Parts List (Models 2005, 2006, 2007)

Notes:

•   Models 2006 and 2007 use 0.5 mm shims to adjust the hose 

compression.

•   Model 2005 uses the same style of roller assembly as Models 

2002 – 2004 (see previous page.

  Ref. 

 

Qty, per

  No. 

Description 

Pump

  1 

Casing................................................................ 1

  2 

Cover, front ........................................................ 1

  3 

Window, cover ................................................... 1

  5 

Roller assembly ................................................. 1

  6 

Clamp, hose....................................................... 4

  7 

Screw, cover ............................................... 2 or 3

  8 

Hose .................................................................. 1

  10 

Screw, roller ....................................................... 1

  Ref. 

 

Qty, per

  No. 

Description 

Pump

  16 

Connector, hose ................................................ 1

  17 

Base ................................................................... 1

  18 

Bolt, mounting ................................................... 4

  19 

Washer .............................................................. 4

  20 

Washer .............................................................. 4

  21 

Bolt, cover .......................................................... 4

  23 

Support, hose .................................................... 2

  24 

Washer, roller mounting .................................... 1

  25 

Bolt ..................................................................... 4

  26 

Washer ................................................................

  — 

Shim, 0.5 mm (.02 in.) ............................... 8 max

© 2004 Wanner Engineering, Inc. Printed in USA

VEC-991-2400A 10/2004, Revised 8/2007

Содержание 2003

Страница 1: ...s MN 55403 TEL 612 332 5681 FAX 612 332 6937 TOLL FREE FAX US only 800 332 6812 www vectorpump com email sales wannereng com W0453 Installation and Operation Manual VEC 991 2400A Vector 2000 Series Mo...

Страница 2: ...ses a pulsation dampener may be required to absorb excessive pulsation caused by high pump speed and long discharge lines Limited Warranty Wanner Engineering Inc extends to the original purchaser of e...

Страница 3: ...Pharmed name on hose Fiber Braided Hypalon HF Black color yellow stripe double braided EPDM EF Black color white stripe double braided Natural Rubber NF Black color green stripe double braided standar...

Страница 4: ...ot be adjusted with equal pressure on the hose See Figure 3 If the hose fails in area A this may occur from operating the pump at a discharge pressure higher than the hose is rated for or with a close...

Страница 5: ...steps 2 thru 6 Service Models 2002 2003 2004 2005 Setting Roller Pressure Note This pressure setting must be checked when a new hose is installed because of variations in hose thickness 1 Remove front...

Страница 6: ...oosen clamp bolts Remove hose supports and clamps that secure both ends of hose 6 Remove hose from pump casing 7 Pull cut hose if needed hose connectors from worn hose Clean if reusable 8 Carefully cl...

Страница 7: ...Casing 1 2 Cover front 1 3 Window cover 1 4 Bracket mounting 1 5 Roller assembly 1 6 Clamp hose 2 7 Screw cover 1 or 2 8 Hose 1 9 Key motor non shown 2 10 Screw roller 1 Ref Qty per No Description Pu...

Страница 8: ...he same style of roller assembly as Models 2002 2004 see previous page Ref Qty per No Description Pump 1 Casing 1 2 Cover front 1 3 Window cover 1 5 Roller assembly 1 6 Clamp hose 4 7 Screw cover 2 or...

Отзывы: