Errors
the machine has a number of sensors for keeping the
various functional groups under control.
When an anomaly is detected, the machine displays the
type of fault and the machine (or part of it) is put out of
service.
the drinks that cannot be dispensed are represented
with a lowest brightness icon.
fault
rEaDiNg
show the last 16 faults, from the most to the least recent,
moving with the scroll bar.
-empty water
the selections are disabled and the pump is turned off
when the micro indicates that the tank is empty
-Full residues
the espresso-based selections are disabled when the
number of used pods set in the menu is reached .
-air-break
Fault not available on this model
the machine will stop working if, after 10 selections,
the microswitch has never notified the lack of water.
-
Volumetric meter (fan)
Failure to count the volumetric meters (cooling fans)
within a maximum time.
-Instant beverage boiler
the machine will stop working if after 10 minutes of
heating from start-up or from last selection the water in
the instant beverage boiler has not reached the tem-
perature.
-Machine board
absence of dialogue between the board and the touch-
screen
-coffee release
If after releasing the dose of ground coffee the mi-
croswitch of the doser detects presence of coffee in
the doser chamber, the coffee-based selections are
disabled.
-
-coffee unit -micro unit failure-
all the faults related to the coffee unit are controlled by
a “unit position” control microswitch.
the control microswitch is activated by the coffee unit
gear motor cam.
this fault indicates that during handling of the infuser
unit, the control micro is not operated within a certain
time limit.
it is possible that this fault is combined with another
positioning fault of the coffee unit
-coffee unit -start unit failure-
the gear motor is not capable of bringing the coffee
unit from the idle position to the infusion position.
-coffee unit -infuser unit failure-
the control microswitch indicates that the coffee unit is
not in the infusion position.
-coffee unit -dispensing unit failure-
During the infusion phase, the control microswitch indi-
cates the movement of the espresso unit.
-coffee unit -discharge unit failure-
at the end of the infusion the control microswitch
indicates that the coffee unit is not in the “used pod
discharge” position.
-coffee unit -idle unit failure-
the control microswitch indicates that the infuser unit
did not go back to the idle position at the end of the
discharge of the pod.
-empty coffee 1...2
If the ground coffee dose is not achieved within 15 sec-
onds after activation of the grinder, the coffee-based
selections are disabled.
-Grinder block
If the grinder fails to rotate or rotates too slowly, the
espresso-based selections are disabled while the
instant coffee-based selections remain available.
-RaM data
one or more areas of the RaM memory contain altered
data which was corrected with the default values.
the machine continues to work, but it is preferable to
proceed with the initialization as soon as possible.
-
Espresso boiler (C1)
the machine will stop working if after 10 minutes of
heating from start-up or from last selection the water in
the boiler has not reached the temperature.
-
Содержание KARISMA