The

Guarantee

Applicable only to products installed and used in the United Kingdom. For details of guarantee outside the

United Kingdom contact your local supplier.

Vent-Axia guarantees its products for two years from date of purchase against faulty material or workmanship.

In the event of any part being found to be defective, the product will be repaired, or at the Company

s option

replaced, without charge, provided that the product:-

Has been installed and used in accordance with the instructions given with each unit.

Has not been connected to an unsuitable electricity supply. (The correct electricity supply voltage is

shown on the product rating label attached to the unit).

Has not been subjected to misuse, neglect or damage.

Has not been modi

ed or repaired by any person not authorised by the company.

IF CLAIMING UNDER TERMS OF GUARANTEE

Please return the complete product, carriage paid to your original supplier or nearest Vent-Axia Centre, by post

or personal visit. Please ensure that it is adequately packed and accompanied by a letter clearly marked

Guarantee Claim

stating the nature of the fault and providing evidence of date and source of purchase.

The guarantee is offered to you as an extra bene

t, and does not effect your legal rights

Head Of

ce: Fleming Way, Crawley, West Sussex, RH10 9YX. Tel: 01293 526062 Fax: 01293 551188

UK NATIONAL CALL CENTRE

, Newton Road, Crawley, West Sussex, RH10 9JA

SALES ENQUIRIES:

TECHNICAL SUPPORT:

Web:-www.vent-axia.com

Tel: 0844 8560590 Fax: 01293 565169

Tel: 0844 8560594 Fax: 01293 539209

Email:-

[email protected]

As part of the policy of continuous product improvement Vent-Axia reserves the right to alter speci

cations without notice.

443463A

1109

Installation and Wiring Instructions

Speed controller

Enclosure

L-BAL-E097-GB 1002 Index 001

Part.-No. 00163342-GB

18/18

Содержание 103 14 120

Страница 1: ...Speed controller For variable voltage 1 fans Installation and Wiring Instructions Software version D1349A from Version 1 00 L BAL E097 GB 1002 Index 001 Part No 00163342 GB english...

Страница 2: ...6 4 4 Installation location for agriculture 7 4 5 Temperature in uences during commissioning 7 5 Electrical installation 7 5 1 Safety precautions 7 5 2 EMC compatible installation 7 5 2 1 Motor feede...

Страница 3: ...signal and speed 14 9 3 Operation with two variable output voltages two steps 14 10 Diagnostics Faults 15 10 1 If controller doesn t work correctly 15 11 Enclosure 16 11 1 Technical data 16 11 2 Conn...

Страница 4: ...ept no liability for damage caused by misuse incorrect use improper use or as a consequence of unauthorized repairs or modi cations 1 4 Copyright These operating instructions contain copyright protect...

Страница 5: ...n of accidents and the corresponding national as well as regional and in house regulations Personnel to be trained or instructed and apprentices are only permitted to work on the device under the supe...

Страница 6: ...nmental protection and are knowledgeable regarding the assembly instructions and or operating instructions and especially are familiar with the safety instructions contained therein All safety and war...

Страница 7: ...ing model use supplied stoppers for cable inlets cut off necessary cable inlets respectively to the cable diameter Or alternative use cable inlet for cable glands Any cable ducts openings not used mus...

Страница 8: ...s ing parts in metal terminal space covers and housing casings Commissioning is only permissible after these screws have been properly attached Metal screwed connections are not permitted in plastic h...

Страница 9: ...low level of air noise this noise may be dominant in the lower speed range due to the occurrence of resonance 5 5 Motor protection The motor can be protected by connecting thermostats TB When multipl...

Страница 10: ...sible to connect outputs of several devices to each other The function of the signal output A1 Analog Out 1 can be determined by DIP8 DIP 8 OFF Constant voltage 10 V for external potentiometer factory...

Страница 11: ...ostics faults Fault indicated for line fault blown internal semiconductor fuse broken controller internal voltage supply overheating by the motor thermostats TB connected When switching off via enable...

Страница 12: ...ng Potentiometer Pband without function Potentiometer n min Minimal output voltage basic speed Setting range 0 100 n min takes priority if over n max Potentiometer n max Maximal output voltage speed l...

Страница 13: ...e goes continuously with reduction of the regulating variable down to 0 cutoff below approx 2 regulating variable Without minimum speed cut OFF DIP 5 OFF factory setting If minimal speed n min is adju...

Страница 14: ...etting range Output voltage from approx 0 100 of connected line voltage or in range of settings n min up to n max Signal to E1 E1 GND 14 02 2008 v_signal_e1 vsd alternatively Control by external signa...

Страница 15: ...teps DIP2 OFF for setting via external signall Switchover between two steps via external potential free contact possible Step 1 low speed When there is no input signal connected to the input terminal...

Страница 16: ...rminals 11 12 bridged Motor fault Tripping of connected thermostat or break between terminals TB The unit cuts out and does not switch on again Check motor and connection then reset F Motor protection...

Страница 17: ...approx 0 2 A Voltage supply e g for sensors 24 V 20 Imax 80 mA Output 0 10 V Imax 10 mA short circuit proof Max permissible ambient temperature 55 C Min permissible ambient temperature 0 C if mains v...

Страница 18: ...tern with internal thermostats M 1 PE U2 U1 TB TB 2 14 01 2010 v_p et20sd VSD E1 10k 1 Line 1 120 277 V 50 60 Hz 2 1 Motor with internal thermostats 3 Input 0 10 V potentiometer outside connected at f...

Страница 19: ...IF CLAIMING UNDER TERMS OF GUARANTEE Please return the complete product carriage paid to your original supplier or nearest Vent Axia Centre by post or personal visit Please ensure that it is adequate...

Отзывы: