Set-up of KLI 110 to operate products connected to control unit
KLC 500
1
Disconnect control unit KLC 500 from power outlet and remove
cover. Temporarily disconnect product cables for products
not
to be
operated by this control keypad KLI 110.
2
Reconnect control unit KLC 500 to power outlet and press test but-
ton for 1 second.
Caution:
Press test button for 10 seconds if you want to delete
all
previous set-ups.
3
When one of the products runs briefly back and forth, press button
R
on control keypad KLI 110 for 1 second.
Note:
Steps 2-3 must be completed within 10 minutes.
4
Disconnect control unit KLC 500 from power outlet, reconnect all
disconnected cables and replace cover. Reconnect control unit
KLC 500 to power outlet.
Repeat steps 1-4 for each additional control keypad KLI 110.
The products can now be operated by KLI 110.