background image

5

Wanner Engineering, Inc.

United States 

Instant Information:   www.vectorpump.com

(61) 33-5681   Fax (61) 33-6937                                   VEC-991-400A

Install New Hose

1.  Check for correct length of hose:
 

Model 2002: 13 in. (330 mm)

 

Model 2003: 15 3/8 in. (390 mm)

 

Model 2004: 23 1/4 in. (590 mm)

 

Model 2005: 33 7/8 in. (860 mm)

2.  Install connectors in new hose.
3.  Make sure that pressure rollers are in same position as before. 

See Remove Old Hose, Step 3.

4.  Position bent hose inside pump casing.
5.  Push upper connector against end of pump casing. Install 

top hose clamp and secure its bolt.

6.  Repeat Step 5 on lower connection.
 

Important:

  On  models  2002  through  2005,  make  sure  the 

hose lays completely against the inside of the pump casing. 

7.  Smear  non-petroleum  silicone  grease  on  inner  surface  of 

hose (where rollers contact hose).

8.  Set  roller  pressure  according  to  procedure  following 

(steps 2 thru 6).

Service (Models 2002, 2003, 2004, 2005)

Setting Roller Pressure

Note: 

This pressure setting must be checked when a new hose 

is installed, because of variations in hose thickness.
1.  Remove front cover from pump.
2.  See Figure 6. Loosen all roller bracket screws and slide both 

rollers  away  from  the  hose  to  reduce  compression  on  the 

hose. Retighten all roller bracket screws.

4.  Test pump in full operation, and readjust as necessary.
5.  Reattach front cover.

 

a.  If there is vacuum on first attempt, rollers are set. 

 

b.  See Figure 8. If not enough vacuum, gradually move rollers 

forward  in 1/32 to 1/8 in. (0.8 to 3.0 mm) increments and 

repeat test until suction seems to be correct. (Make sure 

compression is same for both rollers by measuring roller 

bracket in relation to rectangular rotor block).

3.  See Figure 7. Start pump. Place palm of hand over suction 

opening and check for vacuum.

W0460

Roller adjustment
position

Figure 6

W0461

Inlet (Suction)
    Opening

Figure 7

W0462

Measure
   here.

Measure
   here.

These two dimensions
should be the same.

Figure 8

Содержание 2003

Страница 1: ...s MN 55403 TEL 612 332 5681 FAX 612 332 6937 TOLL FREE FAX US only 800 332 6812 www vectorpump com email sales wannereng com W0453 Installation and Operation Manual VEC 991 2400A Vector 2000 Series Mo...

Страница 2: ...ses a pulsation dampener may be required to absorb excessive pulsation caused by high pump speed and long discharge lines Limited Warranty Wanner Engineering Inc extends to the original purchaser of e...

Страница 3: ...Pharmed name on hose Fiber Braided Hypalon HF Black color yellow stripe double braided EPDM EF Black color white stripe double braided Natural Rubber NF Black color green stripe double braided standar...

Страница 4: ...ot be adjusted with equal pressure on the hose See Figure 3 If the hose fails in area A this may occur from operating the pump at a discharge pressure higher than the hose is rated for or with a close...

Страница 5: ...steps 2 thru 6 Service Models 2002 2003 2004 2005 Setting Roller Pressure Note This pressure setting must be checked when a new hose is installed because of variations in hose thickness 1 Remove front...

Страница 6: ...oosen clamp bolts Remove hose supports and clamps that secure both ends of hose 6 Remove hose from pump casing 7 Pull cut hose if needed hose connectors from worn hose Clean if reusable 8 Carefully cl...

Страница 7: ...Casing 1 2 Cover front 1 3 Window cover 1 4 Bracket mounting 1 5 Roller assembly 1 6 Clamp hose 2 7 Screw cover 1 or 2 8 Hose 1 9 Key motor non shown 2 10 Screw roller 1 Ref Qty per No Description Pu...

Страница 8: ...he same style of roller assembly as Models 2002 2004 see previous page Ref Qty per No Description Pump 1 Casing 1 2 Cover front 1 3 Window cover 1 5 Roller assembly 1 6 Clamp hose 4 7 Screw cover 2 or...

Отзывы: