7.1

AC RECHARGE

AC Recharge requires the use of the supplied AC/DC Adapter. The adapter must be powered

from 110 volt AC, 60 Hz North American standard household AC receptacles.

The Battery Status Display will automatically activate during AC recharge. As recharge

progresses, the red LEDs will light one by one. Charge the Power City until the Battery Status

Display lights the green FULL LED. Continue to recharge for one to two hours, and then discon-

nect the AC Recharger. AC recharge is an automatic float and taper charge and The AC

Recharger can be left connected to the Main Unit for long periods. See Figure 2 for AC Re-

charge connection to the Main Unit. Refer to Section 7.2 for Recharge Method.

Make sure that the inverter, compressor and lamp ON/OFF Switches are in off position during

AC recharging.

7.2

DC RECHARGE

Power City is supplied with two accessory cables. One cable is a black Inverter Power Cable

with an attached thinner Lantern Extension Cord. It is to power the inverter when it is used with

another accessory socket in a vehicle or boat. An attached thinner wire is dubbed Lantern

Extension Cord" and it is used to power the Lantern.  The DC Recharge Cable has red and black

wire and it mates with the Inverter Power Cable to make a DC to DC cable.

After recharge, the accessory cables are stored in their own Cable Storage Hatch in the Main Unit.

Recharging the Main Unit’s internal battery from an external DC power source requires the use

of the DC Recharge Cable and the Inverter Power Cable. See Figure 11.  The Lantern Extension

Cord  can be connected to the Lantern to simultaneously recharge the Main Unit and power the

Lantern (not shown).

FIGURE 12

Make sure Safety ON/OFF Switch, inverter, and compressor switches are in the OFF position

during DC recharging.

Unlike the AC Recharge method, DC Recharge does not automatically activate the Battery

Status Display. To check the battery status, press the Battery Status Display Push-button. If the

Jump Starter's battery is fully discharged, it is recommended that the host vehicle or boat's

engine being used for recharging be left operating while the unit is being charged using the 12

volt DC/DC method.

WARNING:

 DO NOT recharge main unit for more than 8 hours maximum using 12 volt DC

method. do not charge lantern for more than five hours using the dc recharge method.

1. Remove both power cables from the Cable Storage Hatch.

2. Insert the red DC Recharge Cable's rectangular connector flat pins into the black rectangular

connector on the Inverter Power Cable.

3. Insert black DC Plug on the Inverter Power Cable into a DC Accessory socket on the

Main Unit.

4. Plug the red DC Plug into an accessory socket in a vehicle, power supply or other 12 VOLT

DC source.

LANTERN

EXTENSION

CORD

BARREL

CONNECTOR

DC RECHARGE

PLUG

INVERTER

POWER CABLE

CONNECTOR

PAIR

DC PLUG

Содержание Power City VEC029AC

Страница 1: ...ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN POSSIBLE INJURY OR PROPERTY DAMAGE 4140 SW 28TH WAY FT LAUDER...

Страница 2: ...puterized systems may be damaged if vehicle battery is jumpstarted Before jumpstarting this type of vehicle read the vehicle s owner s manual to confirm that external starting assistance is advised Ex...

Страница 3: ...verter fuse replacement 11 5 COMPRESSOR TIRE INFLATOR 11 5 1 Compressor Use 11 5 2 Warnings 11 5 3 Tire Inflation or products with a valve stem 12 5 4 Inflate other articles without valve stem 12 5 5...

Страница 4: ...terminals while preparing to jumpstart a dead battery in the dark changing a tire etc Power City is also ideal to power 12 volt DC cordless portable rechargeable appliances with ratings up to 23 ampe...

Страница 5: ...and power hand tools cellular phones camcorders power tool rechargeable batteries that have an appropriate recharging adapter with a 110 volt AC standard type plug Operate using 23 ampere rated 12 Vo...

Страница 6: ...clamp end of cable 8 Squeeze positive red clamp handles and slide clamp from holster 9 Connect positive red clamp to vehicle s positive battery terminal 10 Connect negative black clamp to chassis or a...

Страница 7: ...e inverter and it is operating properly The red LED when lit indicates that something caused the inverter to shut down The green LED will not be lit under shutdown conditions Inverter shutdown is caus...

Страница 8: ...11 and 14 5 volts DC and must be able to supply the necessary current amps to operate the load The power source may be a battery or a well regulated DC power supply To obtain a rough estimate of the...

Страница 9: ...sound it s alarm when DC voltage drops to 10 6 volts CAUTION Reverse polarity connection will result in damage to the inverter THIS WILL VOID THE WARRANTY If the inverter is connected to the incorrec...

Страница 10: ...iece of equipment that is generating heat above room temperature Keep the inverter away that from direct sunlight if at all possible VENTILATED Keep the area surrounding the inverter clear to ensure f...

Страница 11: ...ccessory socket 5 COMPRESSOR TIRE INFLATOR This built in 12 Volt DC compressor is the ultimate compressor for all Vehicles Trailer Tires and recreational inflatables Three different sized nozzles are...

Страница 12: ...very rapidly 5 Insert adaptor e g needle into item to be inflated and inflate to desired pressure 6 Turn ON compressor switch inflate to desired pressure or fullness refer to paragraph 5 5 7 Remove ad...

Страница 13: ...Main Unit using the Inverter Power Cable with attached Lantern Extension Cord This allows great flexibility in positioning the Lantern during tire infla tion and during under the hood inspections See...

Страница 14: ...BATTERY Lead acid batteries require maintenance to maintain a full charge and to ensure good battery life All lead acid batteries suffer from self discharge over time and more rapidly when they are a...

Страница 15: ...ed in their own Cable Storage Hatch in the Main Unit Recharging the Main Unit s internal battery from an external DC power source requires the use of the DC Recharge Cable and the Inverter Power Cable...

Страница 16: ...harging adapters cables etc contact Vector Technical Support 954 584 4446 or call toll free 866 584 5504 Except for a fuse in the inverter and a lamp in the Lantern there are no user serviceable parts...

Страница 17: ...ower Inverter Continuous 200 Watt 60 Hz 110 120 VAC Power Inverter Peak 300 Watt 60 Hz 110 120 VAC Inverter Waveform Modified Sine Wave Inverter DC Input Range 10 0 to 14 6 VDC Inverter Audible Alarm...

Страница 18: ...cratches abrasions repairs by unauthorized persons or failure to follow recommended care and use instructions Damage caused by misuse abuse neglect alterations repairs by unauthorized persons or failu...

Страница 19: ...instructions Damage caused by misuse abuse neglect alterations repairs by unauthorized persons or failure to follow recommended care and use instructions Bulbs and batteries Please activate my Extende...

Страница 20: ...20 2000 VECTOR MANUFACTURING Ltd FT LAUDERDALE FL 33312 MADE IN CHINA...

Отзывы: