background image

7

3.

USE AS A 12 VOLT DC PORTABLE POWER SUPPLY

WARNING:

 NEVER INSERT A CIGARETTE LIGHTER IN POWER CITY’S ACCESSORY SOCKET.

1. Lift up the cover of one of the12 volt DC Accessory Sockets.

2. Insert the 12 VOLT DC plug from the appliance into the Accessory Socket.

3. Switch on the appliance, as usual.

4. Periodically press the Battery Status Pushbutton to check battery status.

5. When the Charge Status goes to one red LED, recharge the Main Unit battery.

CAUTION:

 DO NOT USE POWER CITY TO OPERATE DC APPLIANCES THAT DRAW MORE

THAN 23 AMPS.

4.

POWER INVERTER

The Power Inverter is an electronic device that converts low voltage DC (direct current) from the

battery or other power source to standard 110 volt 60 Hz AC (alternating current) household

power. Safety features include an audible low battery alarm and automatic shutdown to

prevent damage to your Power City internal battery. See Figure 4.

FIGURE 4

4.1

INVERTER OPERATION

Removing the cover that protects the AC receptacle on the inverter can access the inverter.
NOTE:

 On this end of the inverter are: the AC receptacle, the On/Off Switch, a green LED and

a red LED. The green LED, when lit, indicates power is applied to the inverter and it is

operating properly. The red LED, when lit, indicates that something caused the inverter to

shut down. The green LED will not be lit under shutdown conditions. Inverter shutdown is

caused by: under- or over-voltage, overheat or overload. If the inverter shuts down, first

check the Main Unit battery (use Battery Status Push-button and Display) to see if the main

battery is discharged, Recharge the battery as soon as possible. If another condition caused

the shutdown, investigate the appliance for excessive wattage or a connection between

neutral and ground (explained later). If the inverter feels very warm let it cool before

restarting it. Restart is accomplished by turning the Inverter Switch Off, then On.

Operation is simple:

• Remove Inverter's Receptacle Cover

• Plug the appliance's 110 volt plug into the Standard AC receptacle on the inverter.

• Turn On the inverter power switch.

• Turn On the appliance and operate it as usual.

• After use, turn off the power inverter's On/Off Switch
The Inverter can also be used away from the Main Unit by removing it from it's mounting on the

Main Unit and powering it from the Inverter Power Cable. Located in the Cable Storage

Compartment. See Figure 3.

1. INVERTER LOCK TABS

2. COVER TAB

3. RED SHUT DOWN LED

4. INVERTER ON/OFF SWITCH

5. 110 VOLT AC SOCKET

6. GREEN OPERATING LED

7. LIGHTED COMPRESSOR

GAUGE

6

1

2

7

3

4

5

Содержание Power City VEC029AC

Страница 1: ...ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN POSSIBLE INJURY OR PROPERTY DAMAGE 4140 SW 28TH WAY FT LAUDER...

Страница 2: ...puterized systems may be damaged if vehicle battery is jumpstarted Before jumpstarting this type of vehicle read the vehicle s owner s manual to confirm that external starting assistance is advised Ex...

Страница 3: ...verter fuse replacement 11 5 COMPRESSOR TIRE INFLATOR 11 5 1 Compressor Use 11 5 2 Warnings 11 5 3 Tire Inflation or products with a valve stem 12 5 4 Inflate other articles without valve stem 12 5 5...

Страница 4: ...terminals while preparing to jumpstart a dead battery in the dark changing a tire etc Power City is also ideal to power 12 volt DC cordless portable rechargeable appliances with ratings up to 23 ampe...

Страница 5: ...and power hand tools cellular phones camcorders power tool rechargeable batteries that have an appropriate recharging adapter with a 110 volt AC standard type plug Operate using 23 ampere rated 12 Vo...

Страница 6: ...clamp end of cable 8 Squeeze positive red clamp handles and slide clamp from holster 9 Connect positive red clamp to vehicle s positive battery terminal 10 Connect negative black clamp to chassis or a...

Страница 7: ...e inverter and it is operating properly The red LED when lit indicates that something caused the inverter to shut down The green LED will not be lit under shutdown conditions Inverter shutdown is caus...

Страница 8: ...11 and 14 5 volts DC and must be able to supply the necessary current amps to operate the load The power source may be a battery or a well regulated DC power supply To obtain a rough estimate of the...

Страница 9: ...sound it s alarm when DC voltage drops to 10 6 volts CAUTION Reverse polarity connection will result in damage to the inverter THIS WILL VOID THE WARRANTY If the inverter is connected to the incorrec...

Страница 10: ...iece of equipment that is generating heat above room temperature Keep the inverter away that from direct sunlight if at all possible VENTILATED Keep the area surrounding the inverter clear to ensure f...

Страница 11: ...ccessory socket 5 COMPRESSOR TIRE INFLATOR This built in 12 Volt DC compressor is the ultimate compressor for all Vehicles Trailer Tires and recreational inflatables Three different sized nozzles are...

Страница 12: ...very rapidly 5 Insert adaptor e g needle into item to be inflated and inflate to desired pressure 6 Turn ON compressor switch inflate to desired pressure or fullness refer to paragraph 5 5 7 Remove ad...

Страница 13: ...Main Unit using the Inverter Power Cable with attached Lantern Extension Cord This allows great flexibility in positioning the Lantern during tire infla tion and during under the hood inspections See...

Страница 14: ...BATTERY Lead acid batteries require maintenance to maintain a full charge and to ensure good battery life All lead acid batteries suffer from self discharge over time and more rapidly when they are a...

Страница 15: ...ed in their own Cable Storage Hatch in the Main Unit Recharging the Main Unit s internal battery from an external DC power source requires the use of the DC Recharge Cable and the Inverter Power Cable...

Страница 16: ...harging adapters cables etc contact Vector Technical Support 954 584 4446 or call toll free 866 584 5504 Except for a fuse in the inverter and a lamp in the Lantern there are no user serviceable parts...

Страница 17: ...ower Inverter Continuous 200 Watt 60 Hz 110 120 VAC Power Inverter Peak 300 Watt 60 Hz 110 120 VAC Inverter Waveform Modified Sine Wave Inverter DC Input Range 10 0 to 14 6 VDC Inverter Audible Alarm...

Страница 18: ...cratches abrasions repairs by unauthorized persons or failure to follow recommended care and use instructions Damage caused by misuse abuse neglect alterations repairs by unauthorized persons or failu...

Страница 19: ...instructions Damage caused by misuse abuse neglect alterations repairs by unauthorized persons or failure to follow recommended care and use instructions Bulbs and batteries Please activate my Extende...

Страница 20: ...20 2000 VECTOR MANUFACTURING Ltd FT LAUDERDALE FL 33312 MADE IN CHINA...

Отзывы: