background image

11

REMOVAL AND INSTALLATION
OF HEPA FILTER
(650VF POWER UNIT ONLY) 

NOTE:  This is a disposable HEPA filter; do not attempt to 
 

 

wash it since this will damage it.

This HEPA filter should be replaced every 5 years. Proceed as 
follow:

 If installed, detach the exhaust line from the top of the unit.

 Disassemble upper part from lower part top cap assembly 

by pushing on the 4 retaining tabs (one by one) located on 
the lower part and pulling on upper part to disengage it. 

  NOTE: A small flat blade screwdriver  can also be used to 

 

pry on the 4 retaining tabs, as shown in illustration 

A

 

 

at the bottom of the page.

 Discard the used filter and replace with a new one (part 

no. S10941416). Be sure to install it with the gasket on top as 

shown in illustration

 B

 (at the botton of the page), then snap 

in place the upper part of the top cap. If need be, reconnect 
the exhaust line to the top cap.

MOTOR FOAM FILTER
(ALL UNITS)

A motor foam safety filter, located at the top of the vacuum 
chamber provides protection against dirt being pulled into 
the motor if the disposable bag or permanent filter should 
accidentally be torn. This filter should be checked and cleaned 
if necessary when replacement bag is installed (500VF unit 
only), or when permanent filter is removed (600VF and 650VF 
units only). Simply brush filter clean. If the filter is excessively 
soiled, hand wash in a water and mild detergent solution, rinse 
and let it dry 

completely

 on a flat surface before reinstalling.

REMOVING MOTOR 
FOAM FILTER

Remove the debris pail 
and disposable bag or 
permanent filter. Lift the 
center of the wire retaining 

 

the motor foam filter and 
slide the filter out of its 
location. 

REINSTALLING 
MOTOR FOAM 
FILTER

To reinstall the motor foam 

 

filter, reverse the steps 
described above.

OPERATION AND MAINTENANCE (

CONT

'

D

)

CAUTION

Operating the power unit without the motor foam  
filter will void the warranty.

AD0086

    WARNING

!

Risk of warm surfaces and sharp edges. It is 
recommended to wear safety gloves while handling 
this HEPA filter.

4 X

AR0053

A

B

Содержание 500VF

Страница 1: ...SIDENTIAL USE ONLY REGISTER YOUR PRODUCT ONLINE AT WWW VENMAR CA 30042507B AB0039 CENTRAL VACUUM POWER UNITS MODELS SFDB DK SFDB DL AND SFDB DM VENMAR VENTILATION ULC DRUMMONDVILLE QU BEC WWW VENMAR C...

Страница 2: ...r loose clothing fingers and all parts of body away from openings and moving parts 8 Turn off all controls before unplugging 9 Use extra care when cleaning on stairs 10 Do not handle plug or appliance...

Страница 3: ...ubing and the outside of the plastic tubing or mounting plate tubing ring Twist both pieces while joining them to evenly spread the glue Allow 5 minutes for the cement to set in flexible tubing SECURE...

Страница 4: ...it OFF Wrap a piece of wire string around the pipe Using the wire string to temporarily hold the pipe and elbow in place insert the V600W VacuSweep inlet valve into the cabinet base and elbow DO NOT G...

Страница 5: ...he V600W VacuSweep inlet valve by sliding the low voltage wire into wire clips Turn the power to the vacuum unit ON to test the connection After successful completion of the test turn power to the vac...

Страница 6: ...2XS ontoasectionof2 centralvacuum tube Make the terminal connections to the V600W VacuSweep inlet valve by sliding the low voltage wire into wire clips Turn the power to the vacuum unit ON to test the...

Страница 7: ...e the screw tightening the bag adapter and intake elbow junction Disassemble the bag adapter from the intake elbow and set aside with its screw and nut Allunits Disassemble the intake elbow from the b...

Страница 8: ...ing bracket on the wall through upper and lower mounting holes Hang power unit onto wall mounting bracket Ensure the back brackets of the power unit are engaged with corresponding wall bracket fingers...

Страница 9: ...ic current to reduce the risk of electric shock This appliance is equipped with a cord having an equipment grounding conductor and grounding plug The plug must be plugged into an appropriate outlet th...

Страница 10: ...emove the disposable bag release both latches on sides of the unit by pulling out and then pushing up Remove the pail from unit Grasp the edges of the bag collar and pull down The bag will slide off e...

Страница 11: ...tor foam safety filter located at the top of the vacuum chamber provides protection against dirt being pulled into the motor if the disposable bag or permanent filter should accidentally be torn This...

Страница 12: ...and over the opposite end of the hose When you can feel the suction increase hold your hand over the hose end for a few seconds and then quickly remove your hand This procedure repeated several times...

Страница 13: ...epot for all replacement parts and repairs 4 11 7 12 KEY NO PART NO DESCRIPTION 500VF 600VF 650VF 1 S10941410 650VF TOP CAP ASSEMBLY INCLUDING ITEM 5 UPPER PART 1 S10941412 500VF AND 600VF TOP CAP ASS...

Страница 14: ...any implied warranty is limited to the period as specified for the express warranty VENMARVENTILATION S OBLIGATIONTO REPAIR OR REPLACE ATVENMARVENTILATION S OPTION SHALL BETHE PURCHASER S SOLE AND EXC...

Отзывы: