Instruction Manual
VLB-67 LED Beacon
© Vega Industries Ltd, July 2014
VLB-67 LED Beacon
Page 27 of 52
VLB-67 V1.0.17
APPENDIX A
PROGRAMMING TABLE
Operation
Feature
Value
1 = Program Mode
9 = Read Settings
0 = Flash Character
Default 601
QFL 1sec (0.3 on)
000
–
Fixed character
1YY
–
Isophase (ISO)
2YY
–
Occulting (OC)
3YY
–
Flash (Fl)
4YY - Multiple Flash (Fl(x))
5YY - Very Quick (VQ)
6YY - Quick (Q)
7YY
–
Long (LF)
8YY
–
Morse (MO)
9YY
–
Custom (CCG Codes)
1 = Night Effective Intensity
Default 0025
25 candela effective
Four Digit Value
–
Enter value as a number 0000 to
9999.
0000 Sets minimum allowed value.
9999 sets maximum allowed value.
2 = Day Effective Intensity
Default 0025
25 candela effective
Four Digit Value
–
Enter value as a number 0000 to
9999.
0000 Sets minimum allowed value.
9999 sets maximum allowed value.
3 = Synchronisation
Default 000
Master sync no delay
999
–
Disable Synchronisation
998
–
Beacon activated by holding sync low.
Synchronization not possible since sync line used.
0YY Light in normal mode
1YY Light operates only when sync pulse present
YY=sync delay seconds (0.0 to 9.9 seconds )
4 = Day/Night Control
Default 005
Night operation
IALA recommended transition
0YY Light operates night only
1YY Light operates day and night
YY= Day/Night transition Lux Level
Night Lux. Day Lux
YY=01 40 100 shortest night
YY=02 50 150
YY=03 75 100 CCG
YY=04 75 150
YY=05 75 175 IALA suggested
YY=06 100 175
YY=07 100 200
YY=08 150 250
YY=09 250 320 longest night USCG
YY=10 15 40 shortest night
YY=11 30 50
YY=12 15 60