© by N&W GLOBAL VENDING S.p.A.
18
02-2014 4535 00
solid aNd liquid rEsiduEs
dischargE
Where possible,
you should
discharge the solid resi-
dues into bucket and connect the liquid residue con-
tainer to a standpipe.
liquiD
rEsiDuEs
connect the liquid residue container to a standpipe us-
ing the drain connector that plugs into the liquid residue
container
When this is not possible, it is preferable to use a bucket
to collect the residues from the tray.
to connect the liquid residue container to the drain con-
nector, drill the liquid residue container in the area of the
drain connector
Make sure that the liquid flows from the container without
obstacles.
soliD
rEsiDuEs
the discharge of the solid residues can be done directly
into a bucket using the solid residue slide supplied by
default, by inserting it into the drain hole.
-Remove the metal part of the setup for discharge on
bench
-Place the residue slide
-Place the solid residue container in a clean and pro-
tected location (closed cabinet), convenient for empty
-
ing and periodic cleaning.
3
1
2
Fig. 17
1- Preparing solid residue discharge on bench
2- Liquid residue container drain connector
3- Solid residue discharge slide (only models with discharge on
bench)
ElEcTrical coNNEcTioN
Given the power consumption, it is preferable to connect
the machine to a 400-415 V∿.3P+N+T three-phase line.
If a three-phase line is not available, the machine can
be connected to a 230-240V∿ single phase line, after
having qualified personnel check that it is properly sized
to handle the required load.
the machine is protected with 15 a fuses.
the machine is supplied without a power cord; use only
Ho5 VV-F or Ho5 VV H2 - F cords with a suitable sec-
tion or otherwise compliant with national legislation.
For the connection, ensure that details on the plate cor-
respond to those of the mains, in particular that the value
of the supply voltage falls within the recommended limits
for the connection points.
it is mandatory to use a switch, in accordance
with the rules of installation, located in an acces
-
sible position, which has characteristics suitable
for supporting the maximum load and ensures the
omnipolar disconnection from the power supply
under conditions of overvoltage category III and,
therefore, which protects the circuit against ground
faults, overloads and short circuits.
The device must be connected permanently.
The use of adapters, multiple plugs and/or exten
-
sion cables is forbidden.
The electrical safety of the machine is ensured only
when the machine is correctly connected to an ef-
ficient earthling system, as foreseen by the current
safety regulations.
It is necessary to verify this fundamental safety require-
ment and, in case of doubt, request an accurate check
of the system by qualified personnel.
the cable connection should be made to the appropriate
terminal board on the left side of the machine, respecting
the position of the phases shown in the diagrams.
For the cable connection it is necessary to remove the
left side panel (see side panel removal)