Open the wall inlet cover and insert the end of the hose into the 
inlet to turn on the vacuum. 

For non-switched hoses, inserting the hose automatically turns 
on the power unit; removing the hose shuts off the power unit. 
Some hoses have switches which can be used to activate 
power unit. The ON/OFF switch located on the power unit 
needs to be kept in the OFF position.

As you vacuum, dirt and dust are carried to the power unit 
where they remain in a bag or in the debris pail (according to 
the power unit model).

Use the cleaning tools as you would for any other vacuum 
cleaner. Avoid picking up very large debris or lengthy as these 
kinds of objects may become lodged in the hose or tubing.

WHEN TO CHANGE BAG* OR EMPTY 
DEBRIS PAIL

With a 6 U.S. gallons (22.7 liters) capacity, under normal 
conditions the bag/debris pail requires changing/emptying 
approximately twice a year. If the bag/debris pail is full, you will 
notice a reduced suction from the system. Unless this loss of 
suction is caused by a blockage in the system, changing the 
bag or emptying the debris pail will solve the problem.

NOTE:  Even if not filled to capacity, if the bag seems tightly 
 

stretched when removing the debris pail, changing 

 

the bag will prevent it from tearing.

* Only 500VF unit is equipped with a disposable bag (391C).

HOW TO EMPTY DEBRIS PAIL (600VF 
AND 650VF POWER UNITS ONLY)

To empty the debris pail, release both latches on sides of the 
unit by pulling out and then pushing up. Holding the pail by the 
latches, lower it from unit. Carry pail to trash receptacle and 
dispose of debris. Put the pail back in its place.

DISPOSABLE BAG REPLACEMENT
(500VF POWER UNIT ONLY)

 To remove the disposable bag, release both latches on 

sides of the unit by pulling out and then pushing up. Remove 
the pail from unit. Grasp the edges of the bag collar and pull 
down. The bag will slide off easily. Do not pull on the bag.

 Unfold the new bag.

 Grasp collar where indicated on the new bag and insert over 

bag adapter. Be careful not to tear the bag. Ensure the collar 
is positioned between the taper ring and the bag stopper on 
the bag adapter (see illustration below). Put the pail back in 
its place.

PERMANENT FILTER
(600VF AND 650VF POWER UNITS 
ONLY)

This filter protects the motor and stops small particles from 
escaping to the outside of the power unit wihout the need to 
replace it. The filter cleans itself by moving up when the power 
unit starts, and dropping down when the unit is turned off. 
Under normal use, there is no need to maintenance this filter.
It is possible to remove it to inspect the motor foam filter, or 
to replace it if ever it has been damaged (by sharp debris, for 
example). 

REMOVAL AND INSTALLATION OF 
PERMANENT FILTER (600VF AND 
650VF POWER UNITS ONLY)

 Remove the pail from unit. 

To remove the permanent 
filter, use pull tab (

A

located on edge of filter to 
pull and loosen filter from 
inlet chamber wall. Squeeze  
from both sides of the filter 
to the center of the housing.
Then, carefully remove it 
from the unit.

 Squeeze the filter in order 

to move it past the inlet 
opening (

B

) Let the filter 

bear against the unit wall 
by releasing the pressure. 
Make sure to place the rigid 
ring in its groove to ensure 
proper sealing.

 

NOTE: Make sure the filter is 

 

 

installed so that the pull

  

tab 

(

A

) is accessible 

 

 

for future filter removal.

OPERATION AND MAINTENANCE

AO0081

T

APER

 

RING

B

AG

 

STOPPER

AA0005

A

AD0084

A

AD0085

B

CAUTION

Be sure to reinstall filter properly. Appropriate 
location is critical to insure proper protection of 
the motor.

Содержание 500VF

Страница 1: ...SIDENTIAL USE ONLY REGISTER YOUR PRODUCT ONLINE AT WWW VENMAR CA 30042507B AB0039 CENTRAL VACUUM POWER UNITS MODELS SFDB DK SFDB DL AND SFDB DM VENMAR VENTILATION ULC DRUMMONDVILLE QU BEC WWW VENMAR C...

Страница 2: ...r loose clothing fingers and all parts of body away from openings and moving parts 8 Turn off all controls before unplugging 9 Use extra care when cleaning on stairs 10 Do not handle plug or appliance...

Страница 3: ...ubing and the outside of the plastic tubing or mounting plate tubing ring Twist both pieces while joining them to evenly spread the glue Allow 5 minutes for the cement to set in flexible tubing SECURE...

Страница 4: ...it OFF Wrap a piece of wire string around the pipe Using the wire string to temporarily hold the pipe and elbow in place insert the V600W VacuSweep inlet valve into the cabinet base and elbow DO NOT G...

Страница 5: ...he V600W VacuSweep inlet valve by sliding the low voltage wire into wire clips Turn the power to the vacuum unit ON to test the connection After successful completion of the test turn power to the vac...

Страница 6: ...2XS ontoasectionof2 centralvacuum tube Make the terminal connections to the V600W VacuSweep inlet valve by sliding the low voltage wire into wire clips Turn the power to the vacuum unit ON to test the...

Страница 7: ...e the screw tightening the bag adapter and intake elbow junction Disassemble the bag adapter from the intake elbow and set aside with its screw and nut Allunits Disassemble the intake elbow from the b...

Страница 8: ...ing bracket on the wall through upper and lower mounting holes Hang power unit onto wall mounting bracket Ensure the back brackets of the power unit are engaged with corresponding wall bracket fingers...

Страница 9: ...ic current to reduce the risk of electric shock This appliance is equipped with a cord having an equipment grounding conductor and grounding plug The plug must be plugged into an appropriate outlet th...

Страница 10: ...emove the disposable bag release both latches on sides of the unit by pulling out and then pushing up Remove the pail from unit Grasp the edges of the bag collar and pull down The bag will slide off e...

Страница 11: ...tor foam safety filter located at the top of the vacuum chamber provides protection against dirt being pulled into the motor if the disposable bag or permanent filter should accidentally be torn This...

Страница 12: ...and over the opposite end of the hose When you can feel the suction increase hold your hand over the hose end for a few seconds and then quickly remove your hand This procedure repeated several times...

Страница 13: ...epot for all replacement parts and repairs 4 11 7 12 KEY NO PART NO DESCRIPTION 500VF 600VF 650VF 1 S10941410 650VF TOP CAP ASSEMBLY INCLUDING ITEM 5 UPPER PART 1 S10941412 500VF AND 600VF TOP CAP ASS...

Страница 14: ...any implied warranty is limited to the period as specified for the express warranty VENMARVENTILATION S OBLIGATIONTO REPAIR OR REPLACE ATVENMARVENTILATION S OPTION SHALL BETHE PURCHASER S SOLE AND EXC...

Отзывы: