LOCATING THE POWER UNIT

•  Locate the power unit away from the general living area in 

an accessible location for cleaning and maintenance.

•  Locate the power unit within 6 feet of a grounded electrical outlet. 

The power unit requires a 120 VAC power source, dedicated 
15-amp branch circuit.

•  Do not locate the power unit close to a source of extreme 

heat (i.e.: water heater) or in an area with a high ambient 
temperature (i.e.: attic, furnace room).

•  If the power unit is located in a closet or a small utility 

room, make sure the area is well-ventilated (e.g.: with door 
louvers).

CHANGING INTAKE LINE DIRECTION

The intake line connects to the right side of the unit. However, 
it is possible to change this configuration; to connect the intake 

line to the left side of the unit, follow these steps:

 

 Remove debris pail from power unit by releasing both latches 

on sides of the unit, pulling them out and then pushing up. 
Detach the pail from unit. 

 

500VF only

: Grasp 

the edges of the bag 
collar and pull down; 
the bag will slide off 
easily. 

Do not pull on 

the bag

. Set aside the 

bag.

 

500VF only

: Using a 

Phillips screwdriver 
no. 2, remove the 
screw tightening the 
bag adapter and 
intake elbow junction.
Disassemble the 
bag adapter from the 
intake elbow and set 
aside with its screw 
and nut.

 

All units

: Disassemble

the intake elbow from 
the back of the unit 
using a 3/8” socket 
to remove its both 
retaining nuts and 
screws. 

 

All units

: Flip the 

intake elbow 180°, 
then reassemble it to 
the unit, taking care to 
keep its gasket at its 
original position.

  NOTE: Ensure the 

gasket is not folded in 
order to prevent lack of suction and noise.

 

500VF only

Reassemble the bag 
adapter to the intake 
elbow. Align triangle 
with small inclined 
stud, then tighten 
the junction using 
the screw and nut 
previously removed in 

.

 

500VF only

: Put back 

in place the bag by 
grasping the edges of 
its collar and insert 
over bag adapter. Be 
careful not to tear the 
bag. Ensure the collar 
is positioned between 
the taper ring and the 
bag stopper on the 
bag adapter. 

 

All units

: Put the pail back in its place.

POWER UNIT INSTALLATION

AD0076

AO0078

500VF 

ONLY

AD0075

500VF 

ONLY

AD0077

AD0078

500VF 

ONLY

AO0080

500VF 

ONLY

T

APER

 

RING

B

AG

 

STOPPER

    WARNING

!

Do not install outdoors. Before being hung, rest the 
unit on a leveled surface to prevent the unit to fall 
down. When performing installation, servicing or 
cleaning the unit, it is recommended to wear safety 
glasses and gloves.

Содержание 500VF

Страница 1: ...SIDENTIAL USE ONLY REGISTER YOUR PRODUCT ONLINE AT WWW VENMAR CA 30042507B AB0039 CENTRAL VACUUM POWER UNITS MODELS SFDB DK SFDB DL AND SFDB DM VENMAR VENTILATION ULC DRUMMONDVILLE QU BEC WWW VENMAR C...

Страница 2: ...r loose clothing fingers and all parts of body away from openings and moving parts 8 Turn off all controls before unplugging 9 Use extra care when cleaning on stairs 10 Do not handle plug or appliance...

Страница 3: ...ubing and the outside of the plastic tubing or mounting plate tubing ring Twist both pieces while joining them to evenly spread the glue Allow 5 minutes for the cement to set in flexible tubing SECURE...

Страница 4: ...it OFF Wrap a piece of wire string around the pipe Using the wire string to temporarily hold the pipe and elbow in place insert the V600W VacuSweep inlet valve into the cabinet base and elbow DO NOT G...

Страница 5: ...he V600W VacuSweep inlet valve by sliding the low voltage wire into wire clips Turn the power to the vacuum unit ON to test the connection After successful completion of the test turn power to the vac...

Страница 6: ...2XS ontoasectionof2 centralvacuum tube Make the terminal connections to the V600W VacuSweep inlet valve by sliding the low voltage wire into wire clips Turn the power to the vacuum unit ON to test the...

Страница 7: ...e the screw tightening the bag adapter and intake elbow junction Disassemble the bag adapter from the intake elbow and set aside with its screw and nut Allunits Disassemble the intake elbow from the b...

Страница 8: ...ing bracket on the wall through upper and lower mounting holes Hang power unit onto wall mounting bracket Ensure the back brackets of the power unit are engaged with corresponding wall bracket fingers...

Страница 9: ...ic current to reduce the risk of electric shock This appliance is equipped with a cord having an equipment grounding conductor and grounding plug The plug must be plugged into an appropriate outlet th...

Страница 10: ...emove the disposable bag release both latches on sides of the unit by pulling out and then pushing up Remove the pail from unit Grasp the edges of the bag collar and pull down The bag will slide off e...

Страница 11: ...tor foam safety filter located at the top of the vacuum chamber provides protection against dirt being pulled into the motor if the disposable bag or permanent filter should accidentally be torn This...

Страница 12: ...and over the opposite end of the hose When you can feel the suction increase hold your hand over the hose end for a few seconds and then quickly remove your hand This procedure repeated several times...

Страница 13: ...epot for all replacement parts and repairs 4 11 7 12 KEY NO PART NO DESCRIPTION 500VF 600VF 650VF 1 S10941410 650VF TOP CAP ASSEMBLY INCLUDING ITEM 5 UPPER PART 1 S10941412 500VF AND 600VF TOP CAP ASS...

Страница 14: ...any implied warranty is limited to the period as specified for the express warranty VENMARVENTILATION S OBLIGATIONTO REPAIR OR REPLACE ATVENMARVENTILATION S OPTION SHALL BETHE PURCHASER S SOLE AND EXC...

Отзывы: