Instruction Manual
VLB-67 LED Beacon
© Vega Industries Ltd, July 2014
VLB-67 LED Beacon
Page 35 of 52
VLB-67 V1.0.17
APPENDIX D
VLB-67 SETTINGS
Complete the table for the required settings required. It is only necessary to program the specific
settings where they are different to the settings already programmed.
The programming can be done sequentially without leaving the program mode. After the light has
flashed back the setting enter the next setting within 10 seconds or the light will exit the
programming mode.
To read the settings already programmed
Setting
Key sequence
Value
Flash Character
90
Night Effective Intensity
91
Day Effective Intensity
92
Synchronisation
93
Day/Night Control
94
Operation mode
95
Programming mode
96
Slave Mode Flash count on loss of sync
97
Battery Low Threshold
98
Battery High Threshold
99
To enter new settings
Setting
Default
Settings required
Flash Character
QFL 1sec (0.3s on) 1-0-601
10_______
Night Effective Intensity
25 Candela
1-1-0025
11_______
Day Effective Intensity
25 Candela
1-2-0025
12_______
Synchronisation
Master, no delay
1_3_000
13_______
Day/Night Control
Night, IALA setting
1_4_005
14_______
Operation mode
Normal
1_5_000
15_______
Programming mode
Data Ports off
1_6_000
16_______
Slave Mode Flash count
on loss of sync
1 Character cycle
1_7_001
17_______
Battery Low Threshold
11.0 Volts
1_8_110
18________
Battery High Threshold
12.8 Volts
1_9_128
19________