background image

 

TCY-FT 

Technical specifications 

 

Doc: 70-00-0129B, V1.2, 2012-11-09 

© Vector Controls GmbH, Switzerland 

Page 2 

Subject to alteration 

www.vectorcontrols.com 

Technical specifications 

Power Supply 

Operating Voltage 

24 V AC ± 10 %, 50…60 Hz, Class 2, 48VA max 

Power Consumption 

Max. 1.5 VA 

Electrical Connection 

Terminal Connectors,  
wire 0.34…2.5 mm

2

 (AWG 24…12)

 

Signal inputs 

Temperature Input 
Range 

Accuracy 

 
0…50 °C (32…122 °F) 

0.5 K 

Signal outputs 

TRIAC Outputs  
Switching power 

 
24 VAC, 250mA max 
Do not use actuators with power consumption > 6VA 

Environment 

Operation 

Climatic Conditions 

Temperature 

Humidity 

To IEC 721-3-3 

class 3 K5 

0…50 °C (32…122 °F) 

<95 % r.H. non-condensing 

Transport & Storage 

Climatic Conditions 

Temperature 

Humidity 

Mechanical Conditions 

To IEC 721-3-2 and IEC 721-3-1 

class 3 K3 and class 1 K3 

-25…70 °C (-13…158 °F) 

<95 % r.H. non-condensing 

class 2MT2 

Standards 

conform according to  

EMC Standard 89/336/EEC 

EMEI Standard 73/23/EEC 

 

EN 61 000-6-1/ EN 61 000-6-3 

Product standards 

Automatic electrical controls for 

household and similar use 

Special requirement on temperature 

dependent controls 

 

EN 60 730 –1 

 

EN 60 730 – 2 – 9 

Degree of Protection 

IP30 to EN 60529 

Safety Class 

III (IEC 60536) 

Cover, back part 

Mounting Plate 

Fire proof ABS plastic (UL94 class V-0) 

Galvanized Steel 

General 

Dimensions (H x W x D) 

Front part: 88 x 88 x 21 mm (3.5” x 3.5” x 0.8”)  
Power case: ø 58 x 32 mm (ø 2.3” x 1.3”) 

 

Weight (including package) 

250 g (8.8 oz) 

Dimensions [mm] (inch) 

88 (3.5) 

32 (1.2) 

21  

(0.8) 

88

 (

3.

5)

 

58

 (

2.

3)

 

Содержание TCY-FT Series

Страница 1: ...l tool or software is required Name Ordering Item Name Item code Control Type Key data TCY FT2 W01 40 10 0067 1 Cooling only Compact PI controller with 2 TI 1 3 point output TCY FT2 W02 40 10 0067 2 H...

Страница 2: ...F 95 r H non condensing Transport Storage Climatic Conditions Temperature Humidity Mechanical Conditions To IEC 721 3 2 and IEC 721 3 1 class 3 K3 and class 1 K3 25 70 C 13 158 F 95 r H non condensing...

Страница 3: ...4 5 above the floor in an area of average temperature Avoid exposure to direct sunlight or other heat sources e g the area above radiators and heat emitting electrical equipment Avoid locations behind...

Страница 4: ...e connected to a power supply for at least 10 hours for the backup function to operate accordingly Error messages The TCY FT may display the following error condition Err1 The connection to the temper...

Страница 5: ...t a password using UP or DOWN buttons Select 009 in order to get access to the user parameters 241 for controls parameters Press OPTION after selecting the correct password 3 Once logged in the parame...

Страница 6: ...FT2 W1 Cooling mode YC1 1 TCY FT2 W2 Heating mode YH1 2 TCY FT2 Heating and Cooling 2 pipe system YH1 YC1 3 TCY FT4 Heating and Cooling 4 pipe system YH1 YC1 TCY FT2 0 2 TCY FT4 0 3 TCY FT2 W1 0 TCY...

Страница 7: ...sed to fully open 0 255s 90s CP 14 Minimum running time FO1 TCY FT4 heating output The minimum time the output runs once it starts This setting prevents frequent switches with very short running times...

Страница 8: ...ion detectors for offices CP18 2 Switching Energy Hold OFF and Comfort modes Opening the external temperature input will force the unit into the OFF operation mode The operation mode cannot be overrid...

Отзывы: