background image

English

- 1 - 

Thermo GSM Digital Thermostat User Manual

  Assembly  

Page  

3

  Dimensions  

Page  

4

  Connection diagrams  

Page  

4

  Safety warnings  

Page  

5

  Technical characteristics  

Page  

6

  Control elements / display indications  

Page  

7

  Initial start-up / Reset  

Page  

9

  Clock setting  

Page  

9

  Summer/winter operating mode  

Page   10

  Switching ON/OFF   

Page   11

  Advanced programming  

Page   12

  Advanced functions  

Page   19

  Regulation type  

Page   20

  GSM interface 

Page 

21

  Management of the thermostat 

Page 

25

  Management of alarms 

Page 

28

  Backup battery  

Page   35

  Reference standards  

Page   35

Index

Содержание Thermo GSM Bianco VE715900

Страница 1: ...Termostato Digitale Thermo GSM Manuale d Uso User Manual DIGITAL THERMOSTAT...

Страница 2: ......

Страница 3: ...l elements display indications Page 7 Initial start up Reset Page 9 Clock setting Page 9 Summer winter operating mode Page 10 Switching ON OFF Page 11 Advanced programming Page 12 Advanced functions P...

Страница 4: ...ttery NiMh type AA Comfort and control of consumptions are ensured both in winter and in summer heating air conditioning Integrated GSM module for the remote control of the thermostat by mobile phone...

Страница 5: ...temperature of the entire environment Avoid installing too close to doors windows heat sources direct sunlight radiation and positions with excess or total lack of aeration It is moreover recommended...

Страница 6: ...ish 4 Thermo GSM Digital Thermostat User Manual DIMENSIONS CONNECTION DIAGRAM 1 2 3 4 5 6 7 Ingresso per X Temp o DIG COM NA NC N L 230 1 2 230 V 3 4 5 6 7 Input for X temp or DIG COM NA NC N L 132 95...

Страница 7: ...ectronic devices non screened from radiofrequency signals electromedical devices pacemakers hearing aids etc 7 In the power supply network a bipolar disconnection must be present 8 A protection device...

Страница 8: ...scale 0 C 50 C internal probe 40 C 60 C external probe Measured and displayed temperature resolution 0 1 C Temperature adjustment range 2 0 C 50 C Measurement update every 20 seconds Measurement preci...

Страница 9: ...lected field 3 Key to decrease the setpoint to decrease the selected field To switch ON OFF the thermostat 4 Key to select winter operating modeg mode preset or summer operating mode clock setting use...

Страница 10: ...ture Field 8 Ambient temperature Field 9 Air conditioning activation Field 10 Heating activation Field 11 Clock Field 12 Receiving remote command via GSM Field 13 GSM connection Field 14 Unit of measu...

Страница 11: ...ING To set the clock and to switch ON OFF the DST automatic time change follow the steps below press the key for 3 seconds until the second setting appears on the display and starts flashing press key...

Страница 12: ...t is possible to set the time of the device by sending a text message command see Clock synchronization page 33 SUMMER WINTER OPERATING MODE To set the operating mode summer air conditioning or winter...

Страница 13: ...seconds until the symbol stops SWITCHING ON OFF ACTIVATION OF NIGHT TEMPERATURE REDUCTION It is possible to activate the night operating mode to reduce the temperature adjustment compared to the adjus...

Страница 14: ...perature reduction for night operating mode rid starting time setting of night operating mode INI ending time setting of night operating mode End keypad lock password system operating hours To enter a...

Страница 15: ...type only for winter operating mode In case of ON OFF regulation type the only parameter to be set is the differential Field 11 displays the writing dIF and on field 8 the value currently set starts f...

Страница 16: ...It is possible to set a safety temperature value antifreeze temperature to be maintained in case the thermostat is deactivated Field 11 dispalys the writing OFF and on field 8 the antifreeze temperat...

Страница 17: ...s case a change of the input status can be signalled by sending sms to a specific number for more further information see GSM interface on page 21 Field 11 dispalys the writing ESt and on field 16 the...

Страница 18: ...to confirm the choice GSM function page This page is related to the remote operation and it is described in detail in the GSM INTERFACE chapter on page 21 Minimum settable value as setpoint LO It is...

Страница 19: ...ting Set appears the symbol is on and on field 8 the reduction value starts flashing Press the keys and to increase or decrease the value and the key to confirm Settable values 1 0 5 0 C For example i...

Страница 20: ...to lock the keypad with a 3 digit password to prevent unauthorised people from doing setting modifications On field 11 the writing PAS appears Using the keys and to choose the desired password between...

Страница 21: ...5 hours To reset the counter press the key for about 3 seconds in the counter display menu ADVANCED FUNCTIONS Emergency regulation In winter operating mode if the sensor is failed the thermostat activ...

Страница 22: ...y the setpoint value The required parameters for the definition of this mode are the regulation band the regulation period The regulation band is centered on the setpoint and represents the temperatur...

Страница 23: ...nd vice versa B Information to display the temperatures measured by the internal and external probe if enabled to display the status of the external input if enabled C Alarms to receive an alarm of fa...

Страница 24: ...Inserting the SIM Card To remotely control the device with your mobile phone it is necessary to insert a SIM card in the specific slot which needs to be enabled for telephone traffic have the PIN code...

Страница 25: ...GSM signal the number 1 starts flashing to indicate that the number is storing in the position 1 of the phonebook call Thermo GSM the selected phone number to stored it in the first position of the ph...

Страница 26: ...without parameters For example PHONEBOOK Reply with a text message PHONEBOOK 1 2221234567 2 EMPTY 3 EMPTY 4 EMPTY 5 3001234567 Ring mode Attention the following procedure is recommended for expert use...

Страница 27: ...re the phone number 1 5 make a phone ring with the selected phone number to add it to the phonebook The caller will receive a text message from Thermo GSM confirming the number addition to exit withou...

Страница 28: ...eating or air conditioning operating mode can be set with a text message The syntax of the commands to send are TERMO HEATING TERMO COOLING For example TERMO HEATING sets the heating operating mode Th...

Страница 29: ...nt to 18 C The phone number in the phonebook that sends the command will receive a text message confirmation For example TSET 18 0 C SUMMER Definition of the night reduction mode It is possible to def...

Страница 30: ...ring the daily time slot there is no night reduction mode ON flashing during the night time slot night reduction mode Request information It is possible to query the thermostat to receive information...

Страница 31: ...ackout external alarm in case of generic alarm on the digital input For each alarm source it is possible to specify phone numbers in the phonebook to send the text message The instrument is configured...

Страница 32: ...ALARM 1 3 4 Note a new setting of receivers overwrites the previous setting therefore it is necessary to indicate all receivers in a single command To delete a setting of the receivers use EMPTY For e...

Страница 33: ...cluded For example TEXT ALARM EXTERNAL boiler shutdown alarm in this case if an alarm occurs on the input the text boiler shutdown alarm will be sent to the specified phone numbers Definition of the a...

Страница 34: ...by the external probe exceeds 28 5 C for 50 minutes and considers the alarm restored when the temperature decreases 27 C 28 5 1 5 Note the return alarm is immediate when the return alarm of the temper...

Страница 35: ...es are not redirected Password management All commands previously described can also be sent by phone numbers not stored in the phonebook as long as the message starts with the correct password The de...

Страница 36: ...f message TERMO NUMBER 3331234567 Manually If the number of the SIM card in the Thermo GSM is not specified it is possible to synchronise time and date remotely Once the power supply restoration messa...

Страница 37: ...front panel and can be replaced without disconnecting the power supply voltage Use batteries NiMh AA with a capacity of 2000 mAh or higher Do not use non rechargeable batteries for any reason In case...

Страница 38: ......

Страница 39: ......

Страница 40: ...V3ISO0799 011 Vemer S p A I 32032 Feltre BL Via Camp Lonc 16 Tel 39 0439 80638 Fax 39 0439 80619 e mail info vemer it web site www vemer it...

Отзывы: