© by N&W GLOBAL VENDING S.p.A.
31
02-2014 4535 00
i
NstaNt
bEvEragE
paramEtErs
coffEE
watEr
DosE
It is possible to decide the amount of water to be used in
the preparation of espresso coffee.
The value is in pulses of the flow meter (CDV); use “+”
and “-” to change the default value.
prE
-
iNfusioN
timE
the pre-infusion time (in tenths of a second) before the
infusion occurs.
prE
-
iNfusioN
DosE
Sets the amount of water (CDV) to be used during the
pre-infusion.
poD
squEEziNg
The squeezing is carried out by the upper piston which,
by mechanically compressing the pod, favours the expul-
sion of the water from the pod before discharging it into
the solid waste container.
-
ON: squeezing of the pod enabled
-
OFF: the pod is not squeezed.
c
offEE
DosE
Sets the amount of ground coffee (in grams) to be used
in the selection of choice
paD
prEssuriNg
It is possible to adjust the pressure exerted on the pod in
the infusion chamber.
changing this parameter can modify the presenta-
tion and quality of the dispensed drink.
The available profiles are:
-low
-Medium
-High
iNfusioN
DosE
Sets the amount of water (cdv) to be used during the
infusion.
g
riNDEr
only models with double espresso.
It allows the user to choose which grinder to use (type of
coffee) to deliver the coffee beverage.
i
NstaNt
bEvEragE
paramEtErs
iNstaNt
watEr
DosE
You can define (in CDV) the amount of water to be used
in the preparation of the beverage that uses the instant
powder
The value is in pulses of the flow meter (CDV); use “+”
and “-” to change the default value.
mixEr
(
blENDiNg
moDE
)
It is possible, for each selection, to set the mixing dura-
tion of each dose of water which forms the selection.
The duration can be set in two different modes:
-
absolute
which means independent from the solenoid valve
opening time.
the value of the mixing duration is set in terms of rela-
tive volumetric counter pulses (CDV)
-
relative
that is, by difference, more or less than the time of clos-
ing of the solenoid valve.
e.g.: if the value is 0, the mixing will stop exactly at the
same closing time of the solenoid valve.
the duration value of the mixing is always expressed in
tenths of a second.
iNstaNt
DosE
You can define (in g.) the amount of instant powder to be
used in the preparation of the beverage
DispENsEr
spEED
(
grams
./
sEc
.)
You can set the working speed of the motor-doser (in
grams per second) of the instant powder.
this value is used for calculating the time required for
dispensing the dose of powder in g.
stEp
DispENsiNg
the instant powder is dispensed in steps (which can be
set from 1 to 5) at the same time as the water dispens
-
ing.
the step dispensing allows for a better presentation of
the drink.
Содержание KARISMA