background image

L-3113 (10-15-22)

PROSTOP-E

ENGLISH: 1-16

QUAD NOZZLE BODY

pentair.com

INSTALLATION AND  

OPERATION MANUAL

©2022. All Rights Reserved.

Содержание Hypro ProStop-E Quad 4216N-3403VPSQ

Страница 1: ...L 3113 10 15 22 PROSTOP E ENGLISH 1 16 QUADNOZZLEBODY pentair com INSTALLATIONAND OPERATIONMANUAL 2022 All Rights Reserved...

Страница 2: ...his symbol in this manual look for one of the following signal words and be alert to the potential for personal injury indicates a hazard which if not avoided will result in death or serious injury in...

Страница 3: ...42 36 1 3 69 93 7 4216N 3403VPSQ 3 4 Pipe 1 42 36 1 3 69 93 7 4216N 3409VPSQ 28 mm 1 47 37 5 3 69 93 7 4216N 3404VTPSQ 1 Pipe Tall Stem 1 69 42 8 3 91 99 3 CONDITION PRESSURE DROP FLOW 1 outlet open 5...

Страница 4: ...tiv Connector 15343999 A tab between terminals D E on the BLU side prevents the cables from being installed backwards Unused connector ports need to be plugged for protection and 120 Ohm resistor is r...

Страница 5: ...BLU SIDE E D C B A NO SLOT BETWEEN D E ON GRN SIDE CONNECTOR SIGNAL CABLE COLOR WIRE GAUGE BLU SIDE PIN LOCATIONS GRN SIDE PIN LOCATIONS 12 V RED 14 AWG E A CAN HIGH YELLOW 20 AWG D B ADDRESS LINES G...

Страница 6: ...ent to the global address 255 so that all devices on the bus are placed in the mapping mode simultaneously Upon seeing a signal on the address line input the device will initiate an address claim proc...

Страница 7: ...request a status response from one Nozzle Body PCM 4 corresponds to the Nozzle Bodies at addresses 150 165 PCM 6 corresponds to addresses 166 181 and so on All devices in the PCM s range will receive...

Страница 8: ...device at address 118 8 x 157 173 Byte 4 Bit 3 0 Valve control for device at address 118 8 x 158 174 Bit 7 4 Valve control for device at address 118 8 x 159 175 Byte 5 Bit 3 0 Valve control for device...

Страница 9: ...from the Nozzle Body at address 180 the ECU would send the following message The Nozzle Body at address 180 would then send a response message that would look like the following GENERAL COMMANDS MESSA...

Страница 10: ...00BAC701h 8 PCM 10 Set devices 198 213 Request response from 199 00BB01C7h 1 PCM 11 Status for device 199 00BCD701h 8 PCM 12 Set devices 214 229 Request response from 215 00BD01D7h 1 PCM 13 Status for...

Страница 11: ...Body module at address 150 the ECU would send the following message The Nozzle Body module with firmware version 1 02 would then send a response message that would look like the following MESSAGE BYT...

Страница 12: ...with clean water to expel other debris before reattaching valve Prevent subsequent contamination by utilizing or installing line strainers in the boom Loss of communication with task controller Verify...

Страница 13: ...TY PART 1 A Kit Stem Bottom Clamp 1 pipe 1 3430 0901 1 B Kit Stem Bottom Clamp 20mm 1 3430 0902 1 C Kit Stem Bottom Clamp 22mm 1 3430 0903 1 D Kit Stem Bottom Clamp 25mm 1 3430 0904 1 E Kit Stem Botto...

Страница 14: ...14 L 3113 10 15 22 THIS PAGE HAS BEEN LEFT BLANK INTENTIONALLY...

Страница 15: ...ber date of purchase and from whom you purchased your product Hypro may request additional information and may require a sketch to illustrate the problem Contact the appropriate Hypro Service Departme...

Страница 16: ...eir respective owners Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notice Pentair is an equal opportunity employer...

Отзывы: