45
6 Set up with the display and adjustment module
VEGAFLEX 81 • Profibus PA
44214-EN-171002
The instrument settings are copied with this function. The following
functions are available:
•
Read from sensor: Read data from sensor and save in the display
and adjustment module
•
Write to sensor: Save data from the display and adjustment mod
-
ule back into the sensor
The following data or settings for adjustment of the display and ad
-
justment module are saved:
•
All data of the menu "
Setup
" and "
Display
"
•
In the menu "
Additional adjustments
" the items "
Reset, Date/Time
"
•
Special parameters
The copied data are permanently saved in an EEPROM memory in
the display and adjustment module and remain there even in case of
power failure. From there, they can be written into one or more sen
-
sors or kept as backup for a possible electronics exchange.
Note:
Before the data are stored in the sensor, a check is carried out to
determine if the data fit the sensor. If the data do not fit, a fault signal
is triggered or the function is blocked. When data are being written
into the sensor, the display shows which instrument type the data
originate from and which TAG-no. this sensor had.
Tip:
We recommend to save the instrument adjustments. In case of an
electronics exchange the saved parameter adjustment data relieve
this process.
In this menu item you can select the type and size of your probe from
a list of all possible probes. This is necessary to adapt the electronics
optimally to the probe.
In this menu item you gain access to the protected area where
you can enter special parameters. In exceptional cases, individual
parameters can be modified in order to adapt the sensor to special
requirements.
Change the settings of the special parameters only after having con
-
tacted our service staff.
Additional settings - Copy
instrument settings
Additional settings -
Probe type
Additional settings - Spe-
cial parameters