PART 3 - Technical manual
36
TROUBLESHOOTING - TECHNICIANS
Problem
Checklist
Repairs
VENDLET Basic does not work.
Is the green diode on the control unit under the bed
illuminated?
If not, check that the power is turned on and functional. Check that
the power cable is connected to the control unit.
Is the green diode on the hand control illuminated?
If not, make sure all cables are properly mounted and intact.
Replace the hand control.
Is there an acoustic alarm when a button on the hand
control is activated?
Reset the system by simultaneously pressing the two top buttons
on the hand control. You will hear 10 rhythmic beeps. Press and
hold the buttons until the beeping stops.
None of the above?
Contact a person with relevant training.
The bar starts but stops pulling
immediately afterwards.
Does the client weigh more than max. user weight?
If max user weight is exceeded acquire a VENDLET with higher user
weight.
Is part of the mattress or blanket rolled onto the bar
with the sheet?
Make sure only the turning sheet is rolled on to the bar.
Is the turning sheet attached correctly?
Make sure the turning sheet is placed OVER the bar.
One of the bars does not work.
Is the cable to the bar damaged?
If damaged, replace the cable for the bar.
Is the cable intact?
Switch the plugs of the two bars. If the same bar still does not
work, then the motor of that bar is defect. If the other bar is not
working, then the hand control or the control unit is defective. Re-
place the hand control. If this does not solve the problem, replace
the control unit.
Is the motor malfunctioning?
Replace the bar.
None of the above?
Contact a person with relevant training.
One or both bars does not
work when a load is applied.
Does the turning sheet run over the bar, cf. page 19
of the user manual?
If the sheet runs under the bar, the motor disconnects when load-
ed. This is a safety feature.
Switch the plugs of the two bars.
If the same bar still does not work, then the motor of that bar is
defective. If the other bar is not working, then the hand control or
the control unit is defective. Replace the hand control. If this does
not solve the problem, replace the control unit.
None of the above?
Contact a person with relevant training.
The hand control buttons are
not working.
Is the plug properly connected to the control unit?
Mount the plugs correctly in the control unit.
Is the cable damaged?
If yes - replace the hand control.
None of the above?
Contact a person with relevant training.
One of the bars only turn in
one direction.
Are all plugs properly connected on the control unit?
Mount the plugs correctly in the control unit.
Is the cable to the bars damaged?
If yes - replace the cable for the bar.
The bar stays up when
elevated.
Is the grey button missing?
If yes – install a new button
Is the grey button down?
If yes – replace the top lid on the corner post
None of the above
Replace the top lid on the corner post