The image above shows a poor glue line with glue build-up on the nozzle at the point
where the edge material leaves the nozzle.
This is caused by insufficient glue pressure at the cartridge and is usually due to the
cartridge not being free to move in the teflon infeed guide (73) of the cartridge heater.
It can also be caused by inferior quality glue which may have variable viscosity
characteristics or excess filler.
Ensure high quality glue (of known quality) is used and allow longer after start up for the
heat to normalise through the entire gluing system. This will usually free the glue cartridge
after 10 minutes or so.
If this does not correct the issue, it is possible to manually purge the nozzle. This process
applies pressure to the cartridge with the dosing bar open which when combined with heat
and time, will cause the cartridge to free up and start flowing.