3.2 Front Panel Buttons
Power:
Press for 2 seconds to turn the test set ON or
OFF (prevents accidental ON/OFF) If a test is running
when the power off is started, test is terminated and
results may not be automatically saved
Save Test Results:
Saves the current Test Results with
customized or auto naming (Auto uses the yyyymmdd-
hhmmss name format)
Lock/Unlock Touch Screen or Screen Capture:
Can
also be programmed to Capture Screen shots Go to
>Utilities >Settings >Global >Save Settings to set Save
Screen and image compression option
Volume and Brightness Control:
(it also acts as the
MTT F1 key, when the is active) Brings up the Sound
and screen Brightness controls Use cursor buttons to
adjust the levels
Clear History:
Resets blinking LED reminders of past
Errors or Alarms Test results are not affected
Camera App:
Launches the optional Camera App to
help document the job site, damage, connections, etc.
Requires the camera (factory-installed option)
3.3 Hardware Configurations