Instruction Manual
VLB-67 LED Beacon
© Vega Industries Ltd, July 2014
VLB-67 LED Beacon
Page 18 of 52
VLB-67 V1.0.17
The programming sequence to enter this flash character is 10602
0. Enter programming mode
Press the red standby button
for 5 seconds
The light will give 4 quick flashes to indicate it has entered programming
mode
If the VLB-67 has been programmed for Calendar or auto storage mode the
flash response will be different.
2. Enter the programming
sequence for the flash character
(10602)
The light will flash once each time a key on the programmer is operated.
When the sequence is completed and accepted the light will repeat the value
602 in a series of flashes. Six quick flashes followed by a 0.5sec gap
followed by a 2 second flash (for a zero) followed by a 0.5 second gap
followed by two quick flashes
1. Exit programming mode
Leave the programmer idle for
10 seconds
The light will give two quick flashes followed by a short pause followed by
another two quick flashes.
If the VLB-67 has been programmed for Calendar or auto storage mode the
flash response will be different.
After this it will resume normal operation. The light will flash its character for
16 seconds while it checks the day/night settings. If it is daytime and the
light is set to operate at night only the light will turn off.
Create a programming error by attempting to enter an invalid Operation Mode code 003
Determine the programming Syntax from Appendix A for the setting:
Operation
=Programming
=1
Feature
=Operation Mode
=5
Value
=Code
=003
The programming sequence to enter this Operation Mode is 15003
x
Enter programming mode
Press the red standby button for 5 seconds
The light will give 4 quick flashes to indicate it has
entered programming mode
If the VLB-67 has been programmed for Calendar or auto
storage mode the flash response will be different.
x
Enter the programming sequence for the
Operation Mode (15003)
The light will flash once each time a key on the
programmer is operated.
When the sequence is completed the value will be
rejected and an error indicated by 3 quick flashes.
The beacon will then return to programming mode and is
ready for a new instruction.
x
Exit programming mode
Leave the programmer idle for 10 seconds
The light will give two quick flashes followed by a short
pause followed by another two quick flashes.
If the VLB-67 has been programmed for Calendar or auto
storage mode the flash response will be different.
After this it will resume normal operation. The light will
flash its character for 16 to 20 seconds while it checks
the day/night settings. If it is daytime and the light is set
to operate at night only the light will turn off.