Parameter
VS10-75 CG
OPTIMA
VS 40-150 CG
OPTIMA SUP
VS 40-150 CG
OPTIMA SUP-EXH
Weight
6,5
7,0
7,5
Dimensions W x H x D
240x300x130
240x400x130
240x400x130
Electrical supply system
TN
Rated power supply voltage
~230V
3~400V
3~400V
Rated current In
31A
28A
49A
Rated insulation voltage Ui
400V
Rated impulse withstand voltage Uimp
2.5kV
Rated short-time withstand current Icw for
respective circuits – effective value of alternating
current component withstood during 1 second, i.e.
short-circuit current expected at rated connecting
voltage
6kA
Rated peak withstand current (ipk) at cos
φ
= 0.5
10.2kA
Rated short-circuit current
6kA
Coincidence factor
0.9
Rated frequency
50Hz ±1Hz
Protection class
IP20
Acceptable operating temperature
0..40°C
Supply voltage of control circuits
24VAC
EMC environment
1
PARAMETERS OF PROTECTION UNITS
F1
6,3A / 250V 5x20 glass fuse
F2
6,3A / 250V 5x20 glass fuse
F3
16,0A / 250V 5x20 ceramic fuse
F4
16,0A / 250V 5x20 ceramic fuse
INPUT / OUTPUT HARDWARE CHARACTERISTICS
Digital inputs D1..D4
Nominal input voltage
High state detected within range
24VAC / 24 DC
15..27VAC / 16..38VDC
Temperature measurement inputs P1..P3
Sensor type
Min. load resistance
Refresh time
Range
Accuracy
Resolution
Pt1000
0
Ω
60ms
-76..105°C
±0.5°C
8bits / °C
Analog outputs A1, A2
Rated voltage
Max. load
Min. load resistance
Resolution
0..10V
20mA
500
Ω
7bits / V