background image

2

SAVE THESE  INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE

IMPORTANT SAFETY INSTRUCTIONS

When using an electrical appliance, basic precautions should always be followed, including the following:

GENERAL INFORMATION   .  .  .  .  .  .  .  .  . 3

 

T

OOL

 L

ISTING

.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3

 

W

ORKING

 

WITH

 P

LASTIC

 T

UBING

.  .  .  .  .  .  .  .  .  .  .  .  . 3

WALL INLET INSTALLATION .  .  .  .  .  .  .  . 3

V600W VACUSWEEP® 
INLET VALVE INSTALLATION   .  .  .  .  .  . 4-6

 

C

ONNECTION

 

FROM

 B

ELOW

  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4

 

C

ONNECTION

 

FROM

 B

EHIND

.  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5

 

C

ONNECTION

 

IN

 

A

 W

ALL

  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6

POWER UNIT INSTALLATION   .  .  .  .  .  . 7-9

 

L

OCATING

 

THE

 P

OWER

 U

NIT

  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7

 

C

HANGING

 I

NTAKE

 L

INE

 D

IRECTION

  .  .  .  .  .  .  .  .  .  .  . 7

 

M

OUNTING

 

THE

 P

OWER

 U

NIT

  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8

 

F

ITTING

 M

AIN

 L

INE

 

TO

 P

OWER

 U

NIT

.  .  .  .  .  .  .  .  .  .  . 9

GROUNDING INSTRUCTIONS  .  .  .  .  .  .  . 9

 

W

IRING

.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 9

OPERATION AND MAINTENANCE .  .  .10-11

 

W

HEN

 

TO

 C

HANGE

 B

AG

 

OR

 E

MPTY

 D

EBRIS

 P

AIL

  .  .  .  .  10

 

H

OW

 

TO

 E

MPTY

 D

EBRIS

 P

AIL

 

 (600VF 

AND

 650VF P

OWER

 U

NITS

 

ONLY

).  .  .  .  .  .  .  10

 

D

ISPOSABLE

 B

AG

 R

EPLACEMENT

 

 (500VF 

P

OWER

 U

NIT

 O

NLY

) .  .  .  .  .  .  .  .  .  .  .  .  .  10

 

P

ERMANENT

 F

ILTER

 (600VF 

AND

 650VF P

OWER

 U

NITS

 

ONLY

).  .  .  .  .  .  .  10

 

R

EMOVAL

 

AND

 I

NSTALLATION

 

OF

 P

ERMANENT

 F

ILTER

 (600VF 

AND

 650VF P

OWER

 U

NITS

 

ONLY

).  .  .  .  .  .  .  10

 

R

EMOVAL

 

AND

 I

NSTALLATION

 

OF

 HEPA F

ILTER

 (650VF 

P

OWER

 U

NIT

 

ONLY

)  .  .  .  .  .  .  .  .  .  .  .  .  .  11

 

M

OTOR

 F

OAM

 F

ILTER

 (A

LL

 

UNITS

) .  .  .  .  .  .  .  .  .  .  .  11

TROUBLESHOOTING GUIDE.  .  .  .  .  .  .  12

SERVICE PARTS   .  .  .  .  .  .  .  .  .  .  .  .  .  13

WARRANTY  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  14

TABLE OF CONTENTS

WARNING

To reduce the risk of fire, electric shock or injury:

1.

  Do not use on wet surfaces or outdoors.

2.

  Do not vacuum liquids or fine powders (such as drywall dust).

3.

  Do not use to pick up flammable or combustible liquids such 

as gasoline or use in areas where they may be present.

4.

  Do not pick up anything that is burning or smoking, such as 

cigarettes, matches, or hot ashes.

5.

  Do not allow to be used as a toy. Close attention is necessary 

when used by or near children.

6.

 Use only as described in this manual. Use only 

manufacturer's recommended attachments.

7.

  Keep hair, loose clothing, fingers and all parts of body away 

from openings and moving parts.

8.

  Turn off all controls before unplugging.

9.

  Use extra care when cleaning on stairs.

10.

 Do not handle plug or appliance with wet hands.

11.

 Do not use with damaged cord or plug. If appliance is not 

working as it should, if it has been dropped, damaged, 
left outdoors, or dropped into water, return it to a Service 
Center.

12.

 Keep your work area well lighted.

13.

 Connect to a properly grounded outlet only. See grounding 

instructions shown on page 9.

14.

 When performing installation, servicing or cleaning the unit, 

it is recommended to wear safety glasses and gloves.

15.

 

When applicable local regulations comprise more 
restrictive installation and/or certification requirements, 
the aforementioned requirements prevail on those of this 
document and the installer agrees to conform to these at 
his own expenses.

CAUTION

1.

  Do not put any object into openings. Do not use with any 

opening blocked; keep free of dust, lint, hair and anything 
that may reduce air flow.

2.

  Ensure air flows freely and exhausts unobstructed from top 

or side outlet.

3.

  Do not use without filter (or filters, according to the model) 

in place.

4.

  Do not use to blow leaves or debris.

5.

  Do not place any object on top of the unit.

6.

  Do not install the unit horizontally.

7.

  Do not use the pail as a wash bucket.

8.

  Do not use the pail as a stool.

9.

  Avoid picking up sharp objects. 

10.

 This appliance is for use on a standard 120 VAC, dedicated 

15-amp branch circuit. 

11.

 Do not unplug the unit by pulling on cord. To unplug, grasp 

the plug, not the cord.

12.

 Store your vacuum cleaner indoors in a clean, dry area, and 

away from extreme temperatures.

13.

 Any servicing other than that recommended in this manual 

should be performed by an authorized service facility.

14.

 We recommend that your unit be inspected by a specialized 

technician once a year.

Содержание 500VF

Страница 1: ...SIDENTIAL USE ONLY REGISTER YOUR PRODUCT ONLINE AT WWW VENMAR CA 30042507B AB0039 CENTRAL VACUUM POWER UNITS MODELS SFDB DK SFDB DL AND SFDB DM VENMAR VENTILATION ULC DRUMMONDVILLE QU BEC WWW VENMAR C...

Страница 2: ...r loose clothing fingers and all parts of body away from openings and moving parts 8 Turn off all controls before unplugging 9 Use extra care when cleaning on stairs 10 Do not handle plug or appliance...

Страница 3: ...ubing and the outside of the plastic tubing or mounting plate tubing ring Twist both pieces while joining them to evenly spread the glue Allow 5 minutes for the cement to set in flexible tubing SECURE...

Страница 4: ...it OFF Wrap a piece of wire string around the pipe Using the wire string to temporarily hold the pipe and elbow in place insert the V600W VacuSweep inlet valve into the cabinet base and elbow DO NOT G...

Страница 5: ...he V600W VacuSweep inlet valve by sliding the low voltage wire into wire clips Turn the power to the vacuum unit ON to test the connection After successful completion of the test turn power to the vac...

Страница 6: ...2XS ontoasectionof2 centralvacuum tube Make the terminal connections to the V600W VacuSweep inlet valve by sliding the low voltage wire into wire clips Turn the power to the vacuum unit ON to test the...

Страница 7: ...e the screw tightening the bag adapter and intake elbow junction Disassemble the bag adapter from the intake elbow and set aside with its screw and nut Allunits Disassemble the intake elbow from the b...

Страница 8: ...ing bracket on the wall through upper and lower mounting holes Hang power unit onto wall mounting bracket Ensure the back brackets of the power unit are engaged with corresponding wall bracket fingers...

Страница 9: ...ic current to reduce the risk of electric shock This appliance is equipped with a cord having an equipment grounding conductor and grounding plug The plug must be plugged into an appropriate outlet th...

Страница 10: ...emove the disposable bag release both latches on sides of the unit by pulling out and then pushing up Remove the pail from unit Grasp the edges of the bag collar and pull down The bag will slide off e...

Страница 11: ...tor foam safety filter located at the top of the vacuum chamber provides protection against dirt being pulled into the motor if the disposable bag or permanent filter should accidentally be torn This...

Страница 12: ...and over the opposite end of the hose When you can feel the suction increase hold your hand over the hose end for a few seconds and then quickly remove your hand This procedure repeated several times...

Страница 13: ...epot for all replacement parts and repairs 4 11 7 12 KEY NO PART NO DESCRIPTION 500VF 600VF 650VF 1 S10941410 650VF TOP CAP ASSEMBLY INCLUDING ITEM 5 UPPER PART 1 S10941412 500VF AND 600VF TOP CAP ASS...

Страница 14: ...any implied warranty is limited to the period as specified for the express warranty VENMARVENTILATION S OBLIGATIONTO REPAIR OR REPLACE ATVENMARVENTILATION S OPTION SHALL BETHE PURCHASER S SOLE AND EXC...

Отзывы: