Instruction Manual
VLB-67 LED Beacon
© Vega Industries Ltd, July 2014
VLB-67 LED Beacon
Page 28 of 52
VLB-67 V1.0.17
Operation
Feature
Value
1 = Program Mode
9 = Read Settings
5 = Operation Mode
Default 000
Normal
Note:
Self Contained units are shipped
from the Factory in Storage
Mode 009
000
–
Normal, also cancel Auto Storage/ Auto Leave
Storage mode.
007
–
Test Alarm signal output (Alarm operates until
beacon leaves programming mode).
009
–
Storage Mode, also cancel Auto Storage/ Auto
Leave Storage mode.
999
–
Reset beacon to Factory Default
–
All
changes will be lost. Auto Storage/Leave Storage
cancelled.
1N9
–
Auto Leave Storage on day light and place
beacon in storage mode. N is proportional to minutes
of light required to leave storage mode and reactivate
(see table below). Beacon must be placed in dark for
at least 1 minute to activate the Auto Leave function.
2N0
–
Auto Storage Mode on dark/Auto Leave
Storage on day. 24 hours of darkness will force
beacon into storage mode. N is proportional to
minutes of light that will cause beacon to leave
storage mode and reactivate (see table below).
2N9
–
Same as 2N0 except beacon is immediately
placed in storage mode upon exit from programming.
Where N is 0-9
N = 0 ~2 minutes of light releases beacon from
storage
N = 1
~12 minutes of light releases beacon
from storage
N = 2
~22 minutes of light releases beacon
from storage
…
N = 9 ~92 minutes of light releases beacon
from storage
Read Settings are a combination of the activated
modes:
119: Auto Leave Storage 12 minutes, Storage Mode
on exit.
220: Auto Storage Mode activated, 22 minute leave
storage, Normal Operation on exit.
009: Storage Mode Only
000: Normal mode only
149: Auto Leave 41 minute, and Storage Mode on
exit.
209: Auto Storage, Auto Leave 1 minute and Storage
Mode on exit.