10
2 Loading or source exchange
Source loading and exchange • VEGASOURCE 31, 35
39155-EN-181126
•
Unscrew the capstan screw (5) with a flat headed screwdriver, size
1.5 x 10
•
Insert the holding pin (5) and move with the stirrup over the pin
•
Bring the stirrup to the extraction position
Fig. 7: VEGASOURCE - version B in extraction position
•
If necessary, screw an extension rod (11) with thread M8 into
the socket of the source holder (10). With this extension you can
increase the distance to the source
•
Pull out the source holder (10)
•
If it is present, remove the safety bolt (7), Allen key size 2.5
•
Swivel the cover (8) in front on the thin cylinder of the source
holder (10) to the side. To do this, lift the cover (8) slightly with a
small slotted screwdriver
•
Only when exchanging the source: Allow the source capsule (9) to
fall out downwards into a shielded vessel
•
Insert new source capsule (9) and close cover (8). For insertion
use a suitable gripping device or a manipulator
•
Screw in the safety bolt (7) (optional)
•
Completely insert the source holder (10) into the source container
and turn it until the holding pin (5) pops out
•
If necessary, remove extension rod (11)
•
Continue turning the source holder (10) up to position OFF
•
Fit the padlock (1) and lock
•
Let the fixing pin (3) snap in
•
Tighten locking screw (2)
•
Screw in capstan screw (6) and secure together with the retaining
pin (5) with new seal
•
Attach safety catch (4)
•
Remove existing type labels (when exchanging the source)
•
Unpack the type label set and letter it respectively. You can find
further information in chapter "
Safety instructions - Labelling
"
Insert or exchange
source
Insert source holder
Attach or replace the type
labels