40 units @ 120V, 60 units @ 230V, 10A circuit max
Fuse ..................................................................................................................................... F 1 A, 250. V

light Source
LEDs .......................................................................................................180. (60. red, 60. green, 60. blue)

photo optic
Lux @ 1 m ...................................................................................................................................... 3,640.
Beam angle ........................................................................................................................................23°
Field angle ..........................................................................................................................................38°

thermal
Maximum ambient temperature ........................................................................................104° F (40° C)

10. WARRANTY

One (1) Year Limited Warranty
Subject to the limitations set forth below, Venue

®

 hereby represents and warrants that the components of this product 

shall be free from defects in workmanship and materials, including implied warranties of merchantability or fitness for a 
particular purpose, subject to normal use and service, for one (1) year (ninety (90) days on lamps) to the original owner 
from the date of purchase.

Retailer and manufacturer shall not be liable for damages based upon inconvenience, loss of use of product, loss of 
time, interrupted operation or commercial loss or any other incidental or consequential damages including but not limited 
to lost profits, downtime, goodwill, damage to or replacement of equipment and property, and any costs of recovering, 
reprogramming, or reproducing any program or data stored in equipment that is used with Venue

®

 products. This guar-

antee gives you specific legal rights. You may have other legal rights which vary from state to state. Some states
do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

Venue Lighting Effects
P.O. Box 5111, Thousand Oaks, CA 91359-5111
www.venuelightingeffects.com

All trademarks and registered trademarks mentioned herein are recognized as the property of their respective holders.

Made in China. 110.6-9592

Содержание Thinpar 38

Страница 1: ...thinpar 64 OWNER S MANUAL www venuelightingeffects com...

Страница 2: ...DMX OPERATION 11 Configuring the starting address 11 Master slave standalone operating modes 11 7 Ch mode DMX operation 12 3 Ch mode DMX operation 12 8 Appendix 13 DMX primer 13 General troubleshootin...

Страница 3: ...xt CONVENTION MEANING Menu Key to be pressed on the fixture s Control Display 1 512 Range of values 50 60 Set of values of which only one can be chosen Settings Menu option not to be modified for exam...

Страница 4: ...ed in a location with adequate ventilation at least 20 50 cm from adjacent surfaces Be sure that no ventilation slots are blocked Always disconnect from the power source before servicing or replacing...

Страница 5: ...sound activated programs via master slave or DMX Pulse effect with adjustable speed 3 or 7 channel DMX 512 operation Additional Features 2 5 low profile design Power linking 40 units 120V 60 units 230...

Страница 6: ...g indicates its average current draw under normal conditions Always connect the fixture to a switched circuit Never connect the fixture to a rheostat variable resistor or dimmer circuit even if the rh...

Страница 7: ...lowing steps for installation If the power link out is intended to be used with multiple fixtures take into account the length of each power cable and mount the fixtures close enough to one another to...

Страница 8: ...CTIONS Control Panel BUTTONS Access these functions using the four buttons located directly underneath the LED Control Display BUTTON FUNCTION MENU Scrolls through the current operating mode as well a...

Страница 9: ...ound Active Use the Audio Sensi tivity Adjustment knob located on the back of the fixture Select between 2 sound active programs P6 3 Color Sound Active DMX CONTROL 3 CH d 1 d512 Select 3 channel DMX...

Страница 10: ...static color presets These are accessed via the Control Display page 5 1 Press MENU until C appears on the LED screen 2 Press ENTER 3 Using UP and DOWN select the desired color preset C1 C7 4 Press E...

Страница 11: ...the starting address selected for future reference The Thinpar 64 uses seven or three DMX channels If this is your first time using DMX we recommend reading the DMX Primer section in the Appendix Mast...

Страница 12: ...6 000 031 032 063 064 095 096 127 128 159 160 191 192 223 224 255 Mode RGB mode Pulse effect 0 100 using RGB faders Pulse effect 100 0 using RGB faders Pulse effect 100 0 100 using RGB faders Auto fad...

Страница 13: ...ot important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted...

Страница 14: ...a link distance 500 m 1640 ft Maximum recommended number of fixtures on a serial data link 32 DMX Data Cable Use a cable which meets the specifications for EIA RS 485 applications Standard microphone...

Страница 15: ...requency As a general rule fixtures should be cleaned at least twice a month Dust reduces performance and can cause overheating This can lead to reduced lamp life and increased mechanical wear Be sure...

Страница 16: ...rmal use and service for one 1 year ninety 90 days on lamps to the original owner from the date of purchase Retailer and manufacturer shall not be liable for damages based upon inconvenience loss of u...

Отзывы: