background image

AW 13s-63s, 13a-63a

12

GB

Accessories AW a-s (see appendix B)

Filter AWPF. 

A flat filter to be fitted in AW13-63, between the fan 

and the water battery.

Air deflector AWLH. 

As standard, the fan heater always comes with an air 

deflector that directs the air downwards. Available acces-

sories include air deflector AWLH, which deflects the air 

sideways.

Air accelerator AWLA 

Extends the horizontal range by 40% on average. 

Cannot be used together with AWLH. 

To be fitted acc. to separate instructions.

Wall bracket AWV 

Used to mount the fan heater on a wall or to mount it on 

a ceiling for a vertical air stream.

Ceiling bracket AWT.  

Used to mount the fan heater on a ceiling for a horizontal 

air stream. 

May also be used together with the wall bracket.

Safety Information

This appliance may be used by children aged eight years or above, people with physical and mental disabilities as well as 

those who lack any experience, provided that they have received detailed instructions 

about the functionality of the appliance and any risks. Never allow children to play with the appliance. Cleaning and 

maintenance must not be performed by children without proper supervision. Children under three years of age should 

not be near the appliance without constant supervision. 

Children between three and eight years old may only turn on/shut off the appliance if it is located in a suitable position 

and they have received instructions about the proper course of action, or are being supervised. They shall also be infor-

med about possible dangers. 

Children between three and eight years old may not connect the device, change its settings or perform care/maintenance.

 

CAUTION

 

–   Parts of this appliance can get hot and cause burns. 

 

Children and vulnerable people must be kept under supervision.

The fan heater is available in four sizes: AW 13, AW 23, AW 43, and AW 63.  

The EC version of AW-s will only operate with the fan at full speed, whereas the other models have three fan speeds. 

The AC version of the fan heater and AW 63 EC have an IP 44 rating. The other EC fans have an IP 54 rating. Both 

ingress protection ratings allow installation in dry, humid and wet rooms. Model AW-a is supplied with a valve.  

See Appendix A for technical data on the fan heaters.

AW 13s, -23s, -43s, -63s.

These fan heaters do not have built-in controls. The fan motor and the water supply are controlled using external components. 

A frost protection must be installed in locations where there is a risk of frost.

AW 13a, -23a, -43a, -63a.

The fan heater has built-in controls and may only be used in locations where there is no risk of frost. The fan heater inclu-

des an electronic three-stage thermostat that provides three-speed control of the fan according to the heat requirement. 

The thermostat works with intermittent fan operation, i.e. the fan motor also comes to a stop when there is no heat requi-

rement. This minimises soiling of the water battery and of any possible filters. The speed adjustment, which keeps the fan 

at the lowest possible air volume, also minimises 

soiling. The three-stage control also means that the fan heater can operate at the lower speeds for most of the year, thereby 

minimising the noise level. A valve and actuator assembly controls the water flow by turning it on or off. 

The opening and closing time lasts 15 seconds respectively. The valve opens at the same time as the fan starts at low speed. 

A room sensor with setpoint adjuster (TG-R430) or a room sensor (TG-R530 or TG-R630) with separate setpoint adjus-

ter (TG-R430) is required to control the unit. The thermostat is incremented in steps of 1 °C. 

As an alternative to the TG sensor, an external 0... 10 V DC control signal can be connected to the electronic thermostat. 

AW-a also includes an outgoing control signal. This function is available regardless of whether a TG sensor or an 

incoming 0...10 V control signal is used. The outgoing control signal can control up to five additional AW-a or CAW-

a units as slaves. 

(CAW-a is VEAB’s range of ceiling-mounted fan heaters.) If more than 5 fan heaters are to be controlled as slaves 

using a common sensor or 0...10 V control signal, the control signal output by an AW-a slave must be used.

Examples of how to connect sensors or control signals can be found in appendixes F, G, H and N (J, L and M for EC) 

in this folder.

Содержание AW 13a-63s

Страница 1: ...ahren Sie die Betriebsanleitung f r den zuk nftigen Betrieb auf 18 Manual for fan heaters unit water IMPORTANT Please read this manual before installing connecting and putting the product into use Sav...

Страница 2: ...ktdrift dvs ven fl ktmotor stannar n r inget v rmebehov finns Detta medf r att nedsmutsningen av vattenbatteri och eventuella filter minimeras ven varvtalsregleringen som h ller fl kten p l gsta m jl...

Страница 3: ...ets pl tkant tryck sedan filtret mot andra sidan av vattenbatteriet s att filtrets U profil greppar vattenbatteriets bortre kant se bild 2 Luftriktare f r luft i sidled AWLH 1 Montera luftriktaren p v...

Страница 4: ...r m ste luftriktaren v ndas om luften skall riktas ned t Lossa de sex skruvarna som h ller luftriktaren enl bild 8 och tag ut luftriktaren och vrid den ett halvt varv Skruva d refter fast den igen 5 V...

Страница 5: ...n monteras avluftningsventil 5 Vid terdragning av kl mringskopplingar p anslutningsr r eller ventiler skall dessa h llas fast s att vridkraft ej verf rs till v rmefl ktens in och utloppsr r 6 Anslutet...

Страница 6: ...risontalt med oberoende fl desriktning Anslutningen till st lldonet riktas rakt upp f r att st lldonets IP klassning ska bibeh llas Drag t ventilens kl mringskopplingarna f r hand och sedan 1 varv Los...

Страница 7: ...17 eller bilaga D f r EC bilaga I 6 Borra det antal h l som beh vs f r installation i kopplingsl dan och montera kabelgenomf ring 7 Termostaten som skall styra v rmefl kten b r monteras s att den ej...

Страница 8: ...nds kan max en resp tv AW S EC v rmare kopplas in 5 Ventil med kapslingsklass IP44 bild 24 max vattentemperatur 90 C och tryckklass PN25 25 bar Anv nds tillsammans med termostat R31 SR121 1 Mer inform...

Страница 9: ...R430 se bild 28 som har skyddsform IP30 Rumsgivaren b rv rdesomst llaren b r monteras s att den ej p verkas av drag fr n d rrar och f nster som ppnas v rmefl ktens utbl s eller dyl Om man vill ha en...

Страница 10: ...fel NTC ing ng plint 1 2 Snabb periodisk terkommande blinkning Internt fel styrkort sj lv vervakning Tv snabba periodiskt terkommande blinkningar SE Bilaga A Sortiment versikt Typ AW13 AW23 AW43 AW63...

Страница 11: ...mperatur 18 C Kastl ngden r definierad som avst ndet fr n fl ktluftv rmaren till den punkt d r lufthastigheten r 0 2 m s 3 Luftfl det vid l g mellan och h gvarv f r EC g ller modell a Modell s har end...

Страница 12: ...s have an IP 54 rating Both ingress protection ratings allow installation in dry humid and wet rooms Model AW a is supplied with a valve See Appendix A for technical data on the fan heaters AW 13s 23s...

Страница 13: ...st the other side towards the water battery in such a way that the U profile of the filter engages with the far end of the water battery see figure 2 Air deflector AWLH for deflecting the air sideways...

Страница 14: ...g right the air deflector must be turned around for the air to be deflected downward Remove the six screws that hold the air deflector as shown in figure 8 then take off the air deflector and turn it...

Страница 15: ...tem 5 When tightening compression fittings on connection pipes and valves these must be held in place so that the torsional force is not transferred to the inlet and outlet pipes of the fan heater 6 T...

Страница 16: ...respective of the direction of flow The connection to the actuator must point straight up to preserve the actuator s IP rating Tighten the valve s compression fittings by hand and then tighten one ad...

Страница 17: ...er see figure 17 or appendix D appendix I for EC 6 Drill the number of holes required for installation in the terminal box and mount cable glands 7 The thermostat that controls the fan heater must be...

Страница 18: ...two AW s EC heaters can be connected 5 Valve with IP44 rating figure 24 maximum water temperature 90 C and pressure class PN25 25 bar To be used together with the thermostats R31 and SR121 1 More inf...

Страница 19: ...ermostat see figure 28 The room sensor setpoint adjuster must be installed where it will not be affected by draughts from open doors or windows the outlet air from the heater itself etc For a separate...

Страница 20: ...Intermittent fast flashing light Internal error control board self monitoring Two fast intermittent flashes GB Appendix A Product Range Overview Type AW13 AW23 AW43 AW63 Voltage Frequency 230 VAC 50...

Страница 21: ...r temperature of 40 C and room temperature of 18 C The horizontal range is defined as the distance from the fan air heater to the point where air velocity is 0 2 m s 3 The air flow at low medium and h...

Страница 22: ...gderAW a ModelleistjeweilseinVentilenthalten ZudentechnischenDatenderHeizl ftersieheAnhangA AW13s AW23s AW43s AW63s DieseHeizl fterhabenkeineintegrierteSteuerung StattdessenerfolgtdieL ftermotor undWa...

Страница 23: ...ch schieben dann das Filter zur anderen Geh useseite zum Heizregister hin dr cken sodass das U Profil des Filters auf der gegen berliegenden Seite einrastet siehe Bild 2 AWLH Luftrichter f r vertikale...

Страница 24: ...rmitdenRohrennachrechtsmontiertwerden mussderLuftrichterumgedrehtwerden wenn derLuftstromnachuntenweisensoll IndiesemFalldiesechsBefestigungsschraubendesLuftrichtersl sen sieheBild8 DenLuftrichterabne...

Страница 25: ...ntl ftungsventil montieren 5 Beim Anziehen der Klemmverbinder an den Anschlussrohren oder Ventilen die Verbinder festhalten sodass die Torsionskr fte nicht auf die Ein und Auslassrohre bertragen werde...

Страница 26: ...schluss f r den Stellantrieb gerade nach oben richten um die angegebene Schutzart zu gew hrleisten Die Klemmverschraubungen des Ventils zun chst handfest dann um eine weitere Umdrehung anziehen Anschl...

Страница 27: ...r Drehzahl erfolgen gem dem im Deckel angebrachten Anschlussplan siehe Bild 17 oder Anhang D bei EC Anhang I 6 Die f r die Montage ben tigten L cher in den Anschlusskasten bohren und die Kabel in den...

Страница 28: ...iner bzw zwei EC Heizer vom Typ AW s angeschlossen werden 5 Ventil der Schutzklasse IP44 Bild 24 max Wassertemperatur 90 C Druckklasse PN25 25 bar Verwendung zusammen mit Thermostat R31 SR121 1 Weiter...

Страница 29: ...IP30 angeschlossen siehe Bild 28 Den Raumf hler Sollwerteinsteller vor Zugluft durch ge ffnete T ren und Fenster Austrittsluft des Heizl fters usw gesch tzt montieren Wenn ein separater Raumf hler gew...

Страница 30: ...lm igen Wiederholungen Interner Fehler Leiterplatten berwachung Zweimaliges Blinken in regelm igen Wiederholungen DE Anhang A Sortiments bersicht Typ AW13 AW23 AW43 AW63 Spannung Frequenz 230 V 50 60...

Страница 31: ...mperatur von 18 C Die Wurfweite ist definiert als Abstand zwischen dem Heizl fter bis zu dem Punkt an dem die Luftgeschwindigkeit 0 2 m s betr gt 3 Der Luftstrom bei Drehzahl niedrig mittel hoch bei E...

Страница 32: ...AWLH AWT AWW AW AWPF Bilaga B Appendix B Anlage B A min B min C min D E mm mm mm mm mm AW 13 235 850 935 260 340 AW 23 250 850 950 330 410 AW 43 275 900 965 420 505 AW 63 265 900 920 550 640 Type Bil...

Страница 33: ...AW 13s 63s 13a 63a 33 Bilaga D Appendix D Anlage D...

Страница 34: ...AW 13s 63s 13a 63a 34 Bilaga E Appendix E Anlage E...

Страница 35: ...AW 13s 63s 13a 63a 35 Bilaga F Appendix F Anlage F...

Страница 36: ...AW 13s 63s 13a 63a 36 Bilaga G Appendix G Anlage G...

Страница 37: ...AW 13s 63s 13a 63a 37 Bilaga H Appendix H Anlage H...

Страница 38: ...AW 13s 63s 13a 63a 38 Bilaga I Appendix I Anlage I...

Страница 39: ...AW 13s 63s 13a 63a 39 Bilaga J Appendix J Anlage J...

Страница 40: ...AW 13s 63s 13a 63a 40 Bilaga K Appendix K Anlage K...

Страница 41: ...AW 13s 63s 13a 63a 41 Bilaga L Appendix L Anlage L...

Страница 42: ...AW 13s 63s 13a 63a 42 Bilaga M Appendix M Anlage M...

Страница 43: ...AW 13s 63s 13a 63a 43 Bilaga N Appendix N Anlage N...

Страница 44: ...ing 6 8 6 9V varvtal 800rpm luftm ngd 2000 m h AT Daikin 20 Styrsp nning 10V varvtal 1085rpm luftm ngd 3500 m h Control voltage speed fanmotor and air volume AT Daikin 12 Control voltage 6 8 6 9V spee...

Страница 45: ...AW 13s 63s 13a 63a 45...

Страница 46: ...AW 13s 63s 13a 63a 46...

Страница 47: ...AW 13s 63s 13a 63a 47...

Страница 48: ...o the contents of this manual without prior notice VEAB Heat Tech AB Stattenav gen 50 S 281 33 H ssleholm SWEDEN Delivery adress ngdalav gen 4 Org no F skatt 556138 3166 VAT no SE556138316601 Postal C...

Отзывы: