HP10E / HP12E / HP15E / HP20E - Dairy design
6. Graphical control
6-68
© VEMAG 2013
Number
Message
Cause
Remedy
607
Target position timeout
The main drive has reached the
target position but the „in position“
signal has not been sent.
Update is needed for the main
drive parameter set. Inform VE-
MAG Customer Service.
608
Portion time exceeded
Calculated portion time exceeded. This may be an indication that
product is too cold or too dense.
609
Input channel already in
use!
The selected analog/digital input
is already being used by a differ-
ent function.
If desired, switch to a different
input channel.
610
Jumper S-L is missing in
remote connector!
The S-L jumper is expected in the
remote control connector in the
current modes.
Switch mode or plug in the rel-
evant remote control connector.
611
Jumper E-F is missing in
remote connector!
The E-F jumper is expected in the
remote control connector in the
current modes.
Switch mode or plug in the rel-
evant remote control connector.
612
Jumper E-F is misplaced
in remote connector!
The E-F jumper is not required in
the remote control connector in the
current modes.
Switch mode or plug in the rel-
evant remote control connector.
613
Sensor for chain position
The sensor for LPG belt position
is not providing a signal to S-K.
Check the sensor for belt position
in the LPG.
614
A-C signal interrupted!
The A-C signal was interrupted
in the wrong operating state
(e.g. because LPG safety cover
was opened).
Do not open safety cover during
operation. Otherwise check con-
nector contacts for corrosion.
615
Sensor for chain position
The sensor for LPG belt position
is not providing a signal to S-K
despite belt starting.
Check the sensor for belt position
in the LPG.
616
Synchronous signal miss-
ing!
The synchronization signal (S-K)
failed during production.
Was the line stopped? Check
signal (S-K).
621
Lubrication complete
The lubrication system runs every
10 hours for the set number of
seconds while the infeed unit is
running. The message indicates
that the lubrication process is
complete.
--
622
Remote-K exceeds speed
limit
The Remote-K signal displays the
speed if „Portions per signal“ is
active. The message indicates that
the „Speed limit“ parameter has
been exceeded.
Check that the signal to Remote-
K and the „Speed limit“ setting
match.
624
Limit exceeded
„Print mark control“ exceeded
permissible weight.
„Print mark control“ is a complex
application that must be checked
by an experienced technician. Un-
der certain circumstances, you will
have to accept heavier weights.
625
Restart during back
suction
The start command came before
the back suction process ended.
Check the process: Increasing the
back suction does not make sense
if the next start is scheduled too
soon.
627
Jumper A–G is missing in
remote control connector!
(+ operating mode is not
correct for attachment)
This operating mode requires
jumper A-G in the remote control
connector.
Change the operating mode or
insert the corresponding remote
control cable.
Содержание HP10E
Страница 8: ......
Страница 10: ...HP10E HP12E HP15E HP20E Dairy design 0 Foreword 0 2 VEMAG 2013...
Страница 26: ...HP10E HP12E HP15E HP20E Dairy design 3 Installation and commissioning 3 6 VEMAG 2013...
Страница 34: ...HP10E HP12E HP15E HP20E Dairy design 4 Setting up 4 8 VEMAG 2013...
Страница 38: ...HP10E HP12E HP15E HP20E Dairy design 5 Operation 5 4 VEMAG 2013...
Страница 40: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 2 VEMAG 2013 Colour screen Keypad Function keys...
Страница 52: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 14 VEMAG 2013 Mode group Mode View...
Страница 56: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 18 VEMAG 2013...
Страница 58: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 20 VEMAG 2013...
Страница 60: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 22 VEMAG 2013...
Страница 97: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 59 VEMAG 2013...
Страница 100: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 62 VEMAG 2013...
Страница 157: ...HP10E HP12E HP15E HP20E Dairy design 10 Appendix 10 3 VEMAG 2013 10 3 Dimensional drawings HP10E HP12E HP15E HP20E...