Danger owing to electric current

Danger owing to electric current or voltage.

Information

Important information and advice for user.

2.3 Product safety

The device conforms to the state of the art at the time of delivery and is fundamentally considered to

be reliable. The device and its accessories must only be used in a

awless condition and installed and

operated in compliance with the assembly instructions and/or operating instructions. Operating out-

side the device's technical speci

cations (

F

rating plate and attachment / technical data) can lead to a

defect in the device and additional damage!

In the case of a malfunction or a failure of the equipment check all functions with alarms in

order to prevent injury to persons or property. Note possibility of back-up operation. If used in

intensive animal environments, any malfunctions in the air supply must be detected as soon

as possible to prevent the development of a life-threatening situation for the animals. The

design and installation of the system must comply with local regulations and directives. In

Germany these include DIN VDE 0100, the animal protection and the keeping of working

animals ordinance and the pig-keeping ordinance etc. Also note the instructions of AEL, DLG,

VdS.

2.4 Requirements placed on the personnel / due diligence

Persons entrusted with the planning, installation, commissioning and maintenance and servicing in

connection with the frequency inverter must have the corresponding quali

cations and skills for these

jobs.

In addition, they must be knowledgeable about the safety regulations, EU directives, rules for the

prevention of accidents and the corresponding national as well as regional and in-house regulations.

Personnel to be trained or instructed and apprentices are only permitted to work on the device under

the supervision of an experienced person. This also applies to personnel undergoing general training.

Comply with the legal minimum age.

2.5 Start-up and during operation

Attention!

During commissioning, unexpected and hazardous conditions can arise in the entire installation due to

defective adjustments, defective components or incorrect electrical connections. Remove all persons

and objects from the hazardous area.

During operation, the device must be closed or installed in a control cabinet. Fuses may only be

replaced by new ones and must not be repaired or bypassed. The data for the maximum line fuse are

to be considered absolutely (

F

Technical data). Use only fuses speci

ed in schematic diagrams.

Any faults detected in the electric system/modules/operating equipment must be corrected

immediately. If these faults are not corrected, the device/system is potentially very dangerous. The

device/system must therefore not be operated when it is faulty.

2.6 Work on the device

Information

Installation, electrical connection, and start-up operation may only be carried out by an

electrical specialist in accordance with electrotechnical regulations (e.g. DIN EN 50110 or DIN

EN 60204).

Danger owing to electric current

It is forbidden to carry out work on electrically live parts. The enclosure rating of the device

when open is IP 00! It is possible to inadventently touch components carrying hazardous

voltages!

The safe isolation from the supply must be checked using a

two-pole

voltage detector.

Installation and Wiring Instructions

Speed controller

Safety information

L-BAL-E097-GB 1002 Index 001

Part.-No. 00163342-GB

4/18

Содержание 103 14 120

Страница 1: ...Speed controller For variable voltage 1 fans Installation and Wiring Instructions Software version D1349A from Version 1 00 L BAL E097 GB 1002 Index 001 Part No 00163342 GB english...

Страница 2: ...6 4 4 Installation location for agriculture 7 4 5 Temperature in uences during commissioning 7 5 Electrical installation 7 5 1 Safety precautions 7 5 2 EMC compatible installation 7 5 2 1 Motor feede...

Страница 3: ...signal and speed 14 9 3 Operation with two variable output voltages two steps 14 10 Diagnostics Faults 15 10 1 If controller doesn t work correctly 15 11 Enclosure 16 11 1 Technical data 16 11 2 Conn...

Страница 4: ...ept no liability for damage caused by misuse incorrect use improper use or as a consequence of unauthorized repairs or modi cations 1 4 Copyright These operating instructions contain copyright protect...

Страница 5: ...n of accidents and the corresponding national as well as regional and in house regulations Personnel to be trained or instructed and apprentices are only permitted to work on the device under the supe...

Страница 6: ...nmental protection and are knowledgeable regarding the assembly instructions and or operating instructions and especially are familiar with the safety instructions contained therein All safety and war...

Страница 7: ...ing model use supplied stoppers for cable inlets cut off necessary cable inlets respectively to the cable diameter Or alternative use cable inlet for cable glands Any cable ducts openings not used mus...

Страница 8: ...s ing parts in metal terminal space covers and housing casings Commissioning is only permissible after these screws have been properly attached Metal screwed connections are not permitted in plastic h...

Страница 9: ...low level of air noise this noise may be dominant in the lower speed range due to the occurrence of resonance 5 5 Motor protection The motor can be protected by connecting thermostats TB When multipl...

Страница 10: ...sible to connect outputs of several devices to each other The function of the signal output A1 Analog Out 1 can be determined by DIP8 DIP 8 OFF Constant voltage 10 V for external potentiometer factory...

Страница 11: ...ostics faults Fault indicated for line fault blown internal semiconductor fuse broken controller internal voltage supply overheating by the motor thermostats TB connected When switching off via enable...

Страница 12: ...ng Potentiometer Pband without function Potentiometer n min Minimal output voltage basic speed Setting range 0 100 n min takes priority if over n max Potentiometer n max Maximal output voltage speed l...

Страница 13: ...e goes continuously with reduction of the regulating variable down to 0 cutoff below approx 2 regulating variable Without minimum speed cut OFF DIP 5 OFF factory setting If minimal speed n min is adju...

Страница 14: ...etting range Output voltage from approx 0 100 of connected line voltage or in range of settings n min up to n max Signal to E1 E1 GND 14 02 2008 v_signal_e1 vsd alternatively Control by external signa...

Страница 15: ...teps DIP2 OFF for setting via external signall Switchover between two steps via external potential free contact possible Step 1 low speed When there is no input signal connected to the input terminal...

Страница 16: ...rminals 11 12 bridged Motor fault Tripping of connected thermostat or break between terminals TB The unit cuts out and does not switch on again Check motor and connection then reset F Motor protection...

Страница 17: ...approx 0 2 A Voltage supply e g for sensors 24 V 20 Imax 80 mA Output 0 10 V Imax 10 mA short circuit proof Max permissible ambient temperature 55 C Min permissible ambient temperature 0 C if mains v...

Страница 18: ...tern with internal thermostats M 1 PE U2 U1 TB TB 2 14 01 2010 v_p et20sd VSD E1 10k 1 Line 1 120 277 V 50 60 Hz 2 1 Motor with internal thermostats 3 Input 0 10 V potentiometer outside connected at f...