Mag-FLEX Probe Overview

Mag-FLEX Probes Part Number Specification

8

Mag-FLEX Probes Part Number Specification

Table 3 and Table 4 contain part numbers for ATEX version Mag-FLEX probes. 

Table 3.  ATEX Version - For TLS4/4B pre-Version 6A or TLS-450 pre-Version 4M or TLS-3xx & TLS 2 / 2P All Versions

Part Numbers* – ATEX Version

English - Feet

Metric - mm

88956Y-1XX (Petroleum up to E10)
88956Y-2XX (Diesel)
88956Y-3XX (No Water Detect)
(Where Y = 0 or 1 depending on factory 

build date; and XX = numbers selected 

in the column below)

Min. 

length

Max. 

Length

Min. 

length

Max. 

Length

00

6.56

2000

01

6.59

9.84

2010

3000

02

9.88

13.12

3010

4000

03

13.16

16.40

4010

5000

04

16.44

19.69

5010

6000

05

19.72

22.97

6010

7000

06

23.00

26.25

7010

8000

07

26.28

29.53

8010

9000

08

29.56

32.81

9010

10000

09

32.84

36.09

10010

11000

10

36.12

39.37

11010

12000

11

39.40

42.65

12010

13000

12

42.68

45.93

13010

14000

13

45.96

49.21

14010

15000

14

49.25

52.50

15010

16000

15

52.52

55.77

16010

17000

16

55.81

59.06

17010

18000

17

59.08

62.33

18010

19000

18

62.36

65.61

19010

20000

19

65.64

68.89

20010

21000

20

68.93

72.18

21010

22000

*For example, to order a Mag-FLEX Probe for Diesel, min./max. length 42.68 – 45.93 feet 

(in green), order P/N 889561-212.

Содержание Mag-FLEX

Страница 1: ...Manual No 577014 038 Revision C Installation Manual EU Version Mag FLEX Probe...

Страница 2: ...eder Root reserves the right to change system options or features or the information contained in this publication This publication contains proprietary information which is protected by copyright All...

Страница 3: ...sp Demounting 10 Information On Safe Installation 10 Information On Safe Adjustment 11 Information On Safe Putting Into Service 11 Information On Safe Maintenance And Repairing 11 Mag FLEX Probe Lengt...

Страница 4: ...sions 21 Figure 5 Splice Connections 22 Figure 6 Removing Sealing Compound Clip 23 Figure 7 Pouring Sealing Compound Into Sleeve 23 Tables Table 1 Temperature Class Ta Tf 3 Table 2 Dimensions for Mag...

Страница 5: ...nstallation checkout startup programming and operations training system tests troubleshooting and servicing for all Veeder Root Series Tank Monitoring Systems including Line Leak Detection TLS 3xx Tec...

Страница 6: ...sical injury WARNING indicates a hazardous situa tion which if not avoided could result in death or serious injury CAUTION indicates a hazardous situation which if not avoided could result in minor or...

Страница 7: ...use in a TLS Monitoring System Except for the cables used to connect intrinsically safe apparatus information contained on the system certificate and each of the device certificates provide the safety...

Страница 8: ...taken when determining the suitability of the installation conditions and operation of the TLS Monitoring System The Mag FLEX probe is provided with a standard process connection suitable for the bou...

Страница 9: ...g complies with the 500 volt electrical strength requirements in IEC EN 60079 11 In addition the probe housing should be equipotentially bonded to the tank structure via a 4mm2 wire not provided and t...

Страница 10: ...he base of the probe to give stability suitable for use in a wide range of products and available with or without water detection The Mag FLEX Probe with standard water float uses a process connection...

Страница 11: ...t stainless steel 316L Encapsulation of retaining magnet conductive plastic PTFE with graphite Ex approvals T V 12 ATEX 105828 IECEx TUN 12 0027 Operating temperature range 20 C to 60 C when fully ins...

Страница 12: ...mn below Min length Max Length Min length Max Length 00 6 56 2000 01 6 59 9 84 2010 3000 02 9 88 13 12 3010 4000 03 13 16 16 40 4010 5000 04 16 44 19 69 5010 6000 05 19 72 22 97 6010 7000 06 23 00 26...

Страница 13: ...2010 3000 02 9 88 13 12 3010 4000 03 13 16 16 40 4010 5000 04 16 44 19 69 5010 6000 05 19 72 22 97 6010 7000 06 23 00 26 25 7010 8000 07 26 28 29 53 8010 9000 08 29 56 32 81 9010 10000 09 32 84 36 09...

Страница 14: ...oups IIA IIB and IIC and its temperature class is T6 The overvoltage protection is enclosed by a metal enclosure The material composition of the enclosure includes according to EN IEC 60079 0 clause 8...

Страница 15: ...g INFORMATION ON SAFE MAINTENANCE AND REPAIRING In general the equipment is maintenance free Defective equipment must be returned to the manufacturer or one it s representatives If a test is required...

Страница 16: ...nt to the bottom of the tank see diagram below Probe length for ordering purposes A 250 mm Probe Handling It is important to handle the Mag FLEX probe with care at all times during the installation Av...

Страница 17: ...approval for this system and is not permitted Combining cables from different systems may also result in improper system operation Unless specified otherwise any draw pits should be sited at 10 metre...

Страница 18: ...k entry point provided must have an internal thread of 1 BSP or 4 BSP when installing a low level water float PROBE ASSEMBLY The process connection water float product float weight and magnet are ship...

Страница 19: ...obe from its packaging to prevent any kinking or distortion of the flexible probe shaft Damage caused by mishan dling will not be covered under warranty If there is deformation at the transition point...

Страница 20: ...ing the probe into the tank The coil should be held as shown maintain ing the coiled shape to prevent kinking With the 5mm hex key loosen the socket cap screw and gland Slide the process connection to...

Страница 21: ...m the lower edge of the probe canister to the top of the tank entry point installation dimension record this measurement Unroll the corrugated shaft as the probe is lowered into the tank taking care t...

Страница 22: ...r Raise the probe canister until the exact installation dimension that you measured recorded in step 8 is achieved Attention Do not raise the probe any higher as it will become detached from the botto...

Страница 23: ...field wiring to ATG Conduit 038 1 4mm2 0 ground wire from Surge Protector to tank ground 4mm2 0 ground wire from Probe canister to tank ground Example Wireless Installation Example Hardwired Installat...

Страница 24: ...onnector of the supplied Leader Cable to the M12 connector on the probe head First tighten the union nut of the M12 connector by hand and then tighten the nut a further 180 using an open ended spanner...

Страница 25: ...h Dimensions An 10 gauge 4mm eearth cable must be connected between the surge protector and tank ground connection According to the provision of EN IEC 60079 14 the minimum size of the earth cable sha...

Страница 26: ...tion May be irritating to the eyes Avoid skin and eye contact Avoid repeated and prolonged breathing of vapor Use only in well ventilated areas Wear chemically resistant gloves Inhalation provide fres...

Страница 27: ...e entire sleeve Do not overfill Figure 7 Figure 7 Pouring Sealing Compound Into Sleeve 7 With a twisting motion rotate the outer clear plastic barrel to close the pouring slot Wait at least five minut...

Страница 28: ...3 See manual 577014 056 for setup instructions when installing a low level water float Tank Profile Select Linear for TLS2 TLS 3XX or TLS 450 consoles or Multi Point if an accurate tank chart is avail...

Страница 29: ...Refer to the site preparation procedures in this manual for general instructions on safe installation use and replacement The above values are to be used when assembling a system in the field when for...

Страница 30: ...e 1 Zone 0 is given only under atmospheric conditions Temperature range 20 C 60 C Pressure range 0 8 bar 1 1 bar Oxidants Air oxygen content of about 21 Specific Conditions of Use None Category 2 and...

Страница 31: ......

Отзывы: