INSTRUCTION MANUAL

Thank you for purchase of “Remote Operator”. This manual explains about 

treatment of “Remote Operator”. By reading this manual and an instruction manual of 

inverter use practically for installation, maintenance, and inspection.  After reading this 

manual, keep it handy for future reference. 

Make sure to reach this manual to the end user.

After reading this manual, keep it handy for future reference.

 

HITACHI  INVERTER

REMOTE OPERATOR

WOP

N T 2 1 4 X

Microlectra bv.

 

 

 

www.microlectra.nl   

                 [email protected]

Summary of Contents for REMOTE OPERATOR WOP

Page 1: ...tion manual of inverter use practically for installation maintenance and inspection After reading this manual keep it handy for future reference Make sure to reach this manual to the end user After reading this manual keep it handy for future reference HITACHI INVERTER REMOTE OPERATOR WOP N T 2 1 4 X Microlectra bv www microlectra nl info microlectra nl ...

Page 2: ...ided can result in minor to moderate injury or serious damage to the product This situation described in the CAUTION may if not avoided lead to serious results Important safety measures are described in CAUTION as well as WARNING so be sure to observe them NOTE NOTE Notes indicate an area or subject of special merit emphasizing either the product s capabilities or common errors in operation or mai...

Page 3: ... gases explosive gases combustible gases coolant mist and sea damage etc Install indoors to avoid direct sunlight and the unit should be well ventilated Otherwise there is a danger of electric shock and or injury Revision History Table No Revision Contents The Date of Issue Instruction Manual No 1 Initial Release MAY 2013 NT214X WARNING CAUTION SAFETY PRECAUTIONS ...

Page 4: ...mode 10 4 2 Operation of Monitor mode A 12 4 3 Operation of Monitor mode B 13 4 4 Operation of Function mode 14 4 5 Operation of Trip mode 15 4 6 Operation of Option mode 16 Chapter 5 Read Write function and operation 19 5 1 R W Storage Mode Single READ function 20 5 2 R W Storage Mode Single WRITE function 21 5 3 R W Storage Mode Quad READ function 22 5 4 R W Storage Mode Quad VERIFY function 24 ...

Page 5: ...6 characters 1 lines N A English Only When using X200 set the inverter type to 2 Refer to section 4 6 SJ700 L700 series NOTE 3 16 characters 2 lines A English Only When using SJ700 L700 set the inverter type to 2 Refer to section 4 6 NE S1 series 22 characters 5 lines N A English Only NOTE 1 When using WJ200 before Ver 2 0 only READ WRITE function is available NOTE 2 Refer to section 4 6 for more ...

Page 6: ... or damaged caused by mis operation or modification or improper repair 2 Malfunction or damaged caused by a drop after purchase and transportation 3 Malfunction or damaged caused by fire earthquake flood lightning abnormal input voltage contamination or other natural disasters The warranty covers WOP only Any damage caused to third party equipment by malfunction of the remote operator is not cover...

Page 7: ...tion command is set in operator 7 LCD display Refer to section 2 4 for details 8 Operation key Refer to Tab 3 for details 9 Connector It can be connected to the main body of the Inverter via a cable optional 10 Hole for installation It is the hole for installation on the control panel Please fix with M3 screw 11 Battery exchange cover fixation screw Please unscrew this one and detach the cover for...

Page 8: ...seconds again 2 READ The key is used to transfer inverter parameters to the WOP s memory Refer to chapter 5 for more details 3 WRITE The key is used to copy the parameter settings in WOP to inverter Refer to chapter 5 for more details 4 ESC Back to above layer Cancel the change of parameter 5 SET Go ahead to below layer When at edit layer the change of set will be stored and back to above layer vi...

Page 9: ...ET The key is used to stop the motor or reset an alarm It is also possible to invalidate the STOP key when setting parameter The key does not response when WOP reads or writes the parameters from or to inverter 2 3 Initialize Inverter According to the following procedure to initialize inverter via WOP Inverters Initializing procedure WJ200 series Ver 2 0 or above Set parameter b180 Please refer to...

Page 10: ...s as described in Tab 4 Tab 4 Backlight colors of LCD display Backlight Color Contents White Normal It is not related to inverter s driving stop Orange Warning Parameter mismatch White Orange Alternate blinking for one second Trip The same as ALARM LED The details of LCD display When connecting to WJ200 Ver 2 0 or above or NE S1 the first line of LCD monitor always displays the display mode the nu...

Page 11: ... M2 The second control object STOP Stopped FWD Forward running The state of inverter REV Reverse running ALL Display all UTL Each function display USR User setting display CMP Data compare display BAS Basic display The display selection b037 MON Monitor display only NOTE1 The number for the control object is a motor number when two or more motors are switched and controlled Refer to Inverter instr...

Page 12: ...ponse because of absence of the function Move to monitor mode Monitor MON key READ Reading of parameter Reading of parameter Read READ key WRITE Writing of parameter Writing of parameter Copy COPY key ESC Back to the upper layer Move to function mode Function FUN key SET Store the setting value Enter the lower layer Store the setting value Store STR key POWER LED Power on RUN LED Inverter is runni...

Page 13: ...d Otherwise please use the cable with appointed dimension Tab 7 Recommended cable Model Content ICS 1 1m cable ICS 3 3m cable Make sure to use a straight cable within 3m in length and 10BASE T category 5 CAT5 of UTP or STP when the cable is prepared by the customer NOTE UTP Unshielded twist pair cable STP Shielded twist pair cable Chapter 3 Connection wiring and attaching Fig 4 Diagram for punched...

Page 14: ...le they can be changed at Edit layer Please see figure below When pressing SET key at Navigation layer a cursor will appear and screen will move to below layer Fig 5 Outline of mode transition Monitor mode A Monitor mode B Function mode Trip mode Monitor mode A Monitor mode A Monitor or function code selection Change parameter settings Monitor mode B Monitor row selection Monitor mode B Monitor it...

Page 15: ...ameters are not displayed Function mode Setting In this mode F A b C H P U group parameters can be displayed and setted Function code function name parameter content and parameter range are displayed NOTE d group inverter parameter cannot be setted and displayed in this mode Trip mode Trip information and warning information are displayed in this mode When inverter trip or warning happens the pres...

Page 16: ...em F001 as right figure then pressing the or key to change the function code 3 It entries into the below layer after pressing the SET key and the cursor appears on the parameter part of a function item Pressing the or key to change data It returns to the upper layer after storing parameter via pressing the SET key And the change is cancelled and returns to the upper layer via pressing the ESC key ...

Page 17: ...ries into the below layer after pressing the SET key and the cursor appears at the function code of the item Pressing the or key to select the code After pressing the SET key the monitor item is selected and it returns to the upper layer After pressing ESC key the change is cancelled and returns to the previous display MONITOR B M1 STOP ALL d001 Output FQ SET ESC Output FQ 0 00Hz Output LLL MONITO...

Page 18: ...right diagram then pressing the or key to change the function code 3 It entries into the below layer after pressing the SET key Pressing the or key to select the data which you want to set It returns to the upper layer after storing parameter via pressing the SET key Pressing the ESC key will cancel the change and returns to the upper layer F001 0 00 50 00 FUNCTION M1 STOP ALL Set Frequency OPE 6 ...

Page 19: ... backlight state becomes flicker whatever the state of Backlight Auto off is Refer to section 4 6 SET ESC ERR1 P1 UnderVoltage Output current 0 00A TRIP M1 STOP ALL 10 07 18 11 52 Const Output FQ 6 00Hz ERR1 P2 UnderVoltage ON time 186hr TRIP M1 STOP ALL DC Voltage 172 3Vdc RUN time 3hr ERR6 P1 UnderVoltage Output current 0 00A TRIP M1 STOP ALL 10 07 18 10 20 Accel Output FQ 4 85Hz ERR6 P2 UnderVo...

Page 20: ...e below layer and edit the item directly After set the required data via pressing the or key pressing the SET key to store the parameter and return to the upper layer Pressing the ESC key will cancel the change and returns to the upper layer OPTION MODE 01 English Language 1 Language 4 LCD Backlight OPTION MODE 3 Read Lock 2 Set Clock SET ESC SET OPTION MODE 01 English Language 1 Language 4 INV Ty...

Page 21: ...en saved from being overwritten If the state of Read Lock is 01 Enable READ operation is impossible NOTE3 01 Enable 02 Disable Disable 4 INV Type Select Selecting the correct inverter type COM ERROR will be displayed if the incorrect inverter type was selected 01 Type 1 WJ200 Ver 2 0 or above NE S1 NOTE4 02 Type 2 L700 SJ700 X200 Type 1 5 R W Storage Mode Reflecting the quantity of setting of para...

Page 22: ...2 0 or above or NE S1 Clock display function d031 is provided as following diagram NOTE 3 When Read Lock is setted to 01 Enable READ operation is unavailable display as follows Pressing ESC key will return to the previous display NOTE4 When connecting to WJ200 Ver 2 0 or above please set INV Type Select to 01 Type 1 read copy only will display if 02 Type 2 is selected NOTE5 Please do not execute t...

Page 23: ...verters NE S1 WJ200 Ver 2 0 WJ200 before Ver 2 0 SJ700 2 SJ700 1 L700 X200 Type code INV89 INV81 INV78 INV71 INV64 INV80 INV65 For example 1 100718 14 50 INV81 displayed on screen means that the parameter of WJ200 Ver 2 0 INV81 were saved in the first block of wop s memory at 14 50 on July 18 2010 Usually parameter can not be copied between different type Inverters If Read operation and parameter ...

Page 24: ...at the data saved in WOP will be overwritten NOTE All inverter parameters saved in WOP are overwritten after pressing the READ key Read completed will display for 2 seconds READ Parameter reading When parameter read is completed it will return to previous display automatically d001 Output FQ 0 00Hz F001 0 00Hz MONITOR A M1 STOP ALL please keep power ON READ Data reading OPE INV READ Completed The ...

Page 25: ...us display automatically Parameter writing WRITE please keep power ON WRITE Data writing OPE INV WRITE Completed d001 Output FQ 0 00Hz F001 0 00Hz MONITOR A M1 STOP ALL The Inverter with EzSQ function The Inverter without EzSQ function please keep power ON WRITE Data writing OPE INV please keep power ON WRITE EzSQ writing OPE INV d001 Output FQ 0 00Hz F001 0 00Hz MONITOR A M1 STOP ALL WRITE Comple...

Page 26: ...hat one EzSQ program takes up memory area of three sets of inverter parameters which are No 2 No 3 and No 4 Parameter of inverter 1 Parameter of inverter 2 Parameter of inverter 3 Parameter of inverter 4 Memory image of operator When without EzSQ Parameter of inverter 1 EzSQ program of inverter 1 Memory image of operator When with EzSQ Parameter of inverter 1 EzSQ program of inverter 1 Parameter o...

Page 27: ...firming screen are displayed after the SET key is pressed If approving press the SET key if not press the ESC key It returns to the navigation layer of read mode automatically after the read is completed the read operation date and time inverter type will be updated If EzSQ program is saved in WOP the No 2 No 3 No 4 will display E as described in the right figture Transform automatically Transform...

Page 28: ...a EzSQ 03 Verify data 04 Verify EzSQ 05 Cancel The result is shown automatically after the parameter or EzSQ verification is completed It returns to navigation level of Read mode after the ESC is pressed Transform automatically Data No 1 Select data 03 Verify data READ SET ESC READ Data verifying OPE INV please keep power ON SET ESC Press ESC key READ Data matched ESC E READ E E 1 100718 14 50 INV...

Page 29: ... 2 No 3 or No 4 is selected The parameters are written after the SET key is pressed The display of data is shown as described in the right figture After the parameter writing is completed it returns to navigation level of the write mode automatically Transform automatically Transform automatically SET ESC Data No 1 WRITE Select data 01 Write data SET ESC please keep power ON WRITE Data writing OPE...

Page 30: ...tate and setting of inverter Only parameter Parameter EzSQ Inverter is running EzSQ is running written unable Invalid Invalid Soft locked b031 Invalid Invalid Display is limited b037 Valid Valid Trip happened Invalid Invalid NOTE When R W Storage Mode is setted to 01 Single Refer to section 4 6 E09 3 UnderVoltage 10 07 18 11 52 Const TRIP M1 STOP ALL Press ESC key WRITE INV in TRIP mode E09 3 Unde...

Page 31: ...ter the SET key be pressed 001 060 Display set by d001 d060 201 Display of F001 202 Monitor mode B of WOP 7 b081 Data R W selection Restrict the data read write by operator 00 Data read write enable 01 Data read enable write disable 02 Data read disable write enable 03 Data read write disable 8 b087 Stop key selection Make the STOP key of operator enable disable 00 Enable 01 Disable 02 Enable when...

Page 32: ...E key is pressed while the inverter is running Soft lock is turned ON Check if the WRITE key is pressed while the inverter is running Check if the WRITE key is pressed while Soft Lock is ON The WRITE key should be pressed only while the inverter stops Release the Soft Lock of the inverter INV Type Un match An attempt was made to write parameter between different type inverters Check inverter type ...

Page 33: ...tive noise or not Please put WOP and its cable far away from the inductive noise Please set the right date in option mode change the battery Battery power is exhausted Whether right date displays in parameter d031 Refer to Fig 7 Please replace it with new battery please set the clock wop is used at the first time wop is used at the first time after battery replaced WOP is used at the first time af...

Page 34: ...the inverter power supply or reset the terminal reset signal 4 In case of changing to connect to WOP from other operators such as OPE S while inverter power is on it is possible that wop can not display correctly You can restore power to inverter to correct it The inverter power supply is ON Turn ON the inverter power supply YES The cable is connected properly to both the inverter and the remote o...

Page 35: ...erature 10 to 50 Humidity 20 to 90 RH no dew condensation Store temperature 20 to 65 Place to use 1000m or less in height at a place without corrosion gas and dust Seat color Black Others Built in real time clock NOTE 2 Backup time Including power OFF status time About 2 years 25 Built in battery Coin type lithium battery CR1220 NOTE 1 For more information refer to section 4 6 NOTE 2 Because of th...

Page 36: ...32 9 2 Dimensions Fig 6 Dimension of WOP Chapter 9 Specification ...

Page 37: ...ry please take off the battery cover by removing one screw of the operator backside Please take out the old battery with a thin minus driver and be careful not to damage PCB and any part on the PCB The positive pole of the battery flat one must be installed upward the negative pole face to substrate And inserting the battery press the battery to reach the edge of the metal case In addition please ...