background image

2

IMPORTANT SAFETY INSTRUCTIONS

Read and Understand all Warnings, Cautions and Notes before operating Power City.

Warnings alert the user to hazardous conditions that can be harmful to personnel. Cautions

alert the user to conditions that can cause property damage. Notes are important operational

information.

KEEP THIS USER’S GUIDE FOR FUTURE USE.

JUMPSTART WARNINGS AND CAUTIONS

• There is risk of explosive gas being released when batteries are Improperly charged or

discharged. Failure to follow instructions may Cause property damage, explosion

hazard and/or personal injury

• Do not smoke while jump starting

• Only attempt to jumpstart a vehicle or boat in a well ventilated Area

• This power system is to be used ONLY on vehicles or boats with 12 volt DC

battery systems

• Do not wear vinyl clothing when jumpstarting a vehicle - friction can cause dangerous

static electricity sparks

• Remove all metal jewelry - this can cause short circuits. Always use protective eyewear

when jumpstarting:  contact with battery acid may cause blindness and/or severe burns.

• Never touch Power City red and black clamps together - this can cause dangerous

sparks, power arcing and/or explosion

• Do not attempt to jumpstart a frozen battery

• After use as jumpstarter, turn off Safety Switch

• Keep out of reach of children.

• Vehicles that have on-board computerized systems may be damaged if vehicle batter y is

jumpstarted. Before jumpstarting this type of vehicle, read the vehicle's owner's manual

to confirm that external-starting assistance is advised

• Excessive engine cranking can damage the vehicle's starter motor. If the engine fails to

start after the recommended number of attempts, discontinue jumpstart procedure and

look for other problems that may need to be corrected

• When Safety Switch is OFF, Polarity Alarm is enabled. If Cables are connected to

another battery and the alarm sounds, the cable connections must be switched. If alarm

sounds, do not turn on Safety Switch.

• If vehicle to be started has a Positive Grounded System (positive battery terminal is

connected to chassis): Replace steps 9 and 10 of the jump start procedure (below) with

the following steps A and B, and then proceed to step 11

A. Connect negative (-) black clamp to vehicle battery 's negative terminal.

B. Connect positive (+) red clamp to vehicle chassis or a solid, non-moving, metal

vehicle component or body part. DO NOT clamp directly to positive battery

terminal or moving part.

• Replace worn or defective parts immediately - contact Vector Technical Support

Department at  (954) 584-4446.

• Skin: if battery acid comes in contact with skin, rinse immediately with water, then wash

thoroughly with soap and water. If redness, pain, or irritation occurs, seek immediate

medical attention.

• Eyes: if battery acid comes in contact with eyes, flush eyes immediately-for minimum of

15 minutes, seek immediate medical attention.

Содержание Power City VEC029AC

Страница 1: ...ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN POSSIBLE INJURY OR PROPERTY DAMAGE 4140 SW 28TH WAY FT LAUDER...

Страница 2: ...puterized systems may be damaged if vehicle battery is jumpstarted Before jumpstarting this type of vehicle read the vehicle s owner s manual to confirm that external starting assistance is advised Ex...

Страница 3: ...verter fuse replacement 11 5 COMPRESSOR TIRE INFLATOR 11 5 1 Compressor Use 11 5 2 Warnings 11 5 3 Tire Inflation or products with a valve stem 12 5 4 Inflate other articles without valve stem 12 5 5...

Страница 4: ...terminals while preparing to jumpstart a dead battery in the dark changing a tire etc Power City is also ideal to power 12 volt DC cordless portable rechargeable appliances with ratings up to 23 ampe...

Страница 5: ...and power hand tools cellular phones camcorders power tool rechargeable batteries that have an appropriate recharging adapter with a 110 volt AC standard type plug Operate using 23 ampere rated 12 Vo...

Страница 6: ...clamp end of cable 8 Squeeze positive red clamp handles and slide clamp from holster 9 Connect positive red clamp to vehicle s positive battery terminal 10 Connect negative black clamp to chassis or a...

Страница 7: ...e inverter and it is operating properly The red LED when lit indicates that something caused the inverter to shut down The green LED will not be lit under shutdown conditions Inverter shutdown is caus...

Страница 8: ...11 and 14 5 volts DC and must be able to supply the necessary current amps to operate the load The power source may be a battery or a well regulated DC power supply To obtain a rough estimate of the...

Страница 9: ...sound it s alarm when DC voltage drops to 10 6 volts CAUTION Reverse polarity connection will result in damage to the inverter THIS WILL VOID THE WARRANTY If the inverter is connected to the incorrec...

Страница 10: ...iece of equipment that is generating heat above room temperature Keep the inverter away that from direct sunlight if at all possible VENTILATED Keep the area surrounding the inverter clear to ensure f...

Страница 11: ...ccessory socket 5 COMPRESSOR TIRE INFLATOR This built in 12 Volt DC compressor is the ultimate compressor for all Vehicles Trailer Tires and recreational inflatables Three different sized nozzles are...

Страница 12: ...very rapidly 5 Insert adaptor e g needle into item to be inflated and inflate to desired pressure 6 Turn ON compressor switch inflate to desired pressure or fullness refer to paragraph 5 5 7 Remove ad...

Страница 13: ...Main Unit using the Inverter Power Cable with attached Lantern Extension Cord This allows great flexibility in positioning the Lantern during tire infla tion and during under the hood inspections See...

Страница 14: ...BATTERY Lead acid batteries require maintenance to maintain a full charge and to ensure good battery life All lead acid batteries suffer from self discharge over time and more rapidly when they are a...

Страница 15: ...ed in their own Cable Storage Hatch in the Main Unit Recharging the Main Unit s internal battery from an external DC power source requires the use of the DC Recharge Cable and the Inverter Power Cable...

Страница 16: ...harging adapters cables etc contact Vector Technical Support 954 584 4446 or call toll free 866 584 5504 Except for a fuse in the inverter and a lamp in the Lantern there are no user serviceable parts...

Страница 17: ...ower Inverter Continuous 200 Watt 60 Hz 110 120 VAC Power Inverter Peak 300 Watt 60 Hz 110 120 VAC Inverter Waveform Modified Sine Wave Inverter DC Input Range 10 0 to 14 6 VDC Inverter Audible Alarm...

Страница 18: ...cratches abrasions repairs by unauthorized persons or failure to follow recommended care and use instructions Damage caused by misuse abuse neglect alterations repairs by unauthorized persons or failu...

Страница 19: ...instructions Damage caused by misuse abuse neglect alterations repairs by unauthorized persons or failure to follow recommended care and use instructions Bulbs and batteries Please activate my Extende...

Страница 20: ...20 2000 VECTOR MANUFACTURING Ltd FT LAUDERDALE FL 33312 MADE IN CHINA...

Отзывы: