HP10E / HP12E / HP15E / HP20E - Dairy design
6. Graphical control
6-65
© VEMAG 2013
Number
Message
Cause
Remedy
364
IO module A6
IO module A6 is not present or not
functioning properly.
Check that module A6 is firmly
seated; replace the module if
necessary.
365
Lubrication filling level
The lubrication filling level is too
low.
Check the lubrication filling level.
366
Hoist not available
There is a button signal for the
hoist even though a hoist has not
been set up.
Set up the hoist at service screen
2, if available. Check the wiring
and connection (terminal).
367
Hopper level = automati-
cally blocks hoist
If „Automatic“ is selected for the
„hopper level“ option, the hoist
buttons are inactive.
Select another mode for the hop-
per level if you want to activate the
hoist.
368
Hopper vacuum
Vacuum hopper 149: the vacuum
in the hopper prevents the cover
from opening.
Select „Off“ for hopper mode.
400
Filling pressure too high!
Filling pressure control has
stopped the machine.
In the case of grinding applications,
this may indicate blocked hole plates;
clean the hole plate if necessary.
401
Hopper empty?
The hopper level sensor has
detected that the level has fallen
below the minimum value.
Pour product into the hopper.
402
System being filled!
At the start of pressure control,
the pipe system is filled slowly.
-
403
Product temperature
Product temperature outside set
range.
Reduce or increase product tem-
perature.
404
Tighten up union nut!
Pressure monitoring: This hint ap-
pears after the pipe system is filled.
-
406
Stops due to product
temperature
A preset product volume was filled
in excess of the permitted tempe-
rature range.
Make sure that the product in the
hopper is at the right temperature.
Check the setup.
407
Minimum pressure not
achieved
(+ hopper empty?)
The machine could not attain 0.6
bar in the first 15 seconds.
Check the sensor (fu po-
sition), fill the hopper, start it again
until the pipe is filled or deactivate
„Max. filling pressure“ if the sensor
is not needed.
408
Fallen below the minimum
pressure
(+ hopper empty?)
The pressure drops below 0.6 bar
for more than 5 seconds.
Check the sensor (fu posi-
tion), fill the hopper or deactivate
the „Max. filling pressure“ if the
sensor is not needed.
409
Max. speed timeout
(+ hopper empty?)
The machine could not attain the
pressure at full speed.
Check the sensor (fu posi-
tion) and fill the hopper.
410
Fallen below the minimum
vacuum
(+ hopper empty?)
The vacuum sensor has deter-
mined that the vacuum is below
the minimum.
Fill the hopper and check the
sensor.
420
More samples!
Scale 877 The operator is requested
to put another sample on the scale.
-
421
Result printing!
Scale 877 The scale report
is printing.
-
Содержание HP10E
Страница 8: ......
Страница 10: ...HP10E HP12E HP15E HP20E Dairy design 0 Foreword 0 2 VEMAG 2013...
Страница 26: ...HP10E HP12E HP15E HP20E Dairy design 3 Installation and commissioning 3 6 VEMAG 2013...
Страница 34: ...HP10E HP12E HP15E HP20E Dairy design 4 Setting up 4 8 VEMAG 2013...
Страница 38: ...HP10E HP12E HP15E HP20E Dairy design 5 Operation 5 4 VEMAG 2013...
Страница 40: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 2 VEMAG 2013 Colour screen Keypad Function keys...
Страница 52: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 14 VEMAG 2013 Mode group Mode View...
Страница 56: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 18 VEMAG 2013...
Страница 58: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 20 VEMAG 2013...
Страница 60: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 22 VEMAG 2013...
Страница 97: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 59 VEMAG 2013...
Страница 100: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 62 VEMAG 2013...
Страница 157: ...HP10E HP12E HP15E HP20E Dairy design 10 Appendix 10 3 VEMAG 2013 10 3 Dimensional drawings HP10E HP12E HP15E HP20E...