9.3.4 Advanced Controls: Feed
These settings are:
Start Speed
Feed speed when laying tape at commencement of cycle
Fast Speed
Maximum speed attained on straight edges
Hold count bump bar
Distance after bump bar is released before speed, bias and
roller pressure return to standard.
Bump bar speed
Feed speed when bump bar is touched (this will be overridden
by slower speeds such as corner speeds). This speed will be
retained until the Hold Count bump bar turns off after the bump
bar returns to position
Convex Speed
Speed around tight convex corners (as determined by the
convex sensor dropping off the panel). If the convex sensor
remains on the panel, such as in a big external radius, this
speed will not be used.
Convex Trim Speed
Second stage of convex corner to bring the trimmer around the
corner at other than Fast Speed
Concave Trim Speed
Second stage of concave corner to bring the trimmer around
the corner at slow speed to ensure quality of trimming. Note
concave banding speed is not operator adjustable.
Slow Delay Convex (ms) Timer after the convex sensor drops off the panel before the
speed slows. If set to zero, the section of band which will be
wrapped around the corner remains longer on the nozzle which
puts more heat into the band material.