Instruction Manual
VLB-67 LED Beacon
© Vega Industries Ltd, July 2014
VLB-67 LED Beacon
Page 43 of 52
VLB-67 V1.0.17
LDI
Current = LDI * 0. 64453 milliamps
LOI
Current = LOI * 0. 64453 milliamps
CUR
Internal diagnostic variable
GUD
1
–
Beacon is Good ( no alarm )
DAY
1
–
Day is indicated
Example Data:
<BAT>424/<LIT>0/<TMP>376/<SLR>0/<BCI>-
1299/<SLI>0/<LDI>437/<LOI>437/<CUR>500/<GUD>1/<DAY>0/<END>/
<BAT>425/<LIT>0/<TMP>376/<SLR>0/<BCI>-
1323/<SLI>0/<LDI>433/<LOI>433/<CUR>500/<GUD>1/<DAY>0//<END>/
APPENDIX H
VLB-67 BEACON DIMENSIONS
Standard Self Contained Beacon
Standalone Beacon